BUILDING WIRE / NM BUILDING WIRE / THHN BUILDING WIRE / UF
ENTRANCE CABLE ARMORED CABLE GROUND WIRE
LAMP CORD SJ CORD SPECIALTY WIRE
Sort By:
1
Carlon 12005-UPC Flexible Raceway Carlon 12007-UPC Flexible Raceway CONDUIT NON-MET FLEX 1/2 X 25
Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed. Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed. For the installation and protection of electrical conductors in circuits of 600 volts or less. Manufactured with a spiral of rigid PVC reinforcement imbedded within a flexible PVC wall. Impact and crush resistant, liquid tight and highly flexible. UV sunlight resistant jacket. Rated for temperature range of -30 to 80 degrees C , 60 degrees C Oil (-22 to +176, 140 degrees F Oil). UL Listed.
Thomas & Betts 150DRB Liquidtight Flexible/Non-Metallic Conduit Kit Southwire 55189401 Liquid Tight Flexible Whip Thomas & Betts 150ERB-UPC Liquidtight Flexible/Non-Metallic Conduit Kit
Contains everything necessary for complete installation including 6' conduit, two straight fittings and one 90 degree fitting. Totally non-metallic system provides assured grounding for safety. Non-conductive, non-corrosive. Easy to install. UL Listed components. Resistant to rust, cracks, and separation. Constructed with two different PVC materials. 600 volt stranded copper THHN/THWN conductors and UL Listed LFNC-B fittings. Twelve-inch wire leads are left exposed at each end. Green insulated copper grounding conductor. Intended for 208/240/480 volt. UL / CSA, complies with NEC Article 356. Contains everything necessary for complete installation including 6' conduit, two straight fittings and one 90 degree fitting. Totally non-metallic system provides assured grounding for safety. Non-conductive, non-corrosive. Easy to install. UL Listed components.
Southwire 55189301 Liquid Tight Flexible Whip B & K 120-004NL Drinking Water Faucet Ultratite 55094321 Liquid Tight Flexible Conduit
Resistant to rust, cracks, and separation. Constructed with two different PVC materials. 600 volt stranded copper THHN/THWN conductors and UL Listed LFNC-B fittings. Twelve-inch wire leads are left exposed at each end. Green insulated copper grounding conductor. Intended for 208/240/480 volt. UL / CSA, complies with NEC Article 356. Features touch release or continuous flow modes. Has both 1/4" and 3/8" compression inlet connections. For the installation and protection of electrical conductors in circuits of 600 volts or less. Manufactured with a spiral of rigid PVC reinforcement imbedded within a flexible PVC wall. Impact and crush resistant, liquid tight and highly flexible. UV sunlight resistant jacket. Rated for temperature range of -30 to 80 degrees C , 60 degrees C Oil (-22 to +176, 140 degrees F Oil). UL Listed.
World Wide Sourcing 62100 Soap Dispenser Mintcraft LB61 Lavatory Faucets Danco 10037 Soap Dispenser with 48 in Hose
Use for soap and/or other liquids. Quick and easy refills. Installs in/under kitchen sink or counter. Replaceable seat, stem and index buttons. 1/2" IPS inlets. Chrome plated brass. Boxed. Straight spout.  Long shank fits any counter top,
Keeney K612DSBN Soap/Lotion Dispenser Keeney K612VB Soap/Lotion Dispenser PlumbPak PP4801 Soap/Lotion Dispenser
Premium clear plastic reservoir bottle. Metal fill rod. Premium clear plastic reservoir bottle. Metal fill rod. Fast, easy refill from top of dispenser.
PlumbPak PP4801W Soap/Lotion Dispenser DANCO 10038 Soap Dispenser DANCO 10039 Soap Dispenser
Fast, easy refill from top of dispenser. Curved spout. Long shank fits any counter top, Straight spout.  Long shank fits any counter top,
DANCO 10042 Soap Dispenser DANCO 10040 Soap Dispenser PlumbPak PP612DSBN Soap/Lotion Dispenser
Long Shank fits any counter top, Long Shank fits any counter top, PlumbPak Soap/Lotion Dispenser, Premium, Series: PP612DSBN, Brushed Nickel
Carlon 12007-100 Flexible Raceway B & K 123-005 Anti-Siphon Bathroom Faucet Carlon 15005-100 Liquid Tight Flexible Conduit
Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed. 3-3/8" centers, Code Pattern has gooseneck spout. Replaceable seats and stems. 3/4" IPS inlets. Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed.
B & K 126-006LT Self-Closing Spring Load Shower Valve Carlon 15007-100 Liquid Tight Flexible Conduit Carlon 12005-200 Flexible Raceway
Brass body, chrome plated, spring-loaded self-closing mechanism, heavy duty pull chain and clips, for indoor/outdoor use, replaceable stem, cam and spring mechanism. Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed. Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed.
B&K 126-015 Utility Shower Faucet With Soap Dish 50 in Spout Delta P188710 Single Handle Shower Faucet B & K 120-007NL Drinking Water Bubbler
Brass waterways, compression cartridge, 3" center, 1/2" IPS connections. 2.5 GPM at 80 PSI, Meets A112.18.1M. Assembled height 22.75". Pressure balance valve keeps water temperature within +/-3 degrees F. WaterSense labeled, ADA compliant. Flow Rate: 2.0 gpm @ 60 psi, 7.6 L/min @ 414 kP. Small, compact, with built-in stop and pressure regulator. Adjusts easily, cannot be squirted. Rugged construction with sanitary head. Ideal for installation of refrigerator coolers, lavatories and replacement of old bubblers.
Moen Adler Classic L82691 Shower Faucet Delta Monitor Classic 13 Single Handle Shower Faucet Carlon 15008-100 Liquid Tight Flexible Conduit
Chrome-plated metal showerhead, arm, flange, handle and tub/shower valve. Posi-Temp pressure-balancing cycle valve design with an adjustable temperature limit stop to control max hot water temperature and maintain selected discharge temperature to +/-2 degrees. Lever-style handle operates counterclockwise through a 270-degree arc with clockwise direction shut-off at 6 o'clock and max hot at 9 o'clock. 2.0 gpm (9.5 L/min) showerhead limit. 1222 design cartridge of nonmetallic/nonferrous and stainless steel materials, accommodates back-to-back installations. 1/2" IPS connections. Meets CSA B-125, ASME/ANSI requirements. ADA Compliant. Monitor 13 series pressure balanced bath mixing valve with Scald-Guard maintains a balanced pressure of hot and cold water even when a valve is turned on or off elsewhere in the system. For use with MultiChoice universal rough valve body. (R10000 Series), back-to-back installation capability, solid brass fabricated body, temperature only controlled with metal lever handle, field adjustable to limit handle rotation into hot water zone, 120 degree maximum handle rotation, all parts replaceable from the front of the valve. Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed.
Delta Monitor 1324 Shower Faucet Delta Monitor 1323 Single Handle Shower Faucet Carlon 15011-050 Liquid Tight Flexible Conduit
Crystal-like handle. Accepts shower head up-grades. Supplied with a break-away tab in valve body which allows stem unit to be reversed, allowing reverse piping applications. Temperature and volume controlled with handle. 1/2" IPS inlets. Pressure balanced single handle bath mixing valve. Requires 1-1/2" wall cavity. Back-to-back installation capability. Solid brass fabricated body. Monitor with Scald-Guard valve maintains a balanced pressure of hot and cold water even when a valve is turned on or off elsewhere in the system. Lever handle. Temperature only controlled with handle. Field adjustable to limit handle rotation into hot water zone. 120 degree maximum handle rotation. All parts are replaceable from the front of the valve. Easy-to-clean, Touch-Clean showerhead provides full-spray pattern. Pull-up diverter spout for easy shower operation. Complies with ASME A112.18.1M-1996, ASSE 1016-1996, CSA B125-93, Showerhead: GSA A-A-240, ASSE seal authorized, City of L.A. approved, CSA certified, and IAPMO listed. ADA compliant. Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed.
Moen Banbury 82912SRN Tub/Shower Faucet Southwire 6SOLX315BARE Solid Electrical Wire Southwire 8SOLX500BARE Solid Electrical Wire
Posi-temp shower faucet, 1/2" IPS connection, 1222 one-piece washerless cartridge. Classic brushed nickel finish. 2.0 gpm. Equipment and circuit grounding. Equipment and circuit grounding.
Southwire 6STRDX315BARE Stranded Electrical Wire Southwire 4STRDX200BARE Stranded Electrical Wire Southwire 4SOLX200BARE Solid Electrical Wire
Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems. Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems. Equipment and circuit grounding.
Southwire 2SOLX125BARE Solid Electrical Wire Southwire 10SOLX800BARE Linear Electrical Wire Southwire SEU Service Entrance Cable
Equipment and circuit grounding. Equipment and circuit grounding. Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius in wet or dry locations, 600 volt. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable Southwire SEU Service Entrance Cable Wire
Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius in wet or dry locations, 600 volt. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable Wire
Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable Southwire SER Service Entrance Cable Southwire 2-2-4-6X500AL USE In-Use Service Entrance Cable Wire
Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 degrees Celsius in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944, and NEC requirements. Used as a panel feed in multiple unit dwellings. May be used in wet or dry locations at temperatures not to exceed 90 degrees Celsius. 600 volt maximum. Meets or exceeds UL Standard 44 for type XHHW-2 conductors or UL Standard 83 for THHN/THWN conductors, UL Standard 854, Federal Specification A-A59544, NEC requirements. Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact stranded 8000 series aluminum alloy. 600 volt. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 degrees Celsius. Quadruplex cable conductor construction. UL Listed.
Southwire SEU Service Entrance Cable Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable
Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 degrees Celsius in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944, and NEC requirements. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 degrees Celsius in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944, and NEC requirements.
Southwire MBL Service Entrance Cable Wire Southwire SER Service Entrance Cable Southwire SEU 13084905 Service Entrance Cable Wire
Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact stranded 8000 series aluminum alloy. 600 volt. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 degrees Celsius. Quadruplex cable conductor construction. UL Listed. Used as a panel feed in multiple unit dwellings. May be used in wet or dry locations at temperatures not to exceed 90 degrees Celsius. 600 volt maximum. Meets or exceeds UL Standard 44 for type XHHW-2 conductors or UL Standard 83 for THHN/THWN conductors, UL Standard 854, Federal Specification A-A59544, NEC requirements. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
   
 