Halex 90440 Screw-In Connector Halex 90441 Screw-In Connector Halex 90451 Screw-In Coupling
Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. Zinc die cast. Use to join two pieces of flexible metallic conduit (Greenfield) together.
Halex 91530 Combination Coupling Halex 90580 Cable Connector Halex 90510 Twin Screw Clamp Connector
Zinc die cast. Use to join EMT conduit to non-metallic sheathed cable. #14/2, #12/3 or 2 #14/2. Indoor use only. With UPC. UL Approved. Zinc die cast. In a dry location, use to connect BX cable to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved. Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements.
Halex 90481 Concrete Tight Set Screw Connector Halex 90570 Combination Clamp Connector Halex 96510 2-Piece Butterfly Clamp Connector
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. UL Approved. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield, BX, NM or Metal Clad) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved. Zinc die cast. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required.
Halex 90442 Screw-In Connector Halex 91100 Conduit Elbow Halex 90420 Squeeze Connector
Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved.
Halex 65705B Snap-In Cable Connector Halex 90512 Twin Screw Clamp Connector Halex 27511 Hit Lock Cable Connectors
In a dry location, use to connect aluminum or steel AC, aluminum MC, and steel flexible metal conduit. Suitable for: aluminum and steel armored cable with 14/2 - 10/2 wire, steel flexible metal conduit, .45 diameter aluminum interlocked MC cable. Features snap-in installation, no locknut, insulating bushing included. Fits non metallic cable, such as Romex, number 14/2 round, number 12/3-8/3 AWG or flex cord .460 to .720 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified.
Halex 90421 Squeeze Connector Halex 75403 Anti-Short Conduit Bushing CONNECTOR DPLX FLX N-MTL 3/8IN
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL Approved. No. 75400 - Fits cable range: 14/2, 14/3, 12/2 No. 75401 - Fits cable range: 14/4, 12/3, 6/1, 4/1. No. 75402 - Fits cable range: 12/4, 10/2, 10/3, 2/1. No. 75403 - Fits cable range: 10/4, 8/2, 8/3, 1/1. No. 75404 - Fits cable range: 8/4, 6/2, 6/3, 4/2, 4/3, 6/4. In a dry location, use to connect two pieces of flexible armored cable (Greenfield or BX) to a steel outlet box or other metal enclosure, when using only one knock-out opening. UL Approved.
Halex 91531 Combination Coupling Halex 90513 Twin Screw Clamp Connector Halex 90422 Squeeze Connector
Zinc die cast. Use to join EMT conduit to flexible metal conduit. Indoor use only. With UPC. UL Approved. Fits non metallic cable number 14/2 to number 6/3 AWG or number 3/10/3 AWG or flex cord .450 to .730 inches diameter. With a 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved.
Halex 20511 Twin Screw Clamp Connector Halex 91101 Conduit Elbow Halex 90514 Twin Screw Clamp Connector
Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. Fits non metallic cable number 6/3 to number 2/3 AWG flex cord .800 to 1.350 inches diameter or SE cable 3 conductor or 3 number 1/0 minimum; 3 conductor or 3 number 2/0 maximum. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements.
Halex 75400 Anti-Short Conduit Bushing Halex 90452 Screw-In Coupling Halex 11005B Conduit Elbow
High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL Approved. No. 75400 - Fits cable range: 14/2, 14/3, 12/2 No. 75401 - Fits cable range: 14/4, 12/3, 6/1, 4/1. No. 75402 - Fits cable range: 12/4, 10/2, 10/3, 2/1. No. 75403 - Fits cable range: 10/4, 8/2, 8/3, 1/1. No. 75404 - Fits cable range: 8/4, 6/2, 6/3, 4/2, 4/3, 6/4. Zinc die cast. Use to join two pieces of flexible metallic conduit (Greenfield) together. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure.
Halex 20581 Cable Connector Halex 75401 Anti-Short Conduit Bushing Halex 91102 Pull Conduit Elbow
In a dry location, use to connect AC (BX) cable to a steel outlet box or other metal enclosure. Suitable for #14-2 steel armored cable. High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL Approved. No. 75400 - Fits cable range: 14/2, 14/3, 12/2 No. 75401 - Fits cable range: 14/4, 12/3, 6/1, 4/1. No. 75402 - Fits cable range: 12/4, 10/2, 10/3, 2/1. No. 75403 - Fits cable range: 10/4, 8/2, 8/3, 1/1. No. 75404 - Fits cable range: 8/4, 6/2, 6/3, 4/2, 4/3, 6/4. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure.
Halex 27519 Hit Lock Cable Connectors Halex 75402 Anti-Short Conduit Bushing Halex 05115 Twin Screw Clamp Connector
Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified. High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL Approved. No. 75400 - Fits cable range: 14/2, 14/3, 12/2 No. 75401 - Fits cable range: 14/4, 12/3, 6/1, 4/1. No. 75402 - Fits cable range: 12/4, 10/2, 10/3, 2/1. No. 75403 - Fits cable range: 10/4, 8/2, 8/3, 1/1. No. 75404 - Fits cable range: 8/4, 6/2, 6/3, 4/2, 4/3, 6/4. Fits non metallic cable, flex cords, multi flex cords; fitting range .834 - 1.520 inches diameter SE cables 2 conductor 4/0. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Tray boxed.
Halex 27512 Hit Lock Cable Connectors Halex 26512 2-Piece Butterfly Clamp Connector Halex 20491 Combination Coupling
Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified. Zinc die cast. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required. Use to joint EMT conduit to flexible metal conduit. Die cast zinc. UL Approved, CSA Certified.
Halex 05120 Twin Screw Clamp Connector Halex 20510 Twin Screw Clamp Connector Halex 20512 Twin Screw Clamp Connector
Fits non metallic cable, flex cords, multi flex cords fitting range 1.085 - 1.520 inches diameter. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Tray boxed. Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements. Fits non metallic cable, such as Romex, number 14/2 round, number 12/3-8/3 AWG or flex cord .460 to .720 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements.
Halex 26571 Flexible MC Snap-In Connector Halex 04212 Squeeze Connector Halex 20492 Combination Coupling
Halex MC Snap-In Connector, Flexible, 3/8 in Nominal, Steel, Includes: Insulating Bushing, CSA Certified, UL Listed, For use to connect aluminum or steel ac, aluminum mc, and steel flexible metal conduit, indoor use only Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. Use to joint EMT conduit to flexible metal conduit. Die cast zinc. UL Approved, CSA Certified.
BULB LED BR30 65W EQUIV NONDIM LED BR30 8.5W/65W MED BS 2700K LED GROW LT A19 9WRED ENRICHED
Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Non-dimmable A19 LED grow light lasts up to 25,000 hours, Red spectrum enriched for budding and flowering. Emits more light in the useful 450nm blue and 655nm red spectrum than regular white LED bulbs. Rated for high humidity use. Instant full brightness. 9 watts, 120 volts, UL/CUL Listed, FCC Compliant. 4.5" length x 2.25" diameter.
Halex 75105B Hit Lock Cable Connectors Halex 27515 Cable Connectors BR30 GROW LT MED BASE 9W LED
Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified. Push-in style with captive locking wedge. Rigid PVC. Superior strain relief and insulation. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. Fits NM cable #14/2 - #10/3. Fits 1/2" knock outs. UL, CSA Listed. Non-dimmable BR30 LED grow light lasts up to 25,000 hours and is red spectrum enriched for budding and flowering. Rated for high humidity use. Emits more light in the useful 450nm blue and 655nm red spectrum than regular white LED bulbs. Instant on to full brightness. UL/CUL Listed, FCC Compliant, Mercury free. 5"H x 3.75"D.
BULB BIG LED 2570L EDISON BASE CONNECTOR 90DEG 3/8IN 35/CTN  Halex 04210 Squeeze Connector
Edison medium base. 4000K, 25,000 hours average life. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved.
BULB LED UTILITY 1500 LUMEN   Halex 05803B Snap-In Cable Connector Halex 15803B Duplex Connector
LED utility bulb offers 30,000 hours of LED life, heavy duty, aluminum reflector. 8.75" in diameter. Includes 3 pieces. Zinc die cast. In a dry location, use to connect BX cable to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved. In a dry location, use to connect two pieces of flexible armored cable (Greenfield or BX) to a steel outlet box or other metal enclosure, when using only one knock-out opening. UL Approved.
Halex 05112B Twin Screw Clamp Connector Halex 05103B Twin Screw Clamp Connector Halex 05110B Twin Screw Clamp Connector
Fits non metallic cable number 6/3 to number 2/3 AWG flex cord .800 to 1.350 inches diameter or SE cable 3 conductor or 3 number 1/0 minimum; 3 conductor or 3 number 2/0 maximum. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements. Fits non metallic cable number 14/2 to number 6/3 AWG or number 3/10/3 AWG or flex cord .450 to .730 inches diameter. With a 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements.
BULB LED 38W 5000K 300W EQUIV BULB BIG LED 4275L EDISON BASE Halex 05107B Twin Screw Clamp Connector
High powered 38 watt LED light is a direct replacement for a 300 watt incandescent. Used for yard light, light socket and barn light. It has an average life of 35,000 hours and is 4000 lumens, 5000K and 120V. 8.5"H x 3"D. Instant on to full brightness. UL Listed, FCC Compliant and is 100 percent mercury free. Edison medium base. 4000K, 25,000 hours average life. Fits non metallic cable, such as Romex, number 14/2 round, number 12/3-8/3 AWG or flex cord .460 to .720 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements.
Halex 04205B Squeeze Connector Halex 05703B Combination Clamp Connector Halex 11007B Conduit Elbow
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield, BX, NM or Metal Clad) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure.
Halex 04207B Squeeze Connector Halex 04203B Squeeze Connector YARD LT 100W/500W MED LED5000K
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. Non-Dimmable 100 watt, 120 volt medium base 5000K LED yard light is a direct replacement for a 500 watt incandescent. Average life of 25,000 hours. Instant on to full brightness, suitable for damp locations. UL Listed, FCC Compliant and mercury free. 8.5"H x 3"D.
Southwire 6SOLX315BARE Solid Electrical Wire Southwire 8SOLX500BARE Solid Electrical Wire Southwire 6STRDX315BARE Stranded Electrical Wire
Equipment and circuit grounding. Equipment and circuit grounding. Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems.
Southwire 4STRDX200BARE Stranded Electrical Wire Southwire 4SOLX200BARE Solid Electrical Wire Southwire 2SOLX125BARE Solid Electrical Wire
Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems. Equipment and circuit grounding. Equipment and circuit grounding.
Southwire 10SOLX800BARE Linear Electrical Wire
Equipment and circuit grounding.
   
 
1