Home > ELECTRICAL > SPECIALTY ELECTRICAL > TELEPHONE & ACCESSORIES > TELEPHONES & ANSWERING MACHIN
Sort By:
1
Arrow Hart 2131 Standard Wall Plate Arrow Hart 2131V-BOX Round Wall Plate Cooper 270B Grounded  Duplex Receptacle
Molded from non-flammable thermoset. Flush fitting, warp resistant design. Screw-catch feature holds mounting screws captive and simplifies installation. Matching screws provided. High gloss finish is soil resistant. Standard size - 2.75" x 4.50", boxed. Molded from non-flammable thermoset. Flush fitting, warp resistant design. Screw-catch feature holds mounting screws captive and simplifies installation. Matching screws provided. High gloss finish is soil resistant. Standard size - 2.75" x 4.50", boxed. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements.
Cooper 270V Grounded  Duplex Receptacle Cooper 270W Grounded  Duplex Receptacle RECEPTACLE DUPLEX 15A 125V LA
Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements.
WALLPLATE RCPT LT ALMOND 1G   Cooper TR270W  Tamper Resistant Duplex Receptacle Cooper TR270V  Tamper Resistant Duplex Receptacle
Virtually unbreakable, with high structural rigidity, long-term form retention and impact and abrasion resistance. Screw-catch feature holds mounting screws captive. Matching screws provided. High gloss finish is soil resistant. Mid-size - 3.125" x 4.875". Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed.
Cooper TR270V Tamper Resistant Duplex Receptacle Cooper TR270W Tamper Resistant Duplex Receptacle RECEPTACLE DUPLEX LIGHT ALMOND
Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed.
Arrow Hart CR15W  Duplex Receptacle Cooper 736B-BOX  Duplex Receptacle Cooper 736V-BOX  Duplex Receptacle
Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Standard contacts. Side wire terminals accept up to #12 wire. Terminal screws backed out, ready for wiring. 15 amp/125 volt. UL Listed. Standard contacts. Side wire terminals accept up to #12 wire. Terminal screws backed out, ready for wiring. 15 amp/125 volt. UL Listed.
Cooper 736W-BOX  Duplex Receptacle Arrow Hart CR15B  Duplex Receptacle Arrow Hart CR15V  Duplex Receptacle
Standard contacts. Side wire terminals accept up to #12 wire. Terminal screws backed out, ready for wiring. 15 amp/125 volt. UL Listed. Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed.
Cooper BP231B-SP Wall Plate Screw Cooper BP231W-SP Wall Plate Screw Cooper BP231V-SP Wall Plate Screw
Colors to match wall plates. 6/32" x 1/2". UL Listed. Colors to match wall plates. 6/32" x 1/2". UL Listed. Colors to match wall plates. 6/32" x 1/2". UL Listed.
Cooper 1107V Decorator  Duplex Receptacle Cooper 1107W Grounded  Duplex Receptacle RECEPTACLE DECOR 2P 3W 15A LA
Longer, wider strap provides 40 percent more contact area to wall board. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire and wire looper for pre-looping. Combination slot/Phillips head mounting and terminal screws for installation with power screwdrivers. Terminal screws backed out - ready for wiring. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no. E15058), Fed. Specs. WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. Longer, wider strap provides 40 percent more contact area to wall board. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire and wire looper for pre-looping. Combination slot/Phillips head mounting and terminal screws for installation with power screwdrivers. Terminal screws backed out - ready for wiring. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no. E15058), Fed. Specs. WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed.
RECEPTACLE BULK LT ALMOND 20A Arrow Hart CR20W Grounded Duplex Receptacle Arrow Hart CR20V Grounded Duplex Receptacle
Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed.
Arrow Hart CR20B Grounded Duplex Receptacle Spot-Gro C270V Duplex  Electrical Receptacle Cooper C270W  Duplex Receptacle
Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements.
RECEPTACLE DECO AG LT ALMOND  Cooper 1107-9BK Decorator  Duplex Receptacle Arrow Hart BR15V  Duplex Receptacle
Terminal screws backed out-ready for wiring. Push-in terminals accept number 14 solid wire. Side wire terminals accept up to number 10 solid or stranded wire. Longer, wider strap provides 40 percent more contact area to wall board. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire to speed installation. Built-in wire looper for pre-looping. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no.E15058), Fed.Specs.WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. Terminal screws backed out-ready for wiring. Push-in terminals accept number 14 solid wire. Side wire terminals accept up to number 10 solid or stranded wire. Longer, wider strap provides 40 percent more contact area to wall board. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire to speed installation. Built-in wire looper for pre-looping. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no.E15058), Fed.Specs.WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed.
Arrow Hart BR15W  Duplex Receptacle Arrow Hart 93111-BOX Standard Wall Plate Arrow Hart 93091-BOX Standard Wall Plate
High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed. Made of Type 304 stainless steel alloy for superior non-magnetic corrosion-resistant properties. Plates are 0.032" thick. Brushed satin finish resists fingerprints. Matching stainless steel mounting screws provided. Standard size - 2.75" x 4.50", with 1.594" hole. Made of Type 304 stainless steel alloy for superior non-magnetic corrosion-resistant properties. Plates are 0.032" thick. Brushed satin finish resists fingerprints. Matching stainless steel mounting screws provided. Standard size - 2.75" x 4.50", with 1.406" hole, boxed.
Cooper TR1107W Decorative Tamper Resistant Duplex Receptacle Cooper TR1107V Decorative Tamper Resistant Duplex Receptacle Cooper TR1107V Decorator Tamper Resistant Duplex Receptacle
Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed.
Cooper TR1107W Decorator Tamper Resistant Duplex Receptacle Arrow Hart BR20V  Duplex Receptacle Arrow Hart BR20W  Duplex Receptacle
Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed.
Arrow Hart BR20A  Duplex Receptacle Amerelle Century 1-Rocker 1-Toggle Wall Plate Arrow Hart 39CH-BOX Wall Plate
High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed. Amerelle Wall Plate, 1-Rocker, 1-Toggle, Series: Century, 4-15/16 in Length, 4-9/16 in Width, 2 Gangs, Stamped Steel, Brushed Nickel, Screw Mounting, Includes: Matching Screws, UL Listed Full gauge and size beveled-edge; furnished with mounting screws. Fit 1253, 1254 and 1263 flush receptacles. Standard size - 2.75" x 4.50", boxed.
Arrow Hart Eagle 69-BOX Standard Wall Plate RECEPTACLE COMM LT ALMOND 20A Cooper 5270  Standard Duplex Receptacle
Fits 1257 and 1258 flush receptacles. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed. Meets all UL 498 and 1567 requirements. Longer, wider strap provides 40 percent more contact area. Side wire terminals accept up to #10 solid or standard copper or aluminum wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. 15 amp, 125 volt. Bulk pack.
Cooper 5270  Standard Duplex Receptacle Arrow Hart Eagle 68-BOX Standard Wall Plate Cooper 827 Duplex Receptacle
Meets all UL 498 and 1567 requirements. Longer, wider strap provides 40 percent more contact area. Side wire terminals accept up to #10 solid or standard copper or aluminum wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. 15 amp, 125 volt. Bulk pack. Standard size two gang metal wallplate for power devices using a 2.1563" single opening. Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws.
Cooper 827 Duplex Receptacle Cooper 827 Duplex Receptacle Cooper TWR270W Tamper Resistant Weatherproof Duplex Receptacle
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws. Receptacle is residential grade, duplex, tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. TR and WR designations provide visual identification. UL, cULus listed. 15 amp, 125 volt.
Cooper TWR270V Tamper Resistant Weatherproof Duplex Receptacle Cooper 877 Grounded Duplex Receptacle Cooper 877 Grounded Duplex Receptacle
Receptacle is residential grade, duplex, tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. TR and WR designations provide visual identification. UL, cULus listed. 15 amp, 125 volt. Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws.
Cooper 877 Grounded Duplex Receptacle Cooper A12 869-BOX  Duplex Receptacle Aspire 9505 Duplex Recessed Tamper Resistant Electrical Receptacle
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws. Commercial specification grade straight blade receptacle on 4" galvanized steel cover. Back and side wire. 15 amp 125 volt. 5-15R NEMA. Temperature rating of -20 to 60 degrees C. UL Listed, meets all CSA requirements, NOM Certified. Receptacle is residential grade, duplex, tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. An oversized strap provides a solid base for mounting and virtually eliminates "floating" installations. Thermoplastic construction ultrasonically welded top and backbody; extra-long, extra-wide mounting straps; number 12 and number 14 push-in terminals; backwire clamps on side terminals; easy-access ground screws; built-in wire strippers. Meets all UL 498 requirements, (file no. E15058); CSA Certified, C22.2 no. 42 (file no. 6914 (6233-01); NOM Certified. Flammability rating: V2 per UL 94. temperature rating: -40 degrees C to 65 degrees C. TR designations provides visual identification. UL, cULus Listed. 15 amp, 125 volt.
Aspire 9505 Duplex Recessed Tamper Resistant Electrical Receptacle RECEPT DUPLEX RB 15A 125V 2P3W Arrow Hart Eagle 2168 Standard Wall Plate
Receptacle is residential grade, duplex, tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. An oversized strap provides a solid base for mounting and virtually eliminates "floating" installations. Thermoplastic construction ultrasonically welded top and backbody; extra-long, extra-wide mounting straps; number 12 and number 14 push-in terminals; backwire clamps on side terminals; easy-access ground screws; built-in wire strippers. Meets all UL 498 requirements, (file no. E15058); CSA Certified, C22.2 no. 42 (file no. 6914 (6233-01); NOM Certified. Flammability rating: V2 per UL 94. temperature rating: -40 degrees C to 65 degrees C. TR designations provides visual identification. UL, cULus Listed. 15 amp, 125 volt. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed. Screw-catch feature holds mounting screws captive and simplifies installation. Matching mounting screws provided.
Cooper C1507V Grounded Standard Duplex Receptacle Cooper C1507W Grounded Standard Duplex Receptacle Arrow Hart TR Duplex Receptacle
With No. 1107 wall plate. UL Listed. 15 amp, 125 volt, grounded. Carded. With No. 1107 wall plate. UL Listed. 15 amp, 125 volt, grounded. Carded. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal Specifications WC-596. UL Listed. Tamper resistant receptacles have a UL Listed shutter system.
Arrow Hart TR Duplex Receptacle Cooper 270V10 Grounded  Duplex Receptacle Cooper 270W Grounded  Duplex Receptacle
High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal Specifications WC-596. UL Listed. Tamper resistant receptacles have a UL Listed shutter system. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements.
Arrow Hart TRBR20W-BXSP Tamper Resistant Duplex Receptacle Arrow Hart TRBR20V-BXSP Tamper Resistant Duplex Receptacle Arrow Hart Arrow Link 5252  Duplex Receptacle
High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal Specifications WC-596. UL Listed. Tamper resistant receptacles have a UL Listed shutter system. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal Specifications WC-596. UL Listed. Tamper resistant receptacles have a UL Listed shutter system. High impact and chemical-resistant nylon face. Rigid glass reinforced nylon base. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Long, broad mounting strap. Meets all UL 498 requirements UL Listed. Screw-catch feature speeds mounting of wall plates. Combination slot/Phillips/Robertson terminal and mounting screws. 5-leaf solid brass line contacts for lowest heat rise, smooth plug blade insertion and long term retention.
AmerTac Zenith VT1006COMPOS Composite Audio Video Cable Cooper TWRBR15V Tamper Resistant Weatherproof Duplex Receptacle Cooper TWRBR15W-BXSP Tamper Resistant Weatherproof Duplex Receptacle
Reliable audio/video connection between components. Color coded connectors. Tamper and weather resistant commercial grade duplex receptacle with a UL Listed shutter system, back and side wiring. -4 to 158 degrees F temperature rating. Withstands 2000 volts per UL498. Body is thermoplastic nylon, the strap and terminal clamps are nickel plated steel. The contacts are a brass alloy. UL Listed to UL498, UL Certified to CSA C22.2, no. 42, UL verified to Fed. Spec. WC-596G, and NOM/ANSI Certified. Meets UL 94 flammability requirements; V2 rated. TR and WR designations provide visual identification. UL, cULus Listed. Tamper and weather resistant commercial grade duplex receptacle with a UL Listed shutter system, back and side wiring. -4 to 158 degrees F temperature rating. Withstands 2000 volts per UL498. Body is thermoplastic nylon, the strap and terminal clamps are nickel plated steel. The contacts are a brass alloy. UL Listed to UL498, UL Certified to CSA C22.2, no. 42, UL verified to Fed. Spec. WC-596G, and NOM/ANSI Certified. Meets UL 94 flammability requirements; V2 rated. TR and WR designations provide visual identification. UL, cULus Listed.
AmerTac 935TDW Wall Plate AmerTac Zenith VV1006SVID Type S Video Cable Cooper 542B-BOX Duplex Receptacle
With screws. 5" height x 4-5/8" width x 1/4" depth. S-video black cable. Transfers video signals between components. For use with satellite receivers, cable boxes, DVD players, and video recorders. NEMA 5-15R. For pole barns. 15 amp, 125 volt.
AmerTac CD1001LASCLR Lens Cleaner Cooper TWRBR20V Tamper Resistant Weatherproof Duplex Receptacle Cooper TWRBR20W-BXSP Tamper Resistant Weatherproof Duplex Receptacle
Keeps DVD optical laser lens clean and dust free. Programmed with voice and music guide in 11 languages. Tamper and weather resistant commercial grade duplex receptacle with a UL Listed shutter system, back and side wiring. -4 to 158 degrees F temperature rating. Withstands 2000 volts per UL498. Body is thermoplastic nylon, the strap and terminal clamps are nickel plated steel. The contacts are a brass alloy. UL Listed to UL498, UL Certified to CSA C22.2, no. 42, UL verified to Fed. Spec. WC-596G, and NOM/ANSI Certified. Meets UL 94 flammability requirements; V2 rated. TR and WR designations provide visual identification. UL, cULus Listed. Tamper and weather resistant commercial grade duplex receptacle with a UL Listed shutter system, back and side wiring. -4 to 158 degrees F temperature rating. Withstands 2000 volts per UL498. Body is thermoplastic nylon, the strap and terminal clamps are nickel plated steel. The contacts are a brass alloy. UL Listed to UL498, UL Certified to CSA C22.2, no. 42, UL verified to Fed. Spec. WC-596G, and NOM/ANSI Certified. Meets UL 94 flammability requirements; V2 rated. TR and WR designations provide visual identification. UL, cULus Listed.
Arrow Hart Arrow Link 5352  Duplex Receptacle AmerTac Zenith VC1006COMPON Component Video Cable Arrow Hart 2131W-BOX Round Wall Plate
High impact and chemical-resistant nylon face. Rigid glass reinforced nylon base. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Long, broad mounting strap. Meets all UL 498 requirements UL Listed. Screw-catch feature speeds mounting of wall plates. Combination slot/Phillips/Robertson terminal and mounting screws. 5-leaf solid brass line contacts for lowest heat rise, smooth plug blade insertion and long term retention. Color coded connectors, black cable. Transfers video signals between components. Molded from non-flammable thermoset. Flush fitting, warp resistant design. Screw-catch feature holds mounting screws captive and simplifies installation. Matching screws provided. High gloss finish is soil resistant. Standard size - 2.75" x 4.50", boxed.
AmerTac VN1001MKITWL V Antenna Wall Mounting Kit Arrow Hart AH8300W  Duplex Receptacle Arrow Hart AH8300RD  Duplex Receptacle
Galvanized steel. For mounting antenna to side of building. Includes: (2) brackets, (2) u-bolts, all needed hardware. Heavy gauge brass line contacts. High impact and chemical-resistant nylon face. Automatic grounding system. Terminal sizes number 14 - 10 AWG. Voltage ratings permanently marked on device. Materials face and base are nylon, strap is 0.05" thick steel, zinc plated, auto ground clip is bronze wire. Line contacts are 0.037" triple-wipe brass, terminal screws  are number 8-32 steel, ground screw is  number 8-32 steel (green). Screw terminal guards are PVC. Listed to UL 498, UL verified to Federal Spec. WC-596G, CSA Certified to C22.2, no. 42. Flammability meets UL 94 requirements; V2.temperature rating: -4 to 158 degrees F. Dielectric voltage: withstands 2000 volts per UL 498. Heavy gauge brass line contacts. High impact and chemical-resistant nylon face. Automatic grounding system. Terminal sizes number 14 - 10 AWG. Voltage ratings permanently marked on device. Materials face and base are nylon, strap is 0.05" thick steel, zinc plated, auto ground clip is bronze wire. Line contacts are 0.037" triple-wipe brass, terminal screws  are number 8-32 steel, ground screw is  number 8-32 steel (green). Screw terminal guards are PVC. Listed to UL 498, UL verified to Federal Spec. WC-596G, CSA Certified to C22.2, no. 42. Flammability meets UL 94 requirements; V2.temperature rating: -4 to 158 degrees F. Dielectric voltage: withstands 2000 volts per UL 498.
Arrow Hart AH8300V  Duplex Receptacle AmerTac Zenith VC1012COMPON Component Video Cable Arrow Hart 5131B-BOX Wall Plate
Heavy gauge brass line contacts. High impact and chemical-resistant nylon face. Automatic grounding system. Terminal sizes number 14 - 10 AWG. Voltage ratings permanently marked on device. Materials face and base are nylon, strap is 0.05" thick steel, zinc plated, auto ground clip is bronze wire. Line contacts are 0.037" triple-wipe brass, terminal screws  are number 8-32 steel, ground screw is  number 8-32 steel (green). Screw terminal guards are PVC. Listed to UL 498, UL verified to Federal Spec. WC-596G, CSA Certified to C22.2, no. 42. Flammability meets UL 94 requirements; V2.temperature rating: -4 to 158 degrees F. Dielectric voltage: withstands 2000 volts per UL 498. Color coded connectors, black cable. Transfers video signals between components. Molded from non-flammable nylon. Flush fitting, warp resistant design. Screw-catch feature holds mounting screws captive and simplifies installation. Matching screws provided. High gloss finish is soil resistant. Standard size - 2.75" x 4.50", boxed.
Arrow Hart 5131W-BOX Wall Plate Arrow Hart 5131V-BOX Wall Plate AmerTac Zenith CS1001SCRKIT Screen Cleaning Kit
Molded from non-flammable nylon. Flush fitting, warp resistant design. Screw-catch feature holds mounting screws captive and simplifies installation. Matching screws provided. High gloss finish is soil resistant. Standard size - 2.75" x 4.50", boxed. Molded from non-flammable nylon. Flush fitting, warp resistant design. Screw-catch feature holds mounting screws captive and simplifies installation. Matching screws provided. High gloss finish is soil resistant. Standard size - 2.75" x 4.50", boxed. Removes dust and fingerprints without streaking or staining. Works on Plasma, LCD, DLP and 3D TV. Unique tip for reaching corners.
AmerTac Zenith VV3006SVID Type S Video Cable AmerTac CS1001SCRCLR Screen Cleaning Solution AmerTac VN1001MKITRF V Antenna Roof Mounting Kit
Transfers video signals between components. 24K gold connectors. For use with satellite receivers, cable boxes, DVD players, and video recorders. Removes dust and fingerprints without streaking or staining. Works on Plasma, LCD, DLP and 3D TV. 6.7 Fl Oz / 200 Ml. Secures antenna mast to house, roof or attic. Includes: bracket, u-bolt and all needed hardware.
AmerTac Zenith VT1012COMPOS Composite Audio Video Cable Cooper IG8300RN  Duplex Receptacle AmerTac Zenith CD1001DVDCLR Disc Cleaner
Reliable audio/video connection between components. Color coded connectors. Meets all UL 498 "Hospital Grade" requirements, Federal specifications WC-596. Grounding system isolated from common building ground. Triple wipe line contacts provide excellent long-term plug retention. Double wipe ground contacts; one-piece design; reinforced by face and back body to ensure long-term ground retention. High impact-resistant thermoplastic mounting strap, face and back body. Easy access split circuit break-off tab. Automatic ground will ensure wall plate grounding in grounded metal enclosure. Face/body assembled with dual drive pins for superior assembly security. Back and side wire terminals accept #14, #12 or #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. 20 amp, 125 volt. Removes dirt, dust, oil and fingerprints from DVDs and CDs. Helps keep picture and sound quality.
Romex SIMpull 14/2NM-WGX25 Building Wire RECEPT DPLX TAM/RESIST LT ALMD RCPT DPLX GFCI ST 15A/125V BR
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow.
RCPT DPLX GFCI ST 15A/125V BK RCPT DPLX GFCI ST 15A/125V IV RCPT DPLX GFCI ST 15A/125V IV
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow.
RCPT DPLX GFCI ST 15A/125V WH RCPT DPLX GFCI ST 15A/125V WH GFCI DUPLEX 15 LA
GFCI DUPLEX 15 LA
Our Price: $15.04
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow.
Vtech Communications AT210 Trimline Telephones WPLT DEVON WHITE STEEL 1T1R   Vtech VT 6114 Cordless Telephone With Caller ID
Powered by the telephone line, no AC power needed. Speed dial 10 number memory, 3 one-touch memory buttons. Ringer and handset volume control, mute, flash and redial. Hearing aid compatible. Table/wall mountable. 8.5" width x 3" depth x 3.5" height. Weighs 1.5 pounds. In a gift box. Made from stamped steel. - 1 toggle, 1 decorator wallplate. Enhanced 5.8 GHz technology. caller ID/call waiting, voicemail waiting indicator, stores 35 calls. 20 name and number phonebook directory, 9 number speed dial, Any key answer. Large lighted display for easier viewing. Backlit keypad, handset volume control, WiFi friendly. English, Spanish or French prompts. Page/handset locator, selectable ring tones. Wall mount bracket included. 4" x 5.2" x 6.2". In a gift box.
Vtech Communications TR1909 Trimline Telephones Zenith VN1ANTP2 Active Passive 2 Di-Pole TV Antenna Romex SIMpull 12/2NM-WGX25 Building Wire
Powered by the telephone line, no AC power needed. Caller ID/call waiting capability with local subscription. 50 name/number caller ID history, (requires 4 AA batteries, not included). English/Spanish/French setup menu. 13 number memory. Ringer and handset volume control, mute, flash and redial. 2.5" width x 8.27" depth x 2.99" height. Weighs .5 pounds. Table/wall mountable. In a gift box. Passive antenna with VHF and UHF capability. Flexible UHF loop for channels 14 through 69, Full 39" dipole captures VHF broadcast signals on channels 2 through 13. Receives local HDTV broadcast signals for free. Heavy weighted base with 5' coaxial cable and protective bottom. 8.5" height x 5.17" width x 3" depth. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Cooper Wiring TR7735V-BOX Arrow Hart Receptacle/Night Lights Cooper Wiring TR7735W-K-L Arrow Hart Receptacle/Night Lights NIGHTLIGHT/RECEPTACLE LED LA
RECEPTACLE DECORATOR WHT
Our Price: $18.81
Dimmable LED nightlight combination with tamper resistant receptacle for bathrooms, hallways, stairs and landings. Flush-mounted. The nightlight features low wattage LED lamps that consume a maximum of 1 watt of energy, rated for 50,000 hours lamp life. Full dimming as well as 3 preset levels. Sensor turns the nightlight on when ambient light is low, and off when ambient light is high. 15 amp 125 volt AC single pole single receptacle,  1 watt, 120 volt AC nightlight. cULus Listed to UL1472, file no. E47967. Dimmable LED nightlight combination with tamper resistant receptacle for bathrooms, hallways, stairs and landings. Flush-mounted. The nightlight features low wattage LED lamps that consume a maximum of 1 watt of energy, rated for 50,000 hours lamp life. Full dimming as well as 3 preset levels. Sensor turns the nightlight on when ambient light is low, and off when ambient light is high. 15 amp 125 volt AC single pole single receptacle,  1 watt, 120 volt AC nightlight. cULus Listed to UL1472, file no. E47967. Dimmable LED nightlight combination with tamper resistant receptacle for bathrooms, hallways, stairs and landings. Flush-mounted. The nightlight features low wattage LED lamps that consume a maximum of 1 watt of energy, rated for 50,000 hours lamp life. Full dimming as well as 3 preset levels. Sensor turns the nightlight on when ambient light is low, and off when ambient light is high. 15 amp 125 volt AC single pole single receptacle,  1 watt, 120 volt AC nightlight. cULus Listed to UL1472, file no. E47967.
Cooper 1107W Decorator  Duplex Receptacle Cooper 1107V Decorative  Duplex Receptacle RCPT DPLX GFCI ST 20A/125V BR
Longer, wider strap provides 40 percent more contact area to wall board. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire and wire looper for pre-looping. Combination slot/Phillips head mounting and terminal screws for installation with power screwdrivers. Terminal screws backed out - ready for wiring. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no. E15058), Fed. Specs. WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. Longer, wider strap provides 40 percent more contact area to wall board. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire and wire looper for pre-looping. Combination slot/Phillips head mounting and terminal screws for installation with power screwdrivers. Terminal screws backed out - ready for wiring. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no. E15058), Fed. Specs. WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow.
RCPT DPLX GFCI ST 20A/125V BK RCPT DPLX GFCI ST 20A/125V IV RCPT DPLX GFCI ST 20A/125V WH
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow.
GFCI 20A LA                   Romex SIMpull 14/3NM-WGX25 Building Wire RCPT DPLX GFCI TWR ST 15AMP IV
GFCI 20A LA
Our Price: $19.16
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Tamper and weather resistant duplex GFCI, specification grade, back and side wiring. Performs periodic self-tests to ensure integrity of GFCI protection. Visual trip indicator light gives quick notification of a tripped or "end of life" condition. Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Line-load miswiring protection. GFCIs will not provide power when wired incorrectly. UL Listed.
RCPT DPLX GFCI TWR ST 15AMP WH Maestro MS-OPS2H-IV Occupancy Sensor Switch Maestro MS-OPS2H-WH Occupancy Sensor Switch
Tamper and weather resistant duplex GFCI, specification grade, back and side wiring. Performs periodic self-tests to ensure integrity of GFCI protection. Visual trip indicator light gives quick notification of a tripped or "end of life" condition. Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Line-load miswiring protection. GFCIs will not provide power when wired incorrectly. UL Listed. Automatically turn lights on and off with this wall-mounted switch. Turns lights on when anyone enters the room and turns them off when room is vacant. Uses Advanced XCT sensing technology. Up to 900 sq ft of coverage. Also features "Ambient Light Detect" mode: lights won't turn on if there is enough natural light present; user may still manually turn lights on. Works with all bulb types. Requires ground wire. Maximum capacity 150 watts CFL/LED. UL listed. Automatically turn lights on and off with this wall-mounted switch. Turns lights on when anyone enters the room and turns them off when room is vacant. Uses Advanced XCT sensing technology. Up to 900 sq ft of coverage. Also features "Ambient Light Detect" mode: lights won't turn on if there is enough natural light present; user may still manually turn lights on. Works with all bulb types. Requires ground wire. Maximum capacity 150 watts CFL/LED. UL listed.
Maestro MS-VPS2H-WH Vacancy Sensor Switch RCPT DPLX GFCI TR SLFTST15A IV RCPT DPLX GFCI TR SLFTST15A WH
Requires lights to be manually turned on and will automatically turn lights off when the room is vacant. Works with all bulb types and meets California Title 24 and other sensor code requirements. Requires ground wire. UL Listed. Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed.
GFCI TAMPER RESISTANT 15A LA  American Tack and Hdwe VN1001MTRW Zenith Antenna Transformers RECEPT GFCI TR SLF/TST 15A SG
Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Converts antenna style input to coax cable input. 300 to 75 ohm transformer. Rated for outdoor use. Connects to outdoor TV antenna. 2.75" height x .87" width x .87" depth. Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed.
RECEPT GFCI TR SLF/TST 15A ORB RECEPT DPLX SIDE WIRE 15A 125V RCPT DPLX GFCI TR SLFTST20A IV
Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed.
RCPT DPLX GFCI TR SLFTST20A WH GFCI TAMPER RESISTANT 20A LA  WPLT CENTURY AGD BRZ STL 1T 1R
Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Made from stamped steel. - 1 toggle, 1 decorator wallplate.
AmerTac Zenith VC3006COMPON Component Video Cable Romex SIMpull 14/2NM-WGX50 Building Wire Cooper TR7740W-K Combination Electrical Receptacle
Gold-plated 24 carat color coded connectors, silver cables. Protective metal shell. Copper braided reinforced aluminum shielding. Transfers hi-def video signals between components. Plug and play. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Combination dual USB chargers with a tamper resistant AC receptacle. Charge electronic devices directly from a standard outlet without bulky adapters that can be lost or misplaced. LED indicator light shows that device is charging. UL approved Tamper Resistant Shutters to ensure compliance with the 2011 NEC Article 406.12 that requires all 125 volt receptacles in dwelling units to be tamper resistant. Thermoplastic top and back-body are virtually unbreakable. 700mA 5 volt DC USB rating. 15 amp 125 volt NEMA 5-15R receptacle rating. cULus Listed UL 498 and UL1310.
Cooper TR7740V-K Combination Electrical Receptacle RECEPTACLE/USB TAMP/RESIST LA RCPT GFCI TR ST 15AMP 2P3W DS
Combination dual USB chargers with a tamper resistant AC receptacle. Charge electronic devices directly from a standard outlet without bulky adapters that can be lost or misplaced. LED indicator light shows that device is charging. UL approved Tamper Resistant Shutters to ensure compliance with the 2011 NEC Article 406.12 that requires all 125 volt receptacles in dwelling units to be tamper resistant. Thermoplastic top and back-body are virtually unbreakable. 700mA 5 volt DC USB rating. 15 amp 125 volt NEMA 5-15R receptacle rating. cULus Listed UL 498 and UL1310. Combination dual USB chargers with a tamper resistant AC receptacle. Charge electronic devices directly from a standard outlet without bulky adapters that can be lost or misplaced. LED indicator light shows that device is charging. UL approved Tamper Resistant Shutters to ensure compliance with the 2011 NEC Article 406.12 that requires all 125 volt receptacles in dwelling units to be tamper resistant. Thermoplastic top and back-body are virtually unbreakable. 700mA 5 volt DC USB rating. 15 amp 125 volt NEMA 5-15R receptacle rating. cULus Listed UL 498 and UL1310. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. UL Listed.
RCPT DPLX GFCI TWR ST 20AMP IV RCPT DPLX GFCI TWR ST 20AMP WH RCPT GFCI TR ST 15AMP 2P3W SG
Tamper and weather resistant duplex GFCI, specification grade, back and side wiring. Performs periodic self-tests to ensure integrity of GFCI protection. Visual trip indicator light gives quick notification of a tripped or "end of life" condition. Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Line-load miswiring protection. GFCIs will not provide power when wired incorrectly. UL Listed. Tamper and weather resistant duplex GFCI, specification grade, back and side wiring. Performs periodic self-tests to ensure integrity of GFCI protection. Visual trip indicator light gives quick notification of a tripped or "end of life" condition. Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Line-load miswiring protection. GFCIs will not provide power when wired incorrectly. UL Listed. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. UL Listed.
RCPT GFCI TR ST 15AMP 2P3W WS Arrow Hart PJ7V Mid Size Wall Plate Arrow Hart PJ7W Mid Size Wall Plate
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. UL Listed. Virtually unbreakable, with high structural rigidity, long-term form retention and impact and abrasion resistance. Screw-catch feature holds mounting screws captive. Matching screws provided. High gloss finish is soil resistant. Mid-size - 3.125" x 4.875". Virtually unbreakable, with high structural rigidity, long-term form retention and impact and abrasion resistance. Screw-catch feature holds mounting screws captive. Matching screws provided. High gloss finish is soil resistant. Mid-size - 3.125" x 4.875".
RECEPTACLE DUPLEX 2P 3W 15 LA American Tack and Hdwe VR3001SWHD Zenith HDMI Selector Switches AmerTac VN1075MRW V Antenna Rotator Wire
Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed. Allows manual switching between 3 different HDMI input sources. No signal loss, 1080p transmission. Allows HDTVs with only one HDMI input to receive 3 input sources. 24K gold connectors. Connects antenna rotator motor drive to controller unit.
Vtech Communications AT2909 ATT Telephones RCPT DPLX AFCI TR 15A/125V WH RCPT DPLX AFCI TR 15A/125V IV
Speakerphone, 14 number memory, hold, redial, flash and mute. Line powered, No AC power needed. English/Spanish/French setup menu, caller ID/call waiting capability, 65 name/number caller ID history, remove button and display dial. 6.75" width x 8.75" depth x 3.75" height. Weighs 1.5 pounds. In a gift box. Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards. Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards.
RCPT DPLX AFCI TR 15A/125V LA SENSOR OCCUPANCY              Cooper OS306U-V-K Standard Occupancy/Vacancy Sensor Switch
SENSOR OCCUPANCY
Our Price: $26.89
Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards. Replaces a standard light or fan switch. Works with Incandescent, Halogen, Fluorescent, LED, CFL, MLV and ELV lights. Status LED indicator. Sensors provide up to 180 degree field of view and 450 square feet of major motion coverage. Selectable time delay of 5 seconds to 30 minutes for lights to remain on after room is vacated. No neutral required for installation. Can be wired as a single-pole or 3-way. Electrostatic discharge protection. Suitable for multi-gang installations. Compatible with decorator-style wallplates and designer screwless wallplates. 120 volts AC, 60Hz, 1/6 HP. Replaces a standard light or fan switch. Works with Incandescent, Halogen, Fluorescent, LED, CFL, MLV and ELV lights. Status LED indicator. Sensors provide up to 180 degree field of view and 450 square feet of major motion coverage. Selectable time delay of 5 seconds to 30 minutes for lights to remain on after room is vacated. No neutral required for installation. Can be wired as a single-pole or 3-way. Electrostatic discharge protection. Suitable for multi-gang installations. Compatible with decorator-style wallplates and designer screwless wallplates. 120 volts AC, 60Hz, 1/6 HP.
Cooper OS306U-W-K Standard Occupancy/Vacancy Sensor Switch LIGHT NIGHT GFCI IVORY 15A    LIGHT NIGHT GFCI WHITE 15A
Replaces a standard light or fan switch. Works with Incandescent, Halogen, Fluorescent, LED, CFL, MLV and ELV lights. Status LED indicator. Sensors provide up to 180 degree field of view and 450 square feet of major motion coverage. Selectable time delay of 5 seconds to 30 minutes for lights to remain on after room is vacated. No neutral required for installation. Can be wired as a single-pole or 3-way. Electrostatic discharge protection. Suitable for multi-gang installations. Compatible with decorator-style wallplates and designer screwless wallplates. 120 volts AC, 60Hz, 1/6 HP. Automatic testing GFCI receptacle with nightlight. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant, contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. Specification grade. 2-pole, 3-wire grounding. UL Listed. Automatic testing GFCI receptacle with nightlight. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant, contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. Specification grade. 2-pole, 3-wire grounding. UL Listed.
GFCI/NIGHTLIGHT TAMP/RESIS 15A Cooper Wiring TR7745W-K Commercial Spec Grade USB Receptacle Cooper Wiring TR7745V-K Commercial Spec Grade USB Receptacle
Automatic testing GFCI receptacle with nightlight. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant, contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. Specification grade. 2-pole, 3-wire grounding. UL Listed. USB, duplex receptacle. Specification grade device is built to withstand the tough demands of the commercial environment. Dual USB charging ports charge most compatible electronic devices that charge via a 5V charger adapter. Duplex receptacles with tamper resistant shutters. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used. Thermoplastic top and back-body are virtually unbreakable to deliver years of durable performance. Three (3) pre-stripped 6" wire leads for line, neutral and ground for quick and easy installation. Steel mounting strap is zinc-plated for added corrosion resistance. USB, duplex receptacle. Specification grade device is built to withstand the tough demands of the commercial environment. Dual USB charging ports charge most compatible electronic devices that charge via a 5V charger adapter. Duplex receptacles with tamper resistant shutters. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used. Thermoplastic top and back-body are virtually unbreakable to deliver years of durable performance. Three (3) pre-stripped 6" wire leads for line, neutral and ground for quick and easy installation. Steel mounting strap is zinc-plated for added corrosion resistance.
RECEPT/USB DPLX TAMP/RESIST LA AmerTac Zenith VC3012COMPON Component Video Cable Vtech Communications CS6124 Cordless Telephones
USB, duplex receptacle. Specification grade device is built to withstand the tough demands of the commercial environment. Dual USB charging ports charge most compatible electronic devices that charge via a 5V charger adapter. Duplex receptacles with tamper resistant shutters. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used. Thermoplastic top and back-body are virtually unbreakable to deliver years of durable performance. Three (3) pre-stripped 6" wire leads for line, neutral and ground for quick and easy installation. Steel mounting strap is zinc-plated for added corrosion resistance. Gold-plated 24 carat color coded connectors, silver cables. Protective metal shell. Copper braided reinforced aluminum shielding. Transfers hi-def video signals between components. Plug and play. Enhanced 5.8 GHz technology. caller ID/call waiting, stores 30 calls. 30 name and number phonebook directory, 9 number speed dial, Any key answer. Large lighted display for easier viewing. Backlit keypad, handset volume control, WiFi friendly. English, Spanish or French prompts. Page/handset locator, selectable ring tones. Digital answering system, no tapes or moving parts. Remote message retrieval, 11 minutes of recording time, Audible time and date stamp on recorded messages. Backlit message counter. 5.6" x 6" x 6.1". Wall mount bracket included.
RCPT DPLX AFCI TR 20A/125V WH RCPT DPLX AFCI TR 20A/125V IV RCPT DPLX AFCI TR 20A/125V LA
Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards. Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards. Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards.
RECEPT DUPLX B/S-WIRE 15A 125V RCPT DPLX AF/GF TR LA 15A 125V RCPT DPLX AF/GF TR IV 15A 125V
High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed. Duplex self-test AF/GF with standard-size wallplate, back and side wired. 15A/125V NEMA 5-15R. 2-pole, 3-wire grounding. Wire size number 14 - 10 AWG. Both arc fault protection and ground fault protection.  Provides protection from series arcs, parallel arcs, and ground faults. Self-test GFCI technology. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Ground termination with back wire clamp. Automatic grounding system eliminates the need for bonding jumper in grounded metal enclosure. Tapered back wire openings handle multiple wire sizes and types for applications up to number 10 AWG solid or stranded wire. Lock-out functionality prevents mis-wired line-load connections and GFCI/AFCI circuitry damage. Visual indicator light provides quick visual reference of a tripped or end of life condition. Tamper resistant (TR) shutters comply with 2014 NEC Article 406.12. Terminal screws backed out and ready to wire. Matching standard size thermoplastic wallplate included. Duplex self-test AF/GF with standard-size wallplate, back and side wired. 15A/125V NEMA 5-15R. 2-pole, 3-wire grounding. Wire size number 14 - 10 AWG. Both arc fault protection and ground fault protection.  Provides protection from series arcs, parallel arcs, and ground faults. Self-test GFCI technology. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Ground termination with back wire clamp. Automatic grounding system eliminates the need for bonding jumper in grounded metal enclosure. Tapered back wire openings handle multiple wire sizes and types for applications up to number 10 AWG solid or stranded wire. Lock-out functionality prevents mis-wired line-load connections and GFCI/AFCI circuitry damage. Visual indicator light provides quick visual reference of a tripped or end of life condition. Tamper resistant (TR) shutters comply with 2014 NEC Article 406.12. Terminal screws backed out and ready to wire. Matching standard size thermoplastic wallplate included.
RCPT DPLX AF/GF TR WH 15A 125V RECEPT DUPLEX DECO LA         RCPT/SWTCH GFCI MD WLPLT15A IV
RECEPT DUPLEX DECO LA
Our Price: $30.56
Duplex self-test AF/GF with standard-size wallplate, back and side wired. 15A/125V NEMA 5-15R. 2-pole, 3-wire grounding. Wire size number 14 - 10 AWG. Both arc fault protection and ground fault protection.  Provides protection from series arcs, parallel arcs, and ground faults. Self-test GFCI technology. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Ground termination with back wire clamp. Automatic grounding system eliminates the need for bonding jumper in grounded metal enclosure. Tapered back wire openings handle multiple wire sizes and types for applications up to number 10 AWG solid or stranded wire. Lock-out functionality prevents mis-wired line-load connections and GFCI/AFCI circuitry damage. Visual indicator light provides quick visual reference of a tripped or end of life condition. Tamper resistant (TR) shutters comply with 2014 NEC Article 406.12. Terminal screws backed out and ready to wire. Matching standard size thermoplastic wallplate included. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. With toggle switch. Includes mid-size wall plate. Rating 15 amp, 125 volts, NEMA 5-15R. UL Listed.
WALLPLATE SWITCH COMBO GFCI/SP GFCI SWITCH 1POLE LA          Maestro MS-OPS5M-IV 3-Way Occupancy Sensor Switch
GFCI SWITCH 1POLE LA
Our Price: $31.51
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. With toggle switch. Includes mid-size wall plate. Rating 15 amp, 125 volts, NEMA 5-15R. UL Listed. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. With toggle switch. Includes mid-size wall plate. Rating 15 amp, 125 volts, NEMA 5-15R. UL Listed. Automatically turn lights on and off with this wall-mounted switch. turns lights on when anyone enters the room and turns them off when vacant. Detects motions of room occupants. Uses Advanced XCT sensing technology. up to 900 sq ft of coverage. Also features "Ambient Light Detect" mode: lights won't turn on if there is enough natural light present; user may still manually turn lights on. Works with all bulb types. Requires ground wire.
Maestro MS-OPS5M-WH 3-Way Occupancy Sensor Switch Maestro MS-VPS5MH-WH 3-Way Vacancy Sensor Switch Romex SIMpull 10/2NM-WGX25 Building Wire
Automatically turn lights on and off with this wall-mounted switch. turns lights on when anyone enters the room and turns them off when vacant. Detects motions of room occupants. Uses Advanced XCT sensing technology. up to 900 sq ft of coverage. Also features "Ambient Light Detect" mode: lights won't turn on if there is enough natural light present; user may still manually turn lights on. Works with all bulb types. Requires ground wire. Requires lights to be manually turned on and will automatically turn lights off when the room is vacant. Works with all bulb types and meets California Title 24 and other sensor code requirements. Requires ground wire. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/3NM-WGX25 Building Wire Romex SIMpull 14/2NM-WGX100 Building Wire American Tack and Hdwe VR1001RFMDS Zenith RF Modulators
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Connects components with RCA plugs to a TV with a single coaxial input. Has an S-Video input. Stereo capable. 5.75" height x 3.25" width x 2" depth.
Romex SIMpull 12/2NM-WGX50 Building Wire American Tack and Hdwe VN1ANTA15 Zenith Indoor Tv Antennas Core Savant OS310U-W-K Motion Sensor Switch
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. High gain low noise wide band amplifier. Flat design offers 2-way positioning for best reception. Amplifier boosts signal strength for increased picture quality. Receives local HD and Digital TV broadcast signals.  Blue power indicator light. 6.75" height x 7" width x 1.17" depth. Includes power adapter and 58" coax cable. For incandescent, Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), fluorescent, compact fluorescent, LED and motors up to 1/6 HP. Includes selectable and dimmable nightlight. Turns on automatically when a person enters the room, automatically turn off lights after a selectable time delay of 5 seconds (Test Mode), 5 minutes (factory default), 15 minutes and 30 minutes. Detects when the room is occupied very briefly and shortens the time delay in order to save energy,  includes a light level adjustment for daylight to prevent motion from turning on the lights.  Provides 180 degree field of view and 1000 square feet of major motion coverage. Includes a decorator mid-size wallplate. A green LED indicates load status, provides locator light in dark and blinks to indicate motion detection. 8.3 amp, 1000 watts, 120 volts AC, 60 Hz. 6" pre-stripped wire leads, #14 AWG. cULus Listed, NOM Certified, California Title 24 Compliant. Temperature rating 32 to 104 degrees F.
Core Savant OS310U-V-K Motion Sensor Switch SENSOR SWITCH OCCUPANCY       Romex SIMpull 14/3NM-WGX50 Building Wire
SENSOR SWITCH OCCUPANCY
Our Price: $36.22
For incandescent, Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), fluorescent, compact fluorescent, LED and motors up to 1/6 HP. Includes selectable and dimmable nightlight. Turns on automatically when a person enters the room, automatically turn off lights after a selectable time delay of 5 seconds (Test Mode), 5 minutes (factory default), 15 minutes and 30 minutes. Detects when the room is occupied very briefly and shortens the time delay in order to save energy,  includes a light level adjustment for daylight to prevent motion from turning on the lights.  Provides 180 degree field of view and 1000 square feet of major motion coverage. Includes a decorator mid-size wallplate. A green LED indicates load status, provides locator light in dark and blinks to indicate motion detection. 8.3 amp, 1000 watts, 120 volts AC, 60 Hz. 6" pre-stripped wire leads, #14 AWG. cULus Listed, NOM Certified, California Title 24 Compliant. Temperature rating 32 to 104 degrees F. For incandescent, Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), fluorescent, compact fluorescent, LED and motors up to 1/6 HP. Includes se