Southwire 55082415 Armored Cable Zenith AS110024C Speaker Wire Zenith AS105018C Speaker Wire
Wire whip, 14/3 AWG. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
Zenith AS105016C Speaker Wire Romex SIMpull 14/2NM-WGX25 Building Wire Zenith AS110018C Speaker Wire
Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
Armorlite 68580021 Type MC Armored Cable Armorlite 68579221 Type MC Armored Cable Romex SIMpull 12/2NM-WGX25 Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 14/3NM-WGX25 Building Wire Duraclad 55278321 Type MC Armored Cable Zenith AS105014C Speaker Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
Duraclad 55274921 Type MC Armored Cable Romex SIMpull 14/2NM-WGX50 Building Wire World Wide Sourcing 62100 Soap Dispenser
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Use for soap and/or other liquids. Quick and easy refills. Installs in/under kitchen sink or counter.
Alflex FO5000025M Type RWA Reduced Wall Flexible Conduit Alflex FO7500025M Type RWA Reduced Wall Flexible Conduit Mintcraft LB61 Lavatory Faucets
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Replaceable seat, stem and index buttons. 1/2" IPS inlets. Chrome plated brass. Boxed.
Danco 10037 Soap Dispenser with 48 in Hose Alflex FO3750050M Type RWA Reduced Wall Flexible Conduit Armorlite 68579222 Type MC Armored Cable
Straight spout.  Long shank fits any counter top, Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
PlumbPak PP4801 Soap/Lotion Dispenser PlumbPak PP4801W Soap/Lotion Dispenser DANCO 10038 Soap Dispenser
Fast, easy refill from top of dispenser. Fast, easy refill from top of dispenser. Curved spout. Long shank fits any counter top,
DANCO 10039 Soap Dispenser Armorlite 68583421 Type MC Armored Cable Duraclad 55274922 Type MC Armored Cable
Straight spout.  Long shank fits any counter top, Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Duraclad 55278521 Type MC Armored Cable Southwire UO5000025M Liquid Tight Flexible Conduit DANCO 10042 Soap Dispenser
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Long Shank fits any counter top,
DANCO 10040 Soap Dispenser Keeney K612DSBN Soap/Lotion Dispenser Duraclad 55275021 Type MC Armored Cable
Long Shank fits any counter top, Premium clear plastic reservoir bottle. Metal fill rod. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Romex SIMpull 10/2NM-WGX25 Building Wire Armolite 68580022 Solid Metal Clad Cable Romex SIMpull 12/3NM-WGX25 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 14/2NM-WGX100 Building Wire Romex SIMpull 12/2NM-WGX50 Building Wire Keeney K612VB Soap/Lotion Dispenser
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Premium clear plastic reservoir bottle. Metal fill rod.
Romex SIMpull 14/3NM-WGX50 Building Wire Duraclad 55278322 Type MC Armored Cable Alflex FO5000050M Type RWA Reduced Wall Flexible Conduit
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
PlumbPak PP612DSBN Soap/Lotion Dispenser Alflex FO37501001 Type RWA Reduced Wall Flexible Conduit Alflex FO7500050M Type RWA Reduced Wall Flexible Conduit
PlumbPak Soap/Lotion Dispenser, Premium, Series: PP612DSBN, Brushed Nickel Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Romex SIMpull 14/2NM-WGX250 Building Wire Armolite 68583422 Solid Metal Clad Cable Romex SIMpull 10/3NM-WGX25 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/2NM-WGX100 Building Wire Southwire UO7500025M Liquid Tight Flexible Conduit Armolite 68580023 Solid Metal Clad Cable
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
WIRE BUILDING 8/3NM-B W/G 25FT Alflex FO75001001 Type RWA Reduced Wall Flexible Conduit Duraclad 55278323 Type MC Armored Cable
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Duraclad 55274923 Type MC Armored Cable Romex SIMpull 12/3NM-WGX50 Building Wire Southwire UO5000050M Liquid Tight Flexible Conduit
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
Alflex FO50001001 Type RWA Reduced Wall Flexible Conduit Romex SIMpull 14/3NM-WGX100 Building Wire Romex SIMpull 10/2NM-WGX50 Building Wire
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/2NM-WGX250 Building Wire WIRE BUILDING 6/3NM-B W/G 25FT Romex SIMpull 14/3NM-WGX250 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Peerless P188720 Tub/Shower Faucet TUB/SHWR ST PRES/BAL PLSH CHM American Standard Jocelyn Tub and Shower Faucet
Includes both metal lever and acrylic knob handles to match any decor. Pressure balance valve keeps water temperature within +/-3 degrees F. ADA Compliant. Flow Rate: 2.0 gpm @ 60 psi, 7.6 L/min @ 414 kPa. Cast brass body, washerless ceramic disc valve cartridge with back-to-back capability and hot limit safety stop. Cycles from off to hot through cold. Pressure balancing cartridge maintains constant output temperature in response to changes in relative hot and cold supply pressure. 1/2" female IPS inlets and outlets, easy clean showerhead with 2.5 gpm flow restrictor, rough-in plaster guard designed for use as thin-wall mounting adapter. Cast brass body, washerless ceramic disc valve cartridge with back-to-back capability and hot limit safety stop. Cycles from off to hot through cold. Pressure balancing cartridge maintains constant output temperature in response to changes in relative hot and cold supply pressure. 1/2" female IPS inlets and outlets, easy clean showerhead with 2.5 gpm flow restrictor, rough-in plaster guard designed for use as thin-wall mounting adapter. Lifetime Warranty.
Armolite 68583423 Solid Metal Clad Cable Coleman 946016618 Speaker Wire Romex SIMpull 10/3NM-WGX50 Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Parallel wire, power limited circuit cable, -20 Celsius to 105 Celsius. Used for stereos and hi-fi systems, home theater sound systems, lamps, and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL Type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Southwire UO7500050M Liquid Tight Flexible Conduit TUB/SHOWER SET PRES/BAL BN    Moen Adler Tub/Shower Faucet
Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Cast brass body, washerless ceramic disc valve cartridge with back-to-back capability and hot limit safety stop. Cycles from off to hot through cold. Pressure balancing cartridge maintains constant output temperature in response to changes in relative hot and cold supply pressure. 1/2" female IPS inlets and outlets, easy clean showerhead with 2.5 gpm flow restrictor, rough-in plaster guard designed for use as thin-wall mounting adapter. Chrome-plated metal lever handle, valve, showerhead, arm, flange, and tub spout. 1/2" IPS connections. Pressure balancing cycle valve design with an adjustable temperature limit stop, maintains selected discharge temperature to +/-2 degrees. Showerhead limited to 2.0 gpm (9.5 L/min). 1222 design cartridge, of nonmetallic/nonferrous and stainless steel materials. Accommodates back-to-back installations. Meets CSA, ASME/ANSI requirements.  ADA Compliant.
American Standard Winthrop Tub and Shower Faucet Romex SIMpull 12/3NM-WGX100 Type NM-B Building Wire Delta Monitor Tub/Shower Faucet
Cast brass body, washerless ceramic disc valve cartridge with back-to-back capability and hot limit safety stop. Cycles from off to hot through cold. Pressure balancing cartridge maintains constant output temperature in response to changes in relative hot and cold supply pressure. 1/2" female IPS inlets and outlets, easy clean showerhead with 2.5 gpm flow restrictor, rough-in plaster guard designed for use as thin-wall mounting adapter. Lifetime Warranty. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Single lever handle pressure balance tub and shower faucet. Pressure balance valve ensures bathing water remains a consistent temperature through any change in water pressure and prevents scalding with an internal limit-stop that prevents water temperatures from rising to a dangerous level. Includes showerhead, arm, flange, and tub spout with diverter. Solid brass construction and brass waterways. ADA certified. Lifetime limited faucet and finish warranty. Chrome finish.
Duraclad 55278301 Type MC Armored Cable Duraclad 55274901 Type MC Armored Cable WIRE BUILDING 8/3NM-B W/G 50FT
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C.
Armorlite 68580001 Type MC Armored Cable Peerless P188775 Tub/Shower Faucet Romex SIMpull 10/2NM-WGX100 Type NM-B Building Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Pressure balance valve keeps water temperature within +/-3 degrees F. Includes MultiChoice Valve which allows for upgrade to Dual-Function shower trim and cartridge, ADA Compliant. Flow Rate: 2.0 gpm @ 60 psi, 7.6 L/min @ 414 kPa. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Coleman 600006621 SPT-1 Lamp Cord Coleman 600006619 SPT-1 Lamp Cord Coleman 600006607 SPT-1 Lamp Cord
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 600006608 SPT-1 Lamp Cord Coleman 600006618 SPT-1 Lamp Cord Coleman 600006601 SPT-1 Lamp Cord
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Peerless P188775-BN Tub/Shower Faucet Southwire UO500001001 Liquid Tight Flexible Conduit Romex SIMpull 8/2NM-WGX125 Type NM-B Building Wire
Pressure balance valve keeps water temperature within +/-3 degrees F. Includes MultiChoice Valve which allows for upgrade to Dual-Function shower trim and cartridge, ADA Compliant. Flow Rate: 2.0 gpm @ 60 psi, 7.6 L/min @ 414 kPa. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Delta Faucet 144984 Tub/Shower Faucet Delta Faucet 144996 Tub/Shower Faucet Romex SIMpull 12/3NM-WGX250 Type NM-B Building Wire
Tub and shower trim. Single-function pressure balanced cartridge, 2.0 gpm at80 psi. Full body spray, massaging spray, soft drench spray. Solid brass forged body, AD compliant, WaterSense labeled. Monitor14 Series pressure balanced bath mixing valve with Scald-Guard. Solid brass forged body, MultiChoice Universal rough valve body included. ADA compliant, WaterSense labeled. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Coleman 553046607 Type CL-2 Electrical Wire Romex SIMpull 28827472 Type NM-B Building Wire Moen Banbury Tub and Shower Faucet
Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Chrome finish, lever design, PosiTemp pressure-balancing valve maintains water pressure and controls temperature, 1/2" IPS connection, 2.0 gpm max.
Coleman 94605M418 Type CL-2 Speaker Cable Delta Monitor 1343 Tub/Shower Trim Delta Monitor Tub/Shower Faucet
Parallel wire, power limited circuit cable, -20 Celsius to 105 Celsius. Used for stereos and hi-fi systems, home theater sound systems, lamps, and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL Type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. Pressure balanced single handle bath mixing valve. Requires 1-1/2" wall cavity. Back-to-back installation capability. Solid brass fabricated body. Monitor with Scald-Guard valve maintains a balanced pressure of hot and cold water even when a valve is turned on or off elsewhere in the system. Lever handle. Temperature only controlled with handle. Field adjustable to limit handle rotation into hot water zone. 120 degree maximum handle rotation. All parts are replaceable from the front of the valve. Easy-to-clean, Touch-Clean showerhead provides full-spray pattern. Pull-up diverter spout for easy shower operation. Complies with ASME A112.18.1M-1996, ASSE 1016-1996, CSA B125-93, Showerhead: GSA A-A-240, ASSE seal authorized, City of L.A. approved, CSA certified, and IAPMO listed. ADA compliant. Crystal-like handle. Supplied with a break-away tab in valve body, which allows stem to be reversed, allowing reverse piping application. Temperature only controlled with handle. 1/2" IPS inlets. Monitor Scald-Guard valve keeps water temperature within +/-3Degrees F.
American Standard 9046502.181 Tub/Shower Faucets Southwire UO75001001 Liquid Tight Flexible Conduit Romex SIMpull 10/3NM-WGX100 Type NM-B Building Wire
Cast brass body, washerless ceramic disc valve cartridge with back-to-back capability and hot limit safety stop. Cycles from off to hot through cold. Pressure balancing cartridge maintains constant output temperature in response to changes in relative hot and cold supply pressure. 1/2" female IPS inlets and outlets, easy clean showerhead with 2.5 gpm flow restrictor, rough-in plaster guard designed for use as thin-wall mounting adapter. Lifetime Warranty. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Barostat 553026607 Solid Type CL-2 Thermostat Cable FAUCET 1 HANDLE CHROME GIBSON Coleman 601266607 SPT-2 Lamp Cord
Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved. 4-1/2" diameter spray ahead, 6-1/2 tub spout, chrome finish, lever handle, equipped with the PosiTemp pressure?balancing control valve to help maintain water temperature in the shower. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 601266608 SPT-2 Lamp Cord Coleman 601266601 SPT-2 Lamp Cord Romex SIMpull 10/2NM-WGX250 Type NM-B Building Wire
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
WIRE BUILDING 6/3NM-B W/G 50FT Delta Monitor Tub/Shower Trim Moen 82830EP Tub/Shower Faucet
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Monitor 14 series pressure balanced bath mixing valve, universal rough valve body included, maintains a balanced pressure of hot and cold water even when a valve is turned on or off elsewhere in the system. Solid brass forged body. PosiTemp pressure-balancing control valve, 6" diameter spray head, 6" tub spout, complies with ADA specifications. 2.0 gpm.
Barostat 553056607 Solid Type CL-2 Thermostat Cable Moen Banbury Tub/Shower Faucet Coleman 94607M418 Type CL-2 Speaker Cable
Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved. One handle tub and shower faucet with Posi-Temp pressure balancing valve. Metal construction with 1/2" IPS connections. Boxed. 2.0 gpm. Parallel wire, power limited circuit cable, -20 Celsius to 105 Celsius. Used for stereos and hi-fi systems, home theater sound systems, lamps, and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL Type CL2, UL1581 and UL13 approved. Clear jacket, on a spool.
Romex SIMpull 6/2NM-WGX125 Type NM-B Building Wire Coleman 946036618 Speaker Cable Romex SIMpull 8/3NM-WGX125 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Two bare copper conductors laid flat with integral PVC insulation and jacket. Clear jacket construction has one bare copper and one tinned copper conductor. Temperature rated from -20 to 60 degrees C, operating voltage 300 volts maximum. 18/2 stranded, flat, boxed. UL Standard 13 & 444, CSA C22.2 No. 214, NEC Article 725 & 800.. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Moen Caldwell PosiTemp 82496EPBRB Tub/Shower Faucet Romex SIMpull 28828272 Type NM-B Building Wire Armorlite 68583401 Type MC Armored Cable
Posi-temp tub/shower faucet, Diverter spout, one-function showerhead, 1/2" IPS connection, 1222 one-piece washerless cartridge. Rubbed Bronze finish. 2.0 gpm. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Romex SIMpull 14/2NM-WGX1000 Type NM-B Building Wire Moen 82830EPSRN Tub/Shower Faucet Romex SIMpull 63946872 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. PosiTemp pressure-balancing control valve, 6" diameter spray head, 6" tub spout, complies with ADA specifications. 2.0 gpm. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 12/2NMW/GX500FT Type NM-B Building Wire Romex SIMpull 63947672 Type NM-B Building Wire Delta Monitor Tub/Shower Trim
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Monitor 14 series pressure balanced bath mixing valve, universal rough valve body included, maintains a balanced pressure of hot and cold water even when a valve is turned on or off elsewhere in the system. Solid brass forged body.
Barostat 553036607 Solid Type CL-2 Thermostat Cable Coleman 5407 Bell Wire Delta Faucet 14478-SSSHL Tub/Shower Faucet
Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved. Type CL2 low voltage cable using thermoplastic insulated solid conductors. Resistant to the spread of fire in accordance with NEC. Not for riser, plenum, or tray uses and 60 degrees Celsius. Use for thermostat control, burglar alarms, intercoms and doorbells. Soft annealed solid copper per ASTM B3-90 conductor. PVC insulation and UL13 approved for power limited circuit cable for other than plenum, riser, or tray uses. 150 volt. Single function operation - single lever handle for ease of temperature control. Easy to clean, Touch-Clean shower head with full spray function. 5 1/2" long pull-up diverter tub spout for added shower convenience. ADA Compliant, WaterSense labeled.
Southwire 65676902 Electrical Wire Romex SIMpull 10/3NM-WGX250 Type NM-B Building Wire Delta Monitor Tub/Shower Trim
ETL Listed type CL2 power limited circuit cable is a general-purpose 8 conductor low voltage control cable. Construction provides solid uncoated copper conductors insulated with polyvinyl chloride (PVC) insulation twisted together without filler and covered with an ETL listed sunlight resistant PVC jacket. Conductor colors are red, white, green, blue, yellow, brown, orange and black. Used for air conditioning controls, heat pumps, heating controls, thermostats and bell and alarm systems. For use in accordance with the NEC Article 725. Rated 60 degrees Celsius continuous in air. Solid 18/8 type CL2. Meets UL 1581 vertical flame tray test. 15 mil jacket thickness, approximately 202 mil overall cable diameter. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Temperature controlled with dial, volume controlled with handle. Red/blue handle indicators. 2.5 GPM at 80  psi from showerhead. Monitor Scald-Guard valve keeps water temperature within +/-3 degrees F.
Romex SIMpull 63949272 Type NM Building Wire Romex SIMpull 63948472 Type NM-B Building Wire Coleman 553076607 Type CL-2 Solid Thermostat Cable
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved.
Romex SIMpull 6/3NM-WGX125 Type NM-B Building Wire Romex SIMpull 12/2NM-WGX1000 Type NM-B Building Wire Coleman 5408 Bell Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type CL2 low voltage cable using thermoplastic insulated solid conductors. Resistant to the spread of fire in accordance with NEC. Not for riser, plenum, or tray uses and 60 degrees Celsius. Use for thermostat control, burglar alarms, intercoms and doorbells. Soft annealed solid copper per ASTM B3-90 conductor. PVC insulation and UL13 approved for power limited circuit cable for other than plenum, riser, or tray uses. 150 volt.
Romex SIMpull 28829072 Type NM-B Building Wire Romex SIMpull 63950072 Type NM-B Building Wire Barogation 547070408 Solid Sprinkler Cable
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Underground sprinkler system wire. 18/7 solid, 30 volts RMS max. Used for sprinkler control systems. Soft annealed solid copper per ASTM B3-90. Polyethylene insulation and jacket. 18 AWG bare copper. Cable consists of 7 bare copper insulated conductors with an overall outer jacket diameter of 0.268; UL listed.
Romex SIMpull 8/2NM/WG 500 FT Type NM-B Building Wire Romex SIMpull 14/3NM-WGX1000FT Type NM-B Building Wire Romex SIMpull 12/3NM-WGX1000FT Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 10/2NM-WGX1000 Type NM-B Building Wire Romex SIMpull 6/2NM-WGX500 Type NM-B Building Wire Romex SIMpull 8/3NM-W/GX500 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Southwire 12/2X500 W/G Quartz Single Ended Electrical Wire Romex SIMpull 10/3NM-WGX1000FT Type NM-B Building Wire Southwire 12/3X500 W/G Electrical Wire
Pump cable, type THW, thermoplastic (PVC) insulated, 600 volt. All wire insulated. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Pump cable, type THW, thermoplastic (PVC) insulated, 600 volt. All wire insulated.
Romex SIMpull 6/3NM-W/GX500 Type NM-B Building Wire Southwire 10/3X500 W/G Twisted Electrical Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Pump cable, type THW, thermoplastic (PVC) insulated, 600 volt. All wire insulated.
   
 