Browse Categories

3M(TM) Hot Melt Applicator PG II and PG II LT Valve Assembly Kit 9223, 1 per case

21703 VALVE ASSEMBLY KIT
Item #: 83182421

Product Info

21703
3M

21703 VALVE ASSEMBLY KIT
3M(TM) Hot Melt Applicator PG II and PG II LT Valve Assembly Kit 9223, 1 per case

The Zeta Plus™ BC Series Filter Capsule with LA Series Media comprises a mixture of high surface area inorganic particles, cellulose, and a positively charged crosslinking polymer. These filters have a reduced potential of yielding false positives in drug product endotoxin testing resulting from 1,3 beta-glucan interference in LAL (Endotoxin) assays. They are designed for the lowest organic and inorganic extractable levels of the 3M depth filter portfolio by aggressively extracting both the inorganic particles and cellulose fibers. The combination of filtration efficiency and throughput results from the balance between porosity and depth, and the relatively low level anion exchange capacity: removing some negatively charged soluble and submicron particles via anion exchange, and larger particles by mechanical sieving.

The BC25 laboratory capsule is ideal for optimizing the filtration performance for each drug process by effectively screening the breadth of available single and dual layer media options. A scalable range of single-use capsules enables predictable performance at every stage of drug development from early stage discovery to commercial production.

Pharmaceutical Grade Product
The Zeta Plus™ LA Series Filter products are specifically designed for use in the manufacture of biopharmaceutical, vaccine, blood fractionation and small molecule API drug substances. The effluent characteristics of the Zeta Plus LA Series Filter media and capsules has been tested following a number of protocols contained in the United States Pharmacopeia (USP) compendia.

The Zeta Plus LA Series filter media is specifically designed to have the lowest organic and inorganic extractable levels of the entire 3M depth filter portfolio. Stringent product extractable specifications are controlled, in part, by aggressively extracting both the cellulose fibers and filter aids prior to producing the filtration media. Due to the pre-extraction of the cellulose fibers, the Zeta Plus LA Series filtration media has a reduced potential of yielding false positives in product endotoxin testing resulting from 1,3 beta-glucan interference in LAL assays.

The 3M Purification Inc. Quality Management System is approved by an accredited registering body to the ISO 9001:2008 and ISO 13485:2003 Quality Management Systems. The manufacturing process, quality controls and regulatory oriented compliance reports are documented in a Drug Master File on record with the FDA.

Filtration Performance
Zeta Plus LA Series filter media comprises a mixture of high surface area inorganic particles, high surface area cellulose and a crosslinking polymer resin. The polymer resin has a positive charge as a result of a balance of secondary, tertiary and quaternary amines resulting in a relatively low anion exchange capacity. As such, Zeta Plus™ LA Series filters are a good choice in applications where the pharmaceutical product is negatively charged and product recovery may be of concern. By controlling the choice of raw materials and the formulation, a variety of filtration grades are produced that each have a balance of fine particle removal and throughput capacity.

Single-use Capsules
Ease of use, operating costs and development time may all be improved by using 3M’s single-use capsules. Specifically, singleuse capsules may reduce batch-to-batch change over time, minimize the time required to develop and manage complex validated equipment cleaning protocols and reduce the large cleaning fluid volume demands of a production operation.

The Zeta Plus™ LA S

  • Designed to have the lowest organic and inorganic extractable levels in the 3M depth filter portfolio
  • Stringent product extractable specifications enabled by both pre-extracting of both cellulose fiber and filter aid
  • Reduced potential of 1,3 beta-glucan interference in product endotoxin testing based on the use of aggressively extracted cellulose fibers
  • Filtration performance optimized to a broad range of fluid challenges
  • Full range of scalable single-use capsules enables predictable performance at every stage of drug development from early stage discovery to commercial production
ApplicationPlasma Fractionation
Component and Assembly MaterialsCellulose
Effective Filtration Area25 cm²
End ModificationLuer
Filter MaterialCellulose
Filter TechnologyAdsorbent
Filter TypeDepth
Flow Rate (Imperial)25 GPM
Grade90LA
Maximum Operating Temperature (Celsius)40 Degree Celsius
Maximum Operating Temperature (Fahrenheit)104 Degree Fahrenheit
Micron Rating0 NP
Overall Diameter (Imperial)2.63 in
Overall Diameter (Metric)66.8 mm
Overall Width (Imperial)9.84 in
Overall Width (Metric)25 cm
Pressure Range40 psig
Pressure Range (Metric)2.8 bar
Product NumberBC0025L90LA
SeriesZeta Plus™ BC Series
ECCNEAR99