Home > PLUMBING > KITCHEN & BATH > FAUCETS > KITCHEN FAUCETS - SINGLE HANDL
Sort By:
1
Powerzone OR660606 SPT-2 Extension Cord Powerzone OR670606 SPT-2 Extension Cord Powerzone OR780609 SPT-2 Extension Cord
Three polarized outlets in a solid molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt/1625 watts. UL, cULus Listed for indoor use only. Three polarized outlets in a solid molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt/1625 watts. UL, cULus Listed for indoor use only. Household cord, indoor only. 16/2 SPT-2. One outlet to three.
Powerzone OR670609 SPT-2 Extension Cord Powerzone OR660609 SPT-2 Extension Cord Allied 101543 EMT Electrical Conduit
Three polarized outlets in a solid molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt/1625 watts. UL, cULus Listed for indoor use only. Three polarized outlets in a solid molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt/1625 watts. UL, cULus Listed for indoor use only. High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3.
Coleman 2235 SPT-2 Extension Cord Powerzone OR670612 SPT-2 Extension Cord Powerzone OR660612 SPT-2 Extension Cord
Indoor only, household cord. Thin male plug keeps cord close to wall. Plug does not block other outlets. 13 amp/125 volt. UL Listed. Sleeved. Three polarized outlets in a solid molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt/1625 watts. UL, cULus Listed for indoor use only. Three polarized outlets in a solid molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt/1625 watts. UL, cULus Listed for indoor use only.
Powerzone OR670615 SPT-2 Extension Cord Powerzone OR780615 SPT-2 Extension Cord Powerzone OR660615 SPT-2 Extension Cord
Three polarized outlets in a solid molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt/1625 watts. UL, cULus Listed for indoor use only. Three polarized outlets in a solid molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt/1625 watts. UL, cULus Listed for indoor use only. Three polarized outlets in a solid molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt/1625 watts. UL, cULus Listed for indoor use only.
Coleman 0814 SPT-2 3-Outlet Power Tap Extension Cord Powerzone OR920607 SPT-2 Extension Cord Coleman 2236 SPT-2 Extension Cord
Solid molded power taps, the convenience of 3 outlets in a compact design. Sleeved. Ultra thin 1/2" thick plug converts one outlet into three. Includes safety covers for unused outlets. UL, cULus Listed for indoor use only. Indoor only, household cord. Thin male plug keeps cord close to wall. Plug does not block other outlets. 13 amp/125 volt. UL Listed. Sleeved.
Coleman 2239 SPT-2 Extension Cord Coleman 2237 SPT-2 Extension Cord Thomas & Betts E989NNJ-CAR Rigid Junction Box
Indoor only, household cord. Thin male plug keeps cord close to wall. Plug does not block other outlets. 13 amp/125 volt. UL Listed. Sleeved. Indoor only, household cord. Thin male plug keeps cord close to wall. Plug does not block other outlets. 13 amp/125 volt. UL Listed. Sleeved. Manufactured from PVC  thermoplastic molding compound and featuring gasketed lids attached with stainless steel screws. Offers corrosion resistance and physical properties needed for direct burial applications. Intended for indoor or outdoor use, to provide a degree of protection against contact with enclosed equipment, falling dirt, hose directed water, entry of water during prolonged submersion at a limited depth, and external ice formation. UL Listed with a NEMA 6P rating per section 314.29.
Allied 101550 EMT Electrical Conduit Coleman 2241 SPT-2 Extension Cord Coleman 608 SPT-2 Cube Tap Extension Cord
High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3. Indoor only, household cord. Thin male plug keeps cord close to wall. Plug does not block other outlets. White, 13 amp/125 volt. UL Listed. Sleeved. Three polarized outlets in a molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt. UL Listed.
Coleman 609 SPT-2 Cube Tap Extension Cord Powerzone OR930606 SPT-2 Extension Cord CORD EXTEN FOOT SWITCH WHT 9FT
Three polarized outlets in a molded plug for convenient use indoors. Includes an attached safety cover for unused outlets. 13 amp/125 volt. UL Listed. Ultra thin 1/2" thick plug converts one outlet into three. Includes safety covers for unused outlets. UL, cULus Listed for indoor use only. Holiday 9' 3-outlet cord with footswitch.
Coleman 0864 SJTW 3-Outlet Power Tap Extension Cord CORD EXTEN FLAT PLUG 10FT WHT Mintcraft OR932610 Extension Cords
Solid molded power taps, the convenience of 3 outlets in a compact design. Sleeved. Ultra thin 1/2" thick plug converts one outlet into three. Includes safety covers for unused outlets. UL, cULus Listed for indoor use only.
Southwire 55082415 Armored Cable Powerzone OR932606 Flat Extension Cord Mintcraft OR890609 Office Cord
Wire whip, 14/3 AWG. Powerzone Extension Cord, Flat, 6 ft Conductor, 3, Black Jacket, 1/2 in Thick, 3-Prong, For Use with Indoor Household Fixtures Medium duty, 16/3 SJT.
CORD FAB BLACK 16/2 SPT-2 9FT CORD FAB GREY 16/2 SPT-2 9FT  Coleman 2865 SJT 3-Outlet Power Tap Extension Cord
Solid molded power taps, the convenience of 3 outlets in a compact design. Sleeved.
Allied 101568 EMT Conduit Coleman 2864 SJTW 3-Outlet Power Tap Extension Cord EXTENSION CORD SAFETY WHT 6FT
High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3. Solid molded power taps, the convenience of 3 outlets in a compact design. Sleeved. Safety cord monitors and senses excessive heat in outlets and plugs. When excessive heat is detected an audible alarm is sounded and a warning light is illuminated alerting about a possible issue before it becomes dangerous. Self-test button is on each end of the cord to test alerts. Safety shutters stop access to unused outlets.
EXTENSION CORD SAFETY GRN 6FT Carlon E987NR Rigid Junction Box Carlon E987RR Rigid Junction Box
Safety cord monitors and senses excessive heat in outlets and plugs. When excessive heat is detected an audible alarm is sounded and a warning light is illuminated alerting about a possible issue before it becomes dangerous. Self-test button is on each end of the cord to test alerts. Safety shutters stop access to unused outlets. Manufactured from PVC  thermoplastic molding compound and featuring gasketed lids attached with stainless steel screws. Offers corrosion resistance and physical properties needed for direct burial applications. Intended for indoor or outdoor use, to provide a degree of protection against contact with enclosed equipment, falling dirt, hose directed water, entry of water during prolonged submersion at a limited depth, and external ice formation. UL Listed with a NEMA 6P rating per section 314.29. Manufactured from PVC  thermoplastic molding compound and featuring gasketed lids attached with stainless steel screws. Offers corrosion resistance and physical properties needed for direct burial applications. Intended for indoor or outdoor use, to provide a degree of protection against contact with enclosed equipment, falling dirt, hose directed water, entry of water during prolonged submersion at a limited depth, and external ice formation. UL Listed with a NEMA 6P rating per section 314.29.
Coleman 872 SJTW 3-Outlet Power Tap Extension Cord Romex SIMpull 14/2NM-WGX25 Building Wire Coleman 0359W SPT-2 Extension Cord
Solid molded power taps, the convenience of 3 outlets in a compact design. Sleeved. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Manufactured with a polarized outlet in a molded plug for convenient use indoors. Remote on/off switch for easy power control. 13 amp/125 volt. Sleeved.
Romex SIMpull 14/2UF-W/GX25 Building Wire EXTENSION CORD SAFETY WHT 12FT Mintcraft OR890715 Shop Cords
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Safety cord monitors and senses excessive heat in outlets and plugs. When excessive heat is detected an audible alarm is sounded and a warning light is illuminated alerting about a possible issue before it becomes dangerous. Self-test button is on each end of the cord to test alerts. Safety shutters stop access to unused outlets. Heavy duty, 14/3.
Raco Wiegmann SC060604RC Pull Box Enclosure Armorlite 68580021 Type MC Armored Cable Armorlite 68579221 Type MC Armored Cable
Made of 16 gauge steel. Junction boxes for terminating power or communication conductors. Boxes have flat, removal covers fastened with screws. Mounting holes in the back. Gray enamel finish. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
CORD 2OTLT/2USB BLACK&WHT 6FT CORD 2OTLT/2USB PLTNM&WHT 6FT Romex SIMpull 12/2NM-WGX25 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Allied 101576 EMT Conduit Romex SIMpull 14/3NM-WGX25 Building Wire Duraclad 55278321 Type MC Armored Cable
High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Duraclad 55274921 Type MC Armored Cable Romex SIMpull 12/2UF-W/GX25 Building Wire Raco Wiegmann SC080804RC Pull Box Enclosure
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Made of 16 gauge steel. Junction boxes for terminating power or communication conductors. Boxes have flat, removal covers fastened with screws. Mounting holes in the back. Gray enamel finish.
Carlon E971FB-CAR Floor Base Box Allied 101584 EMT Conduit Romex SIMpull 14/2NM-WGX50 Building Wire
Non-metallic PVC floor box. Water tight gasket and corrosion resistant hardware. Concrete or wood subfloor construction approved. Minimum concrete dept required is 3-1/2". Will provide optional low voltage divider permitting three services (data, telephone, and power) access. Accepts 1/2", 3/4" and 1" conduit and has PVC molded ports. Includes two 1" x 3/4", two 3/4" x 1/2" reducer plugs and two 1" and 3/4" hubs. 90 cubic inch capacity. High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Alflex FO5000025M Type RWA Reduced Wall Flexible Conduit Alflex FO7500025M Type RWA Reduced Wall Flexible Conduit Allied 101592 EMT Conduit
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3.
Toolbasix PF8101A Kitchen Faucet Alflex FO3750050M Type RWA Reduced Wall Flexible Conduit Romex SIMpull 14/2UF-WGX50 Building Wire
8" centers. Single ABS lever handle, ABS construction, plastic waterways, washerless cartridge, 1/2" 14NPSM inlet, IAMPO & NSF certified. Carded. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Armorlite 68579222 Type MC Armored Cable Armorlite 68583421 Type MC Armored Cable Thomas & Betts B121BFBRR Adjustable Floor Box
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Duplex outlet with ABS cover and dual hinge caps to keep out dust. Adjusts from 0" to 1-7/8", 21 cubic inch capacity. UL Listed 5274 and classified 2HR W/C. UL514C scrub water tested. Patented residential design.
Duraclad 55274922 Type MC Armored Cable Duraclad 55278521 Type MC Armored Cable Southwire UO5000025M Liquid Tight Flexible Conduit
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
Duraclad 55275021 Type MC Armored Cable Romex SIMpull 10/2NM-WGX25 Building Wire Armolite 68580022 Solid Metal Clad Cable
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Toolbasix PF8111A Kitchen Faucet Romex SIMpull 12/3NM-WGX25 Building Wire Romex SIMpull 14/2NM-WGX100 Building Wire
8" centers. Single ABS lever handle, ABS construction, plastic waterways, washerless cartridge, 1/2" 14NPSM inlet, IAMPO & NSF certified. Carded. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Mintcraft RS207 Type O Bath Faucet 2 Handle Romex SIMpull 12/2NM-WGX50 Building Wire Romex SIMpull 14/3NM-WGX50 Building Wire
3-3/8" centers, Old-style bath faucet with dual metal lever handles, solid brass construction, solid brass waterways  less couplings. 23/32" IPS inlets. Boxed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Duraclad 55278322 Type MC Armored Cable Romex SIMpull 10/2UF-W/GX25 Type UF-B Building Wire Romex SIMpull 12/2UF-WGX50 Building Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
FAUCET KITCHEN 8IN LEVER CHRM Alflex FO5000050M Type RWA Reduced Wall Flexible Conduit Romex SIMpull 14/3UF-WGX50 Type UF-B Building Wire
Chrome, metal lever handle, durable metal construction, hybrid waterway, stainless steel ball valve, 1/2" 14NPSM inlet, 8" centers, IAMPO and NSF certified, max 1.8 Gpm at 60 psi. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 14/2UF-WGX100 Building Wire Carlon E971FBDI-2 Electrical Box Carlon E989R Rigid Junction Box
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Single hole installation. Includes everything needed to install including a hole saw, solid brass cover and single gang grounded receptacle. Low voltage telephone/cable insert plate included. Includes blank plate for custom installation. Polycarbonate construction. Manufactured from PVC  thermoplastic molding compound and featuring gasketed lids attached with stainless steel screws. Offers corrosion resistance and physical properties needed for direct burial applications. Intended for indoor or outdoor use, to provide a degree of protection against contact with enclosed equipment, falling dirt, hose directed water, entry of water during prolonged submersion at a limited depth, and external ice formation. UL Listed with a NEMA 6P rating per section 314.29.
Alflex FO37501001 Type RWA Reduced Wall Flexible Conduit Cooper TR5797 Tamper Resistant Floor Box Receptacle Alflex FO7500050M Type RWA Reduced Wall Flexible Conduit
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Includes box, gasket, receptacle, brass cover plate and closure cap with rubber "O" ring. Can be used in industrial and residential environments. UL Listed. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
FAUCET KITCHEN 8IN LEVER CHRM Romex SIMpull 14/2NM-WGX250 Building Wire Armolite 68583422 Solid Metal Clad Cable
Chrome, metal lever handle, durable metal construction, hybrid waterway, stainless steel ball valve, 1/2" 14NPSM inlet, 8" centers, IAMPO and NSF certified, max 1.8 Gpm at 60 psi. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Romex SIMpull 10/3NM-WGX25 Building Wire FAUCET KITCHEN 8IN LEVER CHRM Romex SIMpull 12/2NM-WGX100 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. With white hose spray on deck, chrome, metal lever handle, durable metal construction, hybrid waterway, stainless steel ball valve, 1/2in 14NPSM inlet, 8in centers, IAMPO and NSF certified, max 1.8 Gpm at 60 psi. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Mintcraft GU-TQOB015CP Tub Faucets Southwire UO7500025M Liquid Tight Flexible Conduit Armolite 68580023 Solid Metal Clad Cable
Tub faucet only, chrome, acrylic round handle, durable metal construction, solid brass waterway, washerless cartridge, zinc tub spout, IAMPO certified, max 2.0 Gpm at 80 psi. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
WIRE BUILDING 8/3NM-B W/G 25FT Alflex FO75001001 Type RWA Reduced Wall Flexible Conduit Duraclad 55278323 Type MC Armored Cable
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Duraclad 55274923 Type MC Armored Cable Carlon E97BRR Electrical Box Kit Romex SIMpull 12/3NM-WGX50 Building Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Flush floor mount, for duplex or GFCI receptacle, used with Carlon floor box  E971FB. Solid brass cover, plastic adapter ring, gasket and everything needed for installation is included. (Receptacle sold separately). Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/2UF-WGX100 Building Wire Southwire UO5000050M Liquid Tight Flexible Conduit Romex SIMpull 12/3UF-WGX50 Type UF-B Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Alflex FO50001001 Type RWA Reduced Wall Flexible Conduit Romex SIMpull 14/3NM-WGX100 Building Wire Raco 6224 Electrical Box
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Round duplex receptacle floor box. Duplex cover with lift lids, 2-1/2" bottom knockout, 18.5 cubic inch capacity. Cast iron construction with gray powder coat finish for corrosion resistance. Suitable for carpet, tile or wood floor applications. Mop water tight. If floor covering is used, discard included brass tile flange and replace with RACO 6235 carpet flange. Includes: box, brass duplex lift lid cover, and brass tile flange. Receptacle not included. UL Listed. 4.19" diameter.
Romex SIMpull 10/2NM-WGX50 Building Wire Moen Adler Kitchen Faucet Mintcraft 67534-1001 Kitchen Faucets
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. 4" center. 12550 ceramic disc cartridge design. Water/energy saving aerator. Hook-up supplies included. 1/2" IPS inlets. Inlet shanks will accept 3/8" ball nose connections. Third party certified to ASME A112.18.1/CSA B125.1, ICC A117.1 and all applicable requirements referenced therein, certified to ANSI/NSF 61/9. Complies with California Proposition 65 and with the Federal Safe Water Drinking Act. 1.5 gpm. With matching finish side spray, metal lever handle, durable metal construction, hybrid waterway, ceramic cartridge, 1/2" 14NPSM inlet, 8" centers, IAMPO and NSF certified, max 1.8 Gpm at 60 psi.
Romex SIMpull 12/2NM-WGX250 Building Wire Peerless P188500LF Kitchen Faucet Peerless P188200LF Kitchen Faucet
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. 4-hole, 8" sink application,washerless ball valve, spout swivels 360 degrees for added convenience, ADA Compliant. Spout length: 9", Flow Rate: 1.8 gpm @ 60 psi, 6.8 L/min @414 kPa 3-hole sink application, washerless ball valve, spout swivels 360 degrees for added convenience, ADA Compliant, 9" spout length.
Romex SIMpull 14/2UF-W/GX250 Building Wire WIRE BUILDING 6/3NM-B W/G 25FT Moen Adler Kitchen Faucet
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Chrome finish, Duralock quick connect system, complies with ADA specifications. 3-hole, 3/8" compression connection, 1255 Duralast cartridge. 1.5 gpm.
Romex SIMpull 14/3NM-WGX250 Building Wire Moen Adler Kitchen Faucet Peerless P188720 Tub/Shower Faucet
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. 4" center. 12550 ceramic disc cartridge design. Water/energy saving aerator. Hook-up supplies included. 1/2" IPS inlets. Inlet shanks will accept 3/8" ball nose connections. Third party certified to ASME A112.18.1/CSA B125.1, ICC A117.1 and all applicable requirements referenced therein, certified to ANSI/NSF 61/9. Complies with California Proposition 65 and with the Federal Safe Water Drinking Act. 1.5 gpm. Includes both metal lever and acrylic knob handles to match any decor. Pressure balance valve keeps water temperature within +/-3 degrees F. ADA Compliant. Flow Rate: 2.0 gpm @ 60 psi, 7.6 L/min @ 414 kPa.
Romex SIMpull 12/3UF-WGX100 Type UF-B Building Wire American Standard Jocelyn Kitchen Faucet Romex SIMpull 10/2UF-WGX50 Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Cast brass 8-1/2" swivel spout, washerless 40mm ceramic disc valve cartridge, cast brass waterway with 1/2" male inlet shanks, metal escutcheon plate (10-5/16"H x 2-3/8"W). 1.8 gpm. Lifetime Warranty. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 10/3UF-WGX50 Type UF-B Building Wire Delta 100-DST Kitchen Faucet Moen Adler Kitchen Faucet
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Three hole , 8" installation, 8" swing spout. 1/2" IPS inlets Lever-style handle. 1/2" IPS connections will accept standard ball nose connection for 3/8" tubing. 9" sprout reach, 4 hole application. Aerator is limited to 1.5 gpm max. 1255 cartridge design, nonmetallic, nonferrous and stainless steel materials. Complies with requirements of CSA B-125, ASME A112.18.1M, ANSI A117.1, and ADA. Certified to ANSI/NSF61/9. Compliant with California Proposition 65 and with the Federal Safe Water Drinking Act. 1/2" IPS connectors.
TUB/SHWR ST PRES/BAL PLSH CHM American Standard Jocelyn Tub and Shower Faucet Moen Banbury Kitchen Faucet
Cast brass body, washerless ceramic disc valve cartridge with back-to-back capability and hot limit safety stop. Cycles from off to hot through cold. Pressure balancing cartridge maintains constant output temperature in response to changes in relative hot and cold supply pressure. 1/2" female IPS inlets and outlets, easy clean showerhead with 2.5 gpm flow restrictor, rough-in plaster guard designed for use as thin-wall mounting adapter. Cast brass body, washerless ceramic disc valve cartridge with back-to-back capability and hot limit safety stop. Cycles from off to hot through cold. Pressure balancing cartridge maintains constant output temperature in response to changes in relative hot and cold supply pressure. 1/2" female IPS inlets and outlets, easy clean showerhead with 2.5 gpm flow restrictor, rough-in plaster guard designed for use as thin-wall mounting adapter. Lifetime Warranty. Low arc kitchen faucet with side spray, four hole application, one function sprayer, 1/2 IPS connection, 1255 ceramic cartridge, deckplate included Chrome finish. 1.5 gpm.
Delta Classic Kitchen Faucet Mintcraft 67534-1004 Kitchen Faucet Armolite 68583423 Solid Metal Clad Cable
8" installation. Diamond seal valve, 2.2gpm at 60psi, 8" long spout swings 360 degrees for added convenience, ADA compliant. With matching finish side spray, metal lever handle, durable metal construction, hybrid waterway, ceramic cartridge, 1/2" 14NPSM inlet, 8" centers, IAMPO and NSF certified, max 1.8 Gpm at 60 psi. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Romex SIMpull 10/3NM-WGX50 Building Wire Southwire UO7500050M Liquid Tight Flexible Conduit TUB/SHOWER SET PRES/BAL BN
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Cast brass body, washerless ceramic disc valve cartridge with back-to-back capability and hot limit safety stop. Cycles from off to hot through cold. Pressure balancing cartridge maintains constant output temperature in response to changes in relative hot and cold supply pressure. 1/2" female IPS inlets and outlets, easy clean showerhead with 2.5 gpm flow restrictor, rough-in plaster guard designed for use as thin-wall mounting adapter.
Romex SIMpull 10/2UF-WGX100 Type UF-B Building Wire Moen Adler Tub/Shower Faucet American Standard Winthrop Tub and Shower Faucet
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Chrome-plated metal lever handle, valve, showerhead, arm, flange, and tub spout. 1/2" IPS connections. Pressure balancing cycle valve design with an adjustable temperature limit stop, maintains selected discharge temperature to +/-2 degrees. Showerhead limited to 2.0 gpm (9.5 L/min). 1222 design cartridge, of nonmetallic/nonferrous and stainless steel materials. Accommodates back-to-back installations. Meets CSA, ASME/ANSI requirements.  ADA Compliant. Cast brass body, washerless ceramic disc valve cartridge with back-to-back capability and hot limit safety stop. Cycles from off to hot through cold. Pressure balancing cartridge maintains constant output temperature in response to changes in relative hot and cold supply pressure. 1/2" female IPS inlets and outlets, easy clean showerhead with 2.5 gpm flow restrictor, rough-in plaster guard designed for use as thin-wall mounting adapter. Lifetime Warranty.
Romex SIMpull 12/3NM-WGX100 Type NM-B Building Wire Delta Classic Kitchen Faucet Delta Monitor Tub/Shower Faucet
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. 8" installation. Diamond seal valve, 2.2gpm at 60psi, 8" long spout swings 360 degrees for added convenience, ADA compliant. Single lever handle pressure balance tub and shower faucet. Pressure balance valve ensures bathing water remains a consistent temperature through any change in water pressure and prevents scalding with an internal limit-stop that prevents water temperatures from rising to a dangerous level. Includes showerhead, arm, flange, and tub spout with diverter. Solid brass construction and brass waterways. ADA certified. Lifetime limited faucet and finish warranty. Chrome finish.
Moen Adler 82402 Tub and Shower Faucet Duraclad 55278301 Type MC Armored Cable Moen Lindley Kitchen Faucet
Chrome finish, lever design, 4" diameter spray head, 4-7/8 tub spout length, 1/2" IPS connection, 1224 cartridge, 2.0 gpm max., ADA compliant. Includes head, arm, flange and diverter tub spout. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Chrome finish, side spray, Hydrolock quick connect system, four hole installation, 1/2" IPS connection, 1.5 gpm max, ADA compliant.
Moen Lindley Kitchen Faucet Duraclad 55274901 Type MC Armored Cable WIRE BUILDING 8/3NM-B W/G 50FT
Low arc, chrome finish, Duralock quick connect system for easy installation, complies with American with Disabilities Act specifications. 1255 Duralast cartridge, flexible supply lines with 3/8" compression fittings.1.5 gpm. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C.
Moen Muirfield Kitchen Faucet Moen Adler Classic Tub and Shower Faucet Armorlite 68580001 Type MC Armored Cable
Low arc faucet with one-function side spray, 4-hole mounting, 1/2" IPS connection, 1255 ceramic cartridge, deckplate included. Classic Chrome finish. 1.5 gpm. Chrome finish, lever design, 4" diameter spray head, 4-7/8" tub spout length, 1/2" IPS connection, 1224 cartridge, 2.0 gpm max., ADA compliant. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Delta 440-DST Collins Kitchen Faucet Romex SIMpull 14/3UF-WGX250 Type UF-B Building Wire Peerless P188775 Tub/Shower Faucet
8" center, 9" swivel spout with single lever handle. Quick Snap vegetable sprayer hose with matching finish sprayhead. 45" long hose. Requires 4-hole installation. Supplied with universal fittings to accept 3/8" copper sweat, 3/8" compression, includes adapters to accept 1/2" iron pipe. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Pressure balance valve keeps water temperature within +/-3 degrees F. Includes MultiChoice Valve which allows for upgrade to Dual-Function shower trim and cartridge, ADA Compliant. Flow Rate: 2.0 gpm @ 60 psi, 7.6 L/min @ 414 kPa.
Romex SIMpull 10/2NM-WGX100 Type NM-B Building Wire Coleman 600006621 SPT-1 Lamp Cord Coleman 600006619 SPT-1 Lamp Cord
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 600006607 SPT-1 Lamp Cord Coleman 600006608 SPT-1 Lamp Cord Coleman 600006618 SPT-1 Lamp Cord
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 600006601 SPT-1 Lamp Cord Peerless P188775-BN Tub/Shower Faucet Romex SIMpull 10/3UF-W/GX100 Type UF-B Building Wire
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Pressure balance valve keeps water temperature within +/-3 degrees F. Includes MultiChoice Valve which allows for upgrade to Dual-Function shower trim and cartridge, ADA Compliant. Flow Rate: 2.0 gpm @ 60 psi, 7.6 L/min @ 414 kPa. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 12/2UF-W/GX250 Building Wire Moen Torrance Kitchen Faucet Southwire UO500001001 Liquid Tight Flexible Conduit
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Metal construction. Inlet shanks will accept 3/8" ball nose connections. Includes Protege side spray. Lever style handle. Pull-on/push-off. Operates with less than 5 lbs. of force. Aerator is limited to 1.5 gpm max. Third party certified to CSA B125, ASME A112.18.1M, ANSI A117.1 and all applicable requirements referenced therein. Certified to ANSI/NSF 61/9. Complies with California Proposition 65 and with the Federal Safe Water Drinking Act. ADA compliant. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
Romex SIMpull 8/2NM-WGX125 Type NM-B Building Wire Delta Faucet 144984 Tub/Shower Faucet Moen Chateau Kitchen Faucet
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Tub and shower trim. Single-function pressure balanced cartridge, 2.0 gpm at80 psi. Full body spray, massaging spray, soft drench spray. Solid brass forged body, AD compliant, WaterSense labeled. One solid lever handle. Energy saving flow-rator, aerator. Includes Protege side spray. ADA compliant.
Delta Faucet 144996 Tub/Shower Faucet Romex SIMpull 12/3NM-WGX250 Type NM-B Building Wire Romex SIMpull 28827472 Type NM-B Building Wire
Monitor14 Series pressure balanced bath mixing valve with Scald-Guard. Solid brass forged body, MultiChoice Universal rough valve body included. ADA compliant, WaterSense labeled. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Moen Banbury Tub and Shower Faucet Delta Monitor 1343 Tub/Shower Trim Delta Monitor Tub/Shower Faucet
Chrome finish, lever design, PosiTemp pressure-balancing valve maintains water pressure and controls temperature, 1/2" IPS connection, 2.0 gpm max. Pressure balanced single handle bath mixing valve. Requires 1-1/2" wall cavity. Back-to-back installation capability. Solid brass fabricated body. Monitor with Scald-Guard valve maintains a balanced pressure of hot and cold water even when a valve is turned on or off elsewhere in the system. Lever handle. Temperature only controlled with handle. Field adjustable to limit handle rotation into hot water zone. 120 degree maximum handle rotation. All parts are replaceable from the front of the valve. Easy-to-clean, Touch-Clean showerhead provides full-spray pattern. Pull-up diverter spout for easy shower operation. Complies with ASME A112.18.1M-1996, ASSE 1016-1996, CSA B125-93, Showerhead: GSA A-A-240, ASSE seal authorized, City of L.A. approved, CSA certified, and IAPMO listed. ADA compliant. Crystal-like handle. Supplied with a break-away tab in valve body, which allows stem to be reversed, allowing reverse piping application. Temperature only controlled with handle. 1/2" IPS inlets. Monitor Scald-Guard valve keeps water temperature within +/-3Degrees F.
Delta 340-DST Collins Kitchen Faucet Delta Faucet 4453-DST Kitchen Faucet American Standard 9046502.181 Tub/Shower Faucets
Single handle kitchen deck faucet for exposed mounting on three hole sinks. Solid brass fabricated body. 9-1/16" long spout swings 360 degrees. Lever handle returns to neutral position when faucet is turned off. Red and blue button on handle. Control mechanism is of rotating stainless steel ball type with replaceable non-metallic seats operating in stainless steel lined sockets. 3/8" O.D. straight, staggered copper supply tubes - 5-7/8" and 7-1/4" long supplied with 1/2"-14 NPSM adapters. Spray attachment has anti-siphon device as integral part of valve body. Includes Quick Snap vegetable sprayer hose with matching finish sprayhead. 45" long hose. Complies with ASME A112.18.1, CSA B125, IAPMO listed, CSA certified, and City of L.A. approved. ADA compliant. Tall arc spout, Diamond Seal valve, 2 or 4-hole 8" installation. 9-13/16" spout. 10-1/2" escutcheon included. Cast brass body, washerless ceramic disc valve cartridge with back-to-back capability and hot limit safety stop. Cycles from off to hot through cold. Pressure balancing cartridge maintains constant output temperature in response to changes in relative hot and cold supply pressure. 1/2" female IPS inlets and outlets, easy clean showerhead with 2.5 gpm flow restrictor, rough-in plaster guard designed for use as thin-wall mounting adapter. Lifetime Warranty.
Southwire UO75001001 Liquid Tight Flexible Conduit Romex SIMpull 10/3NM-WGX100 Type NM-B Building Wire FAUCET 1 HANDLE CHROME GIBSON
Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. 4-1/2" diameter spray ahead, 6-1/2 tub spout, chrome finish, lever handle, equipped with the PosiTemp pressure?balancing control valve to help maintain water temperature in the shower.
Coleman 601266607 SPT-2 Lamp Cord Coleman 601266608 SPT-2 Lamp Cord Coleman 601266601 SPT-2 Lamp Cord
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Romex SIMpull 10/2NM-WGX250 Type NM-B Building Wire Moen Wetherly Kitchen Faucet WIRE BUILDING 6/3NM-B W/G 50FT
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Side spray, conventional deck mounting, 2 or 4 hole application, 3/8" compression connection, 7.87" spout height, 1.5 gpm. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C.
Romex SIMpull 12/3UF-WGX250 Type UF-B Building Wire Delta Monitor Tub/Shower Trim Delta 440-SS-DST Collins Kitchen Faucet
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Monitor 14 series pressure balanced bath mixing valve, universal rough valve body included, maintains a balanced pressure of hot and cold water even when a valve is turned on or off elsewhere in the system. Solid brass forged body. 4-hole 8" centers, 9-3/16" spout swings 180 degrees, diamond coated ceramic cartridge, 3/8" compression gasket fittings.
Moen 82830EP Tub/Shower Faucet Moen Wetherly Kitchen Faucet Moen Banbury Tub/Shower Faucet
PosiTemp pressure-balancing control valve, 6" diameter spray head, 6" tub spout, complies with ADA specifications. 2.0 gpm. Side spray, conventional deck mounting, 2 or 4 hole application, 3/8" compression connection, 7.87" spout height, 1.5 gpm. One handle tub and shower faucet with Posi-Temp pressure balancing valve. Metal construction with 1/2" IPS connections. Boxed. 2.0 gpm.
Romex SIMpull 6/2NM-WGX125 Type NM-B Building Wire Romex SIMpull 8/3NM-WGX125 Type NM-B Building Wire Moen Caldwell PosiTemp 82496EPBRB Tub/Shower Faucet