Home > PLUMBING > KITCHEN & BATH > FAUCETS > LAVATORY FAUCETS - DUAL HANDLE
Sort By:
1
Halex 91530 Combination Coupling Halex 90510 Twin Screw Clamp Connector Halex 96510 2-Piece Butterfly Clamp Connector
Zinc die cast. Use to join EMT conduit to non-metallic sheathed cable. #14/2, #12/3 or 2 #14/2. Indoor use only. With UPC. UL Approved. Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements. Zinc die cast. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required.
Halex 90512 Twin Screw Clamp Connector Halex 27511 Hit Lock Cable Connectors Halex 90513 Twin Screw Clamp Connector
Fits non metallic cable, such as Romex, number 14/2 round, number 12/3-8/3 AWG or flex cord .460 to .720 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified. Fits non metallic cable number 14/2 to number 6/3 AWG or number 3/10/3 AWG or flex cord .450 to .730 inches diameter. With a 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements.
Cooper 1465Y-SP Adjustable Lamp Guard Halex 20511 Twin Screw Clamp Connector Halex 90514 Twin Screw Clamp Connector
High strength, impact resistant thermoplastic. Easy open guard permits relamping without removing guard. Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements. Fits non metallic cable number 6/3 to number 2/3 AWG flex cord .800 to 1.350 inches diameter or SE cable 3 conductor or 3 number 1/0 minimum; 3 conductor or 3 number 2/0 maximum. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements.
Halex 27519 Hit Lock Cable Connectors Halex 05115 Twin Screw Clamp Connector Halex 26512 2-Piece Butterfly Clamp Connector
Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified. Fits non metallic cable, flex cords, multi flex cords; fitting range .834 - 1.520 inches diameter SE cables 2 conductor 4/0. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Tray boxed. Zinc die cast. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required.
Halex 05120 Twin Screw Clamp Connector Halex 20510 Twin Screw Clamp Connector Halex 20512 Twin Screw Clamp Connector
Fits non metallic cable, flex cords, multi flex cords fitting range 1.085 - 1.520 inches diameter. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Tray boxed. Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements. Fits non metallic cable, such as Romex, number 14/2 round, number 12/3-8/3 AWG or flex cord .460 to .720 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements.
Powerzone PZ-200 Clamp Light Coleman 328 Clamp Light Powerzone PZ-300 Clamp Light
Ball joint for easy positioning. Tough, no scratch clamp. Bulb not included. 6 ft. 18/2 SPT-2 cord. UL listed. Porcelain socket clamp without switch. Screw in a light bulb and clamp the socket where needed. 150 watts/125 volt. Ball joint for easy positioning. Tough, no scratch clamp. Bulb not included. 6 ft. 18/2 SPT-2 cord. UL listed.
Powerzone PZ-302 Brooder Clamp Light Southwire 55082415 Armored Cable Zenith AS110024C Speaker Wire
Sturdy 10" aluminum reflector with guard grill. Ball joint for easy positioning. Tough, no scratch clamp and hang hook. 300 watt bulb maximum, not included. 6 ft. 18/2 SVT-2  cord. Wire whip, 14/3 AWG. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
Zenith AS105018C Speaker Wire Coleman 165 Brooder Lamp Zenith AS105016C Speaker Wire
Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Features insulated porcelain sockets, heavy gauge aluminum reflectors and hang-up hooks. Bulb guards that snap on the reflector, two-conductor, polarized male plugs and a durable vinyl cord. Used for pig and chicken brooders or as a temporary heat source. 10" reflector diameter. 250 watts/125 volt. UL, cUL Listed. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
Coleman 324 Clamp Light Woods 591 Flat SPT-2 Extension Cord Romex SIMpull 14/2UF-W/GX25 Building Wire
With bulb protector, sturdy anodized wire construction. Porcelain socket and clamp to hold the lamp in place. 150 watts/125 volt. Solid molded plugs and stranded all-copper conductors. Made with tough vinyl insulation that won't mark walls or floors and resists deterioration from moisture and abrasion. 13 amp/125 volt. Sleeved. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Halex 75105B Hit Lock Cable Connectors Power Zone PZ-1002 Portable Work Light Toolbasix PF4201A Lavatory Faucet
Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified. Tempered glass lens with metal safety grill. All weather 3 foot, 18/3 SJTW cord with molded plug. Spare bulb included. 4" centers. Washerless design, plastic waterways, water saving aerator, 1/2" 14NPSM inlet. Fits all standard basins. IAMPO & NSF certified, Carded.
Halex 27515 Cable Connectors Zenith AS110018C Speaker Wire LIGHT WAND LED
LIGHT WAND LED
Our Price: $16.54
Push-in style with captive locking wedge. Rigid PVC. Superior strain relief and insulation. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. Fits NM cable #14/2 - #10/3. Fits 1/2" knock outs. UL, CSA Listed. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Adjustable magnetic mounting bracket and motion sensor. Mode switch chooses between manual or motion sensor operation. Detaches from its bracket for hand-held use as a flashlight. 50 lumens, LEDs last 100,000 hours. Uses 3 AA batteries, (not included). Includes double-stick tape, screws and drywall anchors. 0.35 lb., 13"L x 1"D x 6"W.
Armorlite 68580021 Type MC Armored Cable Might-D-Light LED125C Mini Portable Work Light Toolbasix JY-4212PLQ Lavatory Faucet
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Compact folding LED work light with bungee hooks. 2 high powered LEDs generate up to 180 lumens. 3-way integrated switch: both panels on/single panel on and off. Hinge adjusts up to 270 degrees. Durable polycarbonate lenses. Bungee hooking mechanism attaches to hard to hang places. Extendable bungee hooks stow inside each panel for easy storage. Up to 4.5 hour battery life with 3 AA alkaline batteries, included. Fits all standard  basins, washerless design, water-saving aerator.
Woods 0831 Flat SPT-2 Extension Cord Armorlite 68579221 Type MC Armored Cable Coleman 2839 Clamp Light
Designed for general purpose indoor use. Features solid molded plugs and stranded all-copper conductors. Made of tough vinyl insulation that won't mark walls or floors and resists deterioration from moisture and abrasion. Yellow, sleeved. Rental. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Strong, vinyl coated spring clamp grips pipe, lumber and more. Aluminum 8-1/2" diameter reflector. Tough, heat resistant socket. Double swivel clamps with vinyl grips. Black cord. 150 watt/125 volt rating. UL, cUL Listed.
Toolbasix PF4201A-P Lavatory Faucet Toolbasix JY-4212PLQBN Lavatory Faucet Allied 103051 Rigid Conduit
4" centers. Washerless design, plastic waterways, water saving aerator, 1/2" 14NPSM inlet. Fits all standard basins. IAMPO & NSF certified, Carded. Fits all standard basins, washerless design, water-saving aerator. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1.
LIGHT LED WORK 1000LUM W/STAND Toolbasix PF4201RC Lavatory Faucet Duraclad 55278321 Type MC Armored Cable
LED work light with stand. 4" centers. Dual ABS round handles, ABS construction with matching ABS pop-up, plastic waterways, washerless cartridge, 1/2" 14NPSM inlet. IAMPO & NSF certified. Carded. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Zenith AS105014C Speaker Wire Duraclad 55274921 Type MC Armored Cable Romex SIMpull 12/2UF-W/GX25 Building Wire
Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
B & K 120-004NL Drinking Water Faucet Toolbasix PF4203A Laundry/Tub Faucet Allied 103069 Rigid Conduit
Features touch release or continuous flow modes. Has both 1/4" and 3/8" compression inlet connections. 4" centers. Dual acrylic round handles, ABS construction, plastic waterways, washerless cartridge, 1/2" 14NPSM inlet. IAMPO & NSF certified. Carded. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1.
CCI Contractor Portable Work Light With Switch WORKLIGHT AREA HARDCASE       Alflex FO5000025M Type RWA Reduced Wall Flexible Conduit
WORKLIGHT AREA HARDCASE
Our Price: $21.43
CCI Work Light, Portable, Series: Contractor, 120 V, 500 W, Halogen Lamp, 500 W Lamp, 1 Lamps, Corded Electric Power, 8000 lumens, 18/3 AWG Cord, 3 ft Cord Length, NEMA 5-15P Enclosure, 14 in Overall Height, Die Cast Metal, Powder Coated, Orange, Includes: Floor Stand With Handle, cUL, UL Listed, For Large Residential Construction Projects Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Coleman 169 Clamp Light FAUCET LAV 4IN 2HNDL ACRYL CHR Alflex FO7500025M Type RWA Reduced Wall Flexible Conduit
Aluminum 8-1/2" diameter reflector. Protective vinyl covered grips, full swivel head. Polarized. UL, cUL Listed. Acrylic round handle, durable metal construction, polymer waterway, washerless cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Halex 05112B Twin Screw Clamp Connector Halex 05103B Twin Screw Clamp Connector Mintcraft LB61 Lavatory Faucets
Fits non metallic cable number 6/3 to number 2/3 AWG flex cord .800 to 1.350 inches diameter or SE cable 3 conductor or 3 number 1/0 minimum; 3 conductor or 3 number 2/0 maximum. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements. Replaceable seat, stem and index buttons. 1/2" IPS inlets. Chrome plated brass. Boxed.
Woods 0592 Flat SPT-2 Extension Cord Peerless P240LF Lavatory Faucet Alflex FO3750050M Type RWA Reduced Wall Flexible Conduit
Solid molded plugs and stranded all-copper conductors. Made with tough vinyl insulation that won't mark walls or floors and resists deterioration from moisture and abrasion. 13 amp/125 volt. Sleeved. 3-hole, 4" centerset, washerless stem cartridge, 4" spout. Less pop-up. Drain not included. WaterSense labeled. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Romex SIMpull 14/2UF-WGX50 Building Wire FAUCET LAV 4IN 2HNDL ACRYL CHR Woods 0834 Flat SPT-3 Extension Cord
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Acrylic round handle, durable metal construction, polymer waterway, washerless cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. Designed for general purpose indoor use. Features solid molded plugs and stranded all-copper conductors. Made of tough vinyl insulation that won't mark walls or floors and resists deterioration from moisture and abrasion. Yellow, sleeved. Rental.
Armorlite 68579222 Type MC Armored Cable Toolbasix PF4233 Lavatory Faucet FAUCET LAUNDRY 4IN 2HNDL CHRM
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. 4" centers. Dual acrylic lever handles, and interchangeable chrome plated ABS handles included, ABS construction, matching ABS pop-up, plastic waterways, washerless cartridge, 1/2" 14NPSM inlet. IAMPO & NSF certified. Carded. Chrome, acrylic round handle, durable metal construction, polymer waterway, washerless cartridge, 1/2" 14NPSM inlet, 4" centers, 6" spout, IAMPO and NSF certified, extra threaded adaptor included.
Halex 05110B Twin Screw Clamp Connector Toolbasix PF4232 Lavatory Faucet Armorlite 68583421 Type MC Armored Cable
Fits non metallic cable number 14/2 to number 6/3 AWG or number 3/10/3 AWG or flex cord .450 to .730 inches diameter. With a 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. 4" centers. Dual acrylic lever handles, and interchangeable chrome plated ABS handles included, ABS construction, matching ABS pop-up, plastic waterways, washerless cartridge, 1/2" 14NPSM inlet. IAMPO & NSF certified. Carded. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Peerless P246LF Pop Up Lavatory Faucet LAMP CLAMP LED 1000 LUMEN     CCI Pro Portable Work Light With Hinged Style Face
LAMP CLAMP LED 1000 LUMEN
Our Price: $29.19
3-hole 4" centerset sink application, ergonomic blade handles offer easy control, pop-up drain included. CCI Work Light, Portable, Series: Pro, 600 W, Halogen Lamp, 300 W Lamp, 3 Lamps, 10800 lumens, 18/3 AWG Cord, 5 ft Cord Length, 8.2 in Overall Length, 5-1/2 in Overall Width, 12-1/2 in Overall Height, Die Cast Metal, Powder Coated, Red, cUL, UL Listed
B & K 125-001 Laundry Faucet Duraclad 55274922 Type MC Armored Cable Duraclad 55278521 Type MC Armored Cable
Heavy brass body, clamping type mounting with 3-3/8" center distance. Union inlets are combination 1/2" threaded or solder installations. Spout has 3/4" hose thread outlet. Replaceable seats and stems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Southwire UO5000025M Liquid Tight Flexible Conduit Woods 0832 Flat SPT-2 Extension Cord Allied 103077 Rigid Conduit
Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Designed for general purpose indoor use. Features solid molded plugs and stranded all-copper conductors. Made of tough vinyl insulation that won't mark walls or floors and resists deterioration from moisture and abrasion. Yellow, sleeved. Rental. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1.
Duraclad 55275021 Type MC Armored Cable Armolite 68580022 Solid Metal Clad Cable Toolbasix JY-4233BN Lavatory Faucet
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Fits all standard basins, washerless design, water-saving aerator.
B & K 225-503 Utility Laundry Faucet Halex 05107B Twin Screw Clamp Connector FAUCET LAV 4IN 2HNDL LEVER CHR
4" center distance, tubular spout with 3/4" hose thread outlet, replaceable seats and springs or washerless cartridge. 6" spout. Fits non metallic cable, such as Romex, number 14/2 round, number 12/3-8/3 AWG or flex cord .460 to .720 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. With plastic pop-up,, metal lever handle, durable metal construction, hybrid waterway, washerless cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi.
Power Zone PZ-1022 Work Light CCI Contractor 2-in-1 Adjustable Twin Head Work Light With Stand Halex 05703B Combination Clamp Connector
Floor stand. 40" tripod. 6', 16/3 SJW cord. UL listed. CCI Twin Head Work Light, 2-in-1, Adjustable, Series: Contractor, 120 V, 1000 W, Halogen Lamp, 500 W Lamp, 2 Lamps, Corded Electric Power, 20000 lumens, 18/3 AWG Cord, 5 ft Cord Length, NEMA 5-15P Enclosure, 63 in Overall Height, Die Cast Metal, Powder Coated, Orange, Includes: (2) Weatherproof Switch, cUL, UL Listed Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield, BX, NM or Metal Clad) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved.
Peerless P299232 Laundry Faucet FAUCET LAV 4IN 2HNDL ROUND CHR FAUCET LAV 4IN 2HNDL LEVER CHR
Dual knob handles for precise temperature control, Threaded spout end for easy hose attachment, 3-hole 4" centerset sink application. With plastic pop-up, chrome, metal round handle, durable metal construction, polymer waterway, washerless cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. With plastic pop-up, metal lever handle, durable metal construction, hybrid waterway, washerless cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi.
WORKLIGHT LED 1800L           Duraclad 55278322 Type MC Armored Cable Romex SIMpull 12/2UF-WGX50 Building Wire
WORKLIGHT LED 1800L
Our Price: $36.12
LED work light. Stays cool to the touch. 5x more energy efficient than Halogen lights. Sealed die-cast aluminum housing. Power cord with grounded plug. Long lasting super bright LEDs never need replacing. Adjustable tilt: 30 degrees down and 90 degrees up. Metal carrying handle. Sealed on/off switch. Indoor/outdoor approved. Impact resistant glass lens. 120V, 60 Hz, 5000K bright white. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 10/2UF-W/GX25 Type UF-B Building Wire Alflex FO5000050M Type RWA Reduced Wall Flexible Conduit B & K 123-005 Anti-Siphon Bathroom Faucet
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. 3-3/8" centers, Code Pattern has gooseneck spout. Replaceable seats and stems. 3/4" IPS inlets.
FAUCET LAV 2HANDLE CNTR CHROME WORK LIGHT LED 3000LUMEN      FAUCET LAV 4IN 2HNDL LEVER NIC
WORK LIGHT LED 3000LUMEN
Our Price: $39.21
WaterSense certification promotes water conservation. Includes matching finish drain assembly. 3-hole 4 in. installation. Standard spout. Stays cool to the touch. 5x more energy efficient than Halogen lights. Sealed die-cast aluminum housing. 5? power cord with grounded plug. Long lasting super bright LEDs never need replacing. Adjustable tilt: 30 degrees down and 90 degrees up. Cushioned metal carrying handle. Sealed on/off switch. Impact resistant glass lens. Metal base with rubber feet. 120V, 60 Hz, 5000K bright white. With plastic pop-up,, metal lever handle, durable metal construction, hybrid waterway, washerless cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi.
Romex SIMpull 14/3UF-WGX50 Type UF-B Building Wire Romex SIMpull 14/2UF-WGX100 Building Wire FAUCET LAV 4IN 2HNDL LEVER CHR
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. With plastic pop-up, chrome, metal ADA compliant handle, durable metal construction, polymer waterway, washerless cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi.
Alflex FO37501001 Type RWA Reduced Wall Flexible Conduit LIGHT WORK LED 1000 LUM TRIPOD Power Zone PZ-1005 Work Light
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Shatter-resistant polycarbonate lens. Cool to the touch. Powered by 6 foot AC Adapter, (110v to 240v). 15 watts, 1000 lumens, 4000K, 75 CRI, 120 degree beam width. Adjustable 6' tripod. Two 500 watt Halogen fixtures. Tempered glass lens with metal safety grill. All weather cord with polarized plug. Spare bulb included. 18/3 SJTW 6 foot cord. UL listed.
Alflex FO7500050M Type RWA Reduced Wall Flexible Conduit Allied 109085 Rigid Conduit American Standard Jocelyn Lavatory Faucet
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1. Centerset on 4" centers. 1/4 turn washerless ceramic disc valve cartridges. Durable cast brass waterways with 1/2" male inlet shanks. Metal body. Color matched underbody, metal lever handles, 20" flexible stainless steel drain cable pre-assembled to faucet body, non-metallic speed connect drain body with 1-1/4" tail piece. 1.5 gpm. Lifetime Warranty.
B & K 126-006LT Self-Closing Spring Load Shower Valve Armolite 68583422 Solid Metal Clad Cable FAUCET CNTST 2HDL PLSH CHM 4IN
Brass body, chrome plated, spring-loaded self-closing mechanism, heavy duty pull chain and clips, for indoor/outdoor use, replaceable stem, cam and spring mechanism. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Centerset on 4" centers. 1/4 turn washerless ceramic disc valve cartridges. Durable cast brass waterways with 1/2" male inlet shanks. Metal body. Color matched underbody, metal lever handles, 20" flexible stainless steel drain cable pre-assembled to faucet body, non-metallic speed connect drain body with 1-1/4" tail piece. 1.5 gpm.
WORK LGHT LED RECHARGABLE 900L Woods 0835 Flat SPT-3 Extension Cord Allied 103093 Rigid Conduit
Foldable rechargeable LED work light. High-capacity rechargeable battery, 7.4V Lithium-ion. Runs for 2 hours on high brightness and holds its charge for up to 18 months in storage. Light stays cool to the touch. Long lasting super bright LEDs never need replacing. 4 modes: high, medium, low and flashing. USB output for charging other portable devices. Head tilts 360 degrees. Indoor/outdoor approved. Includes 120V AC wall charger 12V DC car charger. 5000K bright white. 3 hours recharge time. Designed for general purpose indoor use. Features solid molded plugs and stranded all-copper conductors. Made of tough vinyl insulation that won't mark walls or floors and resists deterioration from moisture and abrasion. Yellow, sleeved. Rental. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1.
Southwire UO7500025M Liquid Tight Flexible Conduit WORK LIGHT LED 5000L          FAUCET 2HANDLE LOW ARC CHROME
WORK LIGHT LED 5000L
Our Price: $53.08
Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Sealed die-cast aluminum housing. 5? power cord with grounded plug. Long lasting super bright LEDs never need replacing. Adjustable tilt: 30 degrees down and 90 degrees up. Cushioned metal carrying handle. Sealed on/off switch. Impact resistant glass lens. Metal base with rubber feet. 120V, 60 Hz, 5000K bright white. Chrome finish is highly reflective for a mirror-like look that works with any decorating style, two-handle lever handles make it easy to adjust the water, 4" centerset design allows for easy installation, complies with Americans with Disabilities Act (ADA) specifications, meets EPA WaterSense criteria to conserve water without sacrificing performance, limited lifetime warranty, meets current legislation, including ab1953 (California) and s152 (Vermont) 1.5 gpm.
WORKLGHT LED MGNTC BS 900L 10W LIGHT LED WORK 2500LUM W/USB  Armolite 68580023 Solid Metal Clad Cable
Rechargeable LED work light with magnetic base. Sealed die-cast aluminum housing. 4 high-power neodymium magnets for mounting versatility. Long lasting super bright LEDs never need replacing. Adjustable tilt: 30 degrees down and 90 degrees up. Cushioned metal carrying handle. Separate mode selection switch: high, medium, low and flashing. Sealed on/off switch, impact-resistant glass lens. Reversible metal base, rubberized feet or magnetic. 7.4V Lithium-ion battery, 4.4 Ah. 3-5 hours recharge time. 2.1 lb. Includes 120V AC wall charger and 12V DC car charger. 10 watts, 5000K white light, 900/420/220 lumens. 3.5/6/12 hours run time per charge. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
B&K 126-015 Utility Shower Faucet With Soap Dish 50 in Spout FAUCET LAV 4IN 2HNDL LEVER NIC FAUCET CENTRST 2HDL STN NICKEL
Brass waterways, compression cartridge, 3" center, 1/2" IPS connections. 2.5 GPM at 80 PSI, Meets A112.18.1M. Assembled height 22.75". With plastic pop-up, metal lever handle, durable metal construction, hybrid waterway, washerless cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. Centerset on 4" centers. 1/4 turn washerless ceramic disc valve cartridges. Durable cast brass waterways with 1/2" male inlet shanks. Metal body. Color matched underbody, metal lever handles, 20" flexible stainless steel drain cable pre-assembled to faucet body, non-metallic speed connect drain body with 1-1/4" tail piece. 1.5 gpm.
FAUCET BTH 2-HNDL W/POP-UP CHM Alflex FO75001001 Type RWA Reduced Wall Flexible Conduit Moen Chateau Laundry Faucet
Metal lever handle. High spout. Ceramic cartridge. Easy install pop-up drain assembly. Water-saving aerator. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Chrome finish, 1/2" IPS connection, 2.2 gpm max., ADA compliant.
Duraclad 55278323 Type MC Armored Cable Delta Classic Kitchen Faucet Duraclad 55274923 Type MC Armored Cable
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Easy to operate blade handles, solid brass construction, 360 degree swivel spout, washerless stem cartridge, spout length: 4-5/8", spout total height: 7", 2 or 3-hole 4" installation. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Southwire UO5000050M Liquid Tight Flexible Conduit Romex SIMpull 12/3UF-WGX50 Type UF-B Building Wire Alflex FO50001001 Type RWA Reduced Wall Flexible Conduit
Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
American Standard Jocelyn Lavatory Faucet American Standard Winthrop Traditional Lavatory Faucet Peerless P299675LF Lavatory Faucet
Centerset on 4" centers. 1/4 turn washerless ceramic disc valve cartridges. Durable cast brass waterways with 1/2" male inlet shanks. Metal body. Color matched underbody, metal lever handles, 20" flexible stainless steel drain cable pre-assembled to faucet body, non-metallic speed connect drain body with 1-1/4" tail piece. 1.5 gpm. Lifetime Warranty. Centerset on 4" centers. 1/4 turn washerless ceramic disc valve cartridges. Durable cast brass waterways with 1/2" male inlet shanks. Metal body. Color matched underbody, metal lever handles, 20" flexible stainless steel drain cable pre-assembled to faucet body, non-metallic speed connect drain body with 1-1/4" tail piece. 1.5 gpm. Lifetime Warranty. 3-hole 4" centerset sink application, washerless stem cartridge, plastic pop-up drain included. ADA compliant. low Rate: 1.5 gpm @ 60 psi, 5.7 L/min @ 414 kPa. Spout Length: 4 17/32".
Delta 2502LF Classic Lavatory Faucet LIGHT WORK LED 1500LUM RECHRGE FAUCET LAV 2HANDLE CNTR CHROME
4" centerset. 2 hole installation. Crystal-like handles, knob. 1/2" IPS inlets. LED rechargeable area light. High/low switch, shatter-resistant polycarbonate lens. Cool to touch. 20 watts, 1500 lumens, 4000K. 120 degree beam width. WaterSense certification promotes water conservation. Includes matching finish drain assembly. Meets standards set by Americans with Disabilities Act (ADA).Washerless stem cartridge 3--hole 4 in. installation. 5 in. spout length.
CCI Pro 2-in-1 Twin Head Work Light With Telescoping Tripod Stand B & K 120-007NL Drinking Water Bubbler FAUCET BATH 2HNDL CHRM LOW ARC
CCI Twin Head Work Light, 2-in-1, Combo, Series: Pro, 130 V, 1200 W, 10 A, Halogen Lamp, 300 W Lamp, 5 Lamps, Electric Power, 21600 lumens, 1000 hr Average Life, Wide Angle Lens, 18/3 AWG Cord, 7 ft Cord Length, 25-1/2 in Overall Length, 31-1/8 in Overall Width, 70-1/2 in Overall Height, Die Cast Metal, Powder Coated, Red, cUL, UL Listed Small, compact, with built-in stop and pressure regulator. Adjusts easily, cannot be squirted. Rugged construction with sanitary head. Ideal for installation of refrigerator coolers, lavatories and replacement of old bubblers. Chrome finish, two-handle lever handles make it easy to adjust the water, 4" centerset, complies with Americans with Disabilities Act (ADA) specifications. 1.2 gpm.
Delta 2500LF Classic Lavatory Faucet Mintcraft PF6363204 Laundry Faucets FAUCET BTH 2-HDL W/POP-UP BNKL
4" centerset, 2 and 3 hole installation. Blade handles. 1/2" IPS inlets. 8" centers, 8" swing spout, convenient soap dish, dual metal handles, solid brass construction, solid brass waterways. 1/2" 14NPSM inlet. Replaceable seats and stems, adjustable flange. Boxed. Metal lever handle. High spout. Ceramic cartridge. Easy install pop-up drain assembly. Water-saving aerator.
Romex SIMpull 12/2UF-WGX100 Building Wire FAUCET LAV 4IN 2HNDL LEVER CHR Peerless P299695LF Lavatory Faucet
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. With plastic pop-up, metal lever handle, durable metal construction, hybrid waterway, ceramic cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. 3-hole 4" centerset sink application,washerless stem cartridge, High arc, rotating spout, plastic pop-up drain included. ADA compliant. Flow Rate: 1.5 gpm @ 60 psi, 5.7 L/min @ 414 kPa. Spout Length: 3-7/8".
FAUCET LAV 4IN 2HNDL LEVER CHR Allied 103101 Rigid Conduit WORK LIGHT W/TRIPOD LED 4200L
With plastic push on pop-up, metal lever handle, durable metal construction, hybrid waterway, ceramic cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1. Stays cool to the touch. 5x more energy efficient than Halogen lights. Sealed die-cast aluminum housing. 9? power cord with grounded plug. Long lasting super bright LEDs never need replacing. Adjustable tilt: 30 degrees down and 90 degrees up. Sealed on/off switch on each light. Impact resistant glass lens. Metal base. Quick-release system for detaching lights from tripod. 120V, 60 Hz, 5000K bright white.
Peerless P299696LF Lavatory Faucet FAUCET LAV 4IN 2HNDL LEVER NIC WORK LIGHT LED 7500L
WORK LIGHT LED 7500L
Our Price: $71.42
Ergonomic blade handles offer easy control, 3-hole 4" centerset sink application, pop-up drain included. With plastic pop-up, metal lever handle, durable metal construction, hybrid waterway, ceramic cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. Stays cool to the touch. 8x more energy efficient than Halogen lights. Sealed die-cast aluminum housing. 10? power cord with grounded plug. Long lasting super bright LEDs never need replacing. Adjustable tilt: 30 degrees down and 90 degrees up. Cushioned metal carrying handle. Sealed on/off switch. Impact resistant glass lens. Metal base with rubber feet. 120V, 60 Hz, 5000K bright white.
WORK LGHT LED RECHRGABLE 1800L Coleman 75488802 String Light Cord LIGHT LED WORK 4000LUM W/USB
Foldable rechargeable LED work light. High-capacity rechargeable battery, 7.4V Lithium-ion. Runs for 2 hours on high brightness and holds its charge for up to 18 months in storage. Light stays cool to the touch. Long lasting super bright LEDs never need replacing. 4 modes: high, medium, low and flashing. USB output for charging other portable devices. Head tilts 360 degrees. Indoor/outdoor approved. Includes 120V AC wall charger 12V DC car charger. 5000K bright white. 3 hours recharge time. Constructed with molded lamp sockets and non-metallic lamp guards. Each 150 watt light is 10' apart. 125 volt. Boxed.
FAUCET LAV 4IN 2HDL LEV BR NIC Romex SIMpull 14/2UF-W/GX250 Building Wire Delta Porter Lavatory Faucet
With plastic push on pop-up, metal lever handle, durable metal construction, hybrid waterway, ceramic cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. High arc design spout, metal lever handles, plastic pop-up drain, 4" centerset, washerless stem cartridge.
FAUCET BTHROOM CHM 2-HDL 8IN  FAUCET LAV 4IN 2HNDL LEVER BRZ Peerless P299675LF-BN Decorative Lavatory Faucet
Widespread faucet with 8" centers. 1/4 turn washerless ceramic disc valve cartridges. Durable cast brass waterways with 1/2" male inlet shanks. Metal body. Color matched underbody, metal lever handles, 20" flexible stainless steel drain cable pre-assembled to faucet body, non-metallic speed connect drain body with 1-1/4" tail piece. 1.5 gpm. Lifetime Warranty. With plastic pop-up, metal lever handle, durable metal construction, hybrid waterway, washerless cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. 3-hole 4" centerset sink application, washerless stem cartridge, plastic pop-up drain included. ADA compliant. low Rate: 1.5 gpm @ 60 psi, 5.7 L/min @ 414 kPa. Spout Length: 4 17/32".
WORK LGHT LED 5000L           Romex SIMpull 12/3UF-WGX100 Type UF-B Building Wire FAUCET LAV 2HNDL 4IN BANBURY
WORK LGHT LED 5000L
Our Price: $78.20
LED work light. Stays cool to the touch. 5x more energy efficient than Halogen lights. Sealed die-cast aluminum housing. Power cord with grounded plug. Long lasting super bright LEDs never need replacing. Adjustable tilt: 30 degrees down and 90 degrees up. Metal carrying handle. Sealed on/off switch. Indoor/outdoor approved. Impact resistant glass lens. 120V, 60 Hz, 5000K bright white. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Rotating spout, two-handle lever handles make it easy to adjust the water, 4" centerset design allows for easy installation, complies with Americans with Disabilities Act (ADA) specifications, aerated flow is ideal for everyday bathroom tasks, like brushing teeth and washing hands, meets EPA WaterSense criteria to conserve water without sacrificing performance, limited lifetime warranty, meets current legislation, including ab1953 (California) and s152 (Vermont). 1.2 gpm.
Romex SIMpull 10/3UF-WGX50 Type UF-B Building Wire Delta Windemere Traditional Lavatory Faucet Romex SIMpull 10/2UF-WGX50 Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. For exposed mounting on 3-hole sinks with 4" centers. Quarter-turn handle stops. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
FAUCET LAV 2HANDLE 4IN BANBURY FAUCET LAV 2HNDL BN LOW ARC   Delta 2522LF Classic Lavatory Faucet
Rotating spout, two-handle lever handles make it easy to adjust the water, 4" centerset design allows for easy installation, complies with Americans with Disabilities Act (ADA) specifications, aerated flow is ideal for everyday bathroom tasks, like brushing teeth and washing hands, meets EPA WaterSense criteria to conserve water without sacrificing performance, limited lifetime warranty, meets current legislation, including ab1953 (California) and s152 (Vermont). 1.2 gpm. Spot resistant brushed nickel finish resists fingerprints and water spots for a cleaner looking bath, two-handle lever handles make it easy to adjust the water, 4" centerset design allows for easy installation, complies with Americans with Disabilities Act (ADA) specifications, aerated flow is ideal for everyday bathroom tasks, like brushing teeth and washing hands, meets EPA WaterSense criteria to conserve water without sacrificing performance, limited lifetime warranty, meets current legislation, including ab1953 (California) and s152 (Vermont), , , Lav 2-H 4" Centerset with pop-up drain. 1.2 gpm. Two handle lavatory deck faucet for exposed mounting on three hole sinks. Solid brass fabricated body. 3-7/16" long spout. Control mechanism is of rotating cylinder type with stainless steel plate and 180 degree rotation, with replaceable non-metallic seats operating in stainless steel lined sockets. 1/2"-14 NPSM threaded male inlet shanks. Snap-N-Pop-Up drain with polypropylene pop-up type fitting with plated flange and stopper. Complies with ASME A112.18.1M-1996, CSA B125-93, IAPMO listed, and CSA certified.
American Standard Brands Winthrop Pop Up Lavatory Faucet LIGHT LED WORK 2500L W/USB-TRI Armolite 68583423 Solid Metal Clad Cable
Centerset on 4" centers. 1/4 turn washerless ceramic disc valve cartridges. Durable cast brass waterways with 1/2" male inlet shanks. Metal body. Color matched underbody, metal lever handles, 20" flexible stainless steel drain cable pre-assembled to faucet body, non-metallic speed connect drain body with 1-1/4" tail piece. 1.5 gpm. Lifetime Warranty. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
FAUCET 2 HANDLE CHROME GIBSON FAUCET LAV 4IN WIDE 2HNDL CHRM Coleman 160 Clamp Light
Chrome finish is highly reflective for a mirror-like look that works with any decorating style, two-handle lever handles make it easy to adjust the water, 4" centerset design allows for easy installation, complies with Americans with Disabilities Act (ADA) specifications, aerated flow is ideal for everyday bathroom tasks, like brushing teeth and washing hands, meets EPA WaterSense criteria to conserve water without sacrificing performance, limited lifetime warranty, meets current legislation, including ab1953 (California) and s152 (Vermont). 1.5 gpm. With plastic pop-up, metal lever handle, durable metal construction, hybrid waterway, washerless cartridge, 1/2" 14NPSM inlet, fits three hole 4" - 6" spread, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. For use in the home or shop. Made with tough, heat resistant sockets and vented aluminum reflectors, push-through switches, and strong double swivel clamps with vinyl grips. 5-1/2" reflection diameter. 60 watt/125 volt. UL Listed.
Coleman 946016618 Speaker Wire LIGHT STRING LED 5000L 50FT   Southwire UO7500050M Liquid Tight Flexible Conduit
Parallel wire, power limited circuit cable, -20 Celsius to 105 Celsius. Used for stereos and hi-fi systems, home theater sound systems, lamps, and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL Type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. LED String Lights. Five (5) high intensity LED light heads (1000 lumens each). Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
FAUCET LAV 4IN 2HNDL LEVER BRZ Romex SIMpull 10/2UF-WGX100 Type UF-B Building Wire Delta Leland Lavatory Faucet
With plastic pop-up, metal lever handle, durable metal construction, hybrid waterway, ceramic cartridge, 1/2" 14NPSM inlet, 4" centers, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Two handle lavatory deck faucet for exposed mounting on three hole sink. Solid brass fabricated body. 5-1/16" long, 4-1/8" high rigid spout and 1/4 turn stops. 1/2"-14 NPSM threaded male inlet shanks. Control mechanism is rotating cylinder type with stainless steel plate and 90 degree rotation, with replaceable non-metallic seats operating in stainless steel lined sockets. Complies with ASME A112.18.1, CSA B125.1, ASME A112.18.2, CSA B125.2, Compliance to ICC/ANSI A117.1. EPA Water Sense.
Coleman 167 Brooder Lamp FAUCET LAV 2 HANDLE CHROME    FAUCET LAV 4IN WIDE 2HNDL NICL
Features insulated porcelain sockets, heavy gauge aluminum reflectors and hang-up hooks. Bulb guards snap on the reflector, two-conductor and polarized male plugs. Sturdy clamp with vinyl coated grips hold lamp in place. Used for pig and chicken brooders or as a temporary heat source. 10" reflector diameter. 250 watts/125 volt. UL, cUL Listed. Two-handle lever handles make it easy to adjust the water, 4" centerset design allows for easy installation, complies with Americans with Disabilities Act (ADA) specifications, aerated flow is ideal for everyday bathroom tasks, like brushing teeth and washing hands, meets EPA WaterSense criteria to conserve water without sacrificing performance, limited lifetime warranty, meets current legislation, including ab1953 (California) and s152 (Vermont). 1.2 gpm. With plastic pop-up, metal lever handle, durable metal construction, hybrid waterway, washerless cartridge, 1/2" 14NPSM inlet, fits three hole 4" - 6" spread, IAMPO and NSF certified, max 1.2 Gpm at 60 psi.
WORKLIGHT DUALHD LED40W 4000LM FAUCET LAV CALDWELL BRONZE    WORK LGT W/TRIPD LED 2HD 6000L
FAUCET LAV CALDWELL BRONZE
Our Price: $105.16
High output dual head 2 x 20 watt LED work light provides a true 4,000 lumen output. Tripod extends total light height to 54" tall and has a quick-release system to remove lights from tripod for versatility. Sealed die-cast aluminum housing with impact resistant glass lenses. Long lasting LED bulbs with 5000K "Bright White" color temperature. Adjustable tilt from 30 degrees down to 90 degrees up. Indoor or outdoor use. Mediterranean bronze finish is highly reflective for a mirror-like look that works with any decorating style, two-handle lever handles make it easy to adjust the water, 4" centerset design allows for easy installation, complies with Americans with Disabilities Act (ADA) specifications, aerated flow is ideal for everyday bathroom tasks, like brushing teeth and washing hands, meets EPA WaterSense criteria to conserve water without sacrificing performance, limited lifetime warranty, meets current legislation, including ab1953 (California) and s152 (Vermont). 1.5 gpm. Sealed die-cast aluminum housing. 9? power cord with grounded plug. Long lasting super bright LEDs never need replacing. Adjustable tilt: 30 degrees down and 90 degrees up. Metal carrying handle. Sealed on/off switch on each light. Impact resistant glass lens. Metal base with rubber feet. Quick-release system for detaching lights from tripod. 120V, 60 Hz, 5000K bright white.
LIGHT LED WORK 4000L W/USB-TRI Duraclad 55278301 Type MC Armored Cable Delta Windemere Lavatory Faucet
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. For exposed mounting on 3-hole sinks with 4" centers. Quarter-turn handle stops.
Duraclad 55274901 Type MC Armored Cable Armorlite 68580001 Type MC Armored Cable Romex SIMpull 14/3UF-WGX250 Type UF-B Building Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Allied 103119 Rigid Conduit Coleman 151 Clamp Light Romex SIMpull 12/2UF-W/GX250 Building Wire
High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1. For use in the home or shop. Made with tough, heat resistant sockets and aluminum reflectors, push-through switches, and strong double swivel clamps with vinyl grips. 8-1/2" reflection diameter and 18/2 gauge conductor. 150 watts/125 volt. UL listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 10/3UF-W/GX100 Type UF-B Building Wire FAUCET LAV 4IN WIDE 2HNDL BRNZ Coleman 600006621 SPT-1 Lamp Cord
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. With plastic pop-up, metal lever handle, durable metal construction, hybrid waterway, washerless cartridge, 1/2" 14NPSM inlet, fits three hole 4" - 6" spread, IAMPO and NSF certified, max 1.2 Gpm at 60 psi. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 600006619 SPT-1 Lamp Cord Coleman 600006607 SPT-1 Lamp Cord Coleman 600006608 SPT-1 Lamp Cord