Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE > ARMORED CABLE
Sort By:
1
Halex 90440 Screw-In Connector Halex 90441 Screw-In Connector Halex 90451 Screw-In Coupling
Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. Zinc die cast. Use to join two pieces of flexible metallic conduit (Greenfield) together.
Halex 90510 Twin Screw Clamp Connector Halex 91530 Combination Coupling Halex 90580 Cable Connector
Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements. Zinc die cast. Use to join EMT conduit to non-metallic sheathed cable. #14/2, #12/3 or 2 #14/2. Indoor use only. With UPC. UL Approved. Zinc die cast. In a dry location, use to connect BX cable to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved.
Halex 90481 Concrete Tight Set Screw Connector Halex 90570 Combination Clamp Connector Halex 96510 2-Piece Butterfly Clamp Connector
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. UL Approved. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield, BX, NM or Metal Clad) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved. Zinc die cast. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required.
Halex 90442 Screw-In Connector Halex 90512 Twin Screw Clamp Connector Halex 91100 Conduit Elbow
Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. Fits non metallic cable, such as Romex, number 14/2 round, number 12/3-8/3 AWG or flex cord .460 to .720 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure.
Halex 90420 Squeeze Connector Halex 65705B Snap-In Cable Connector Halex 27511 Hit Lock Cable Connectors
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. In a dry location, use to connect aluminum or steel AC, aluminum MC, and steel flexible metal conduit. Suitable for: aluminum and steel armored cable with 14/2 - 10/2 wire, steel flexible metal conduit, .45 diameter aluminum interlocked MC cable. Features snap-in installation, no locknut, insulating bushing included. Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified.
Halex 90421 Squeeze Connector Halex 75403 Anti-Short Conduit Bushing CONNECTOR DPLX FLX N-MTL 3/8IN
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL Approved. No. 75400 - Fits cable range: 14/2, 14/3, 12/2 No. 75401 - Fits cable range: 14/4, 12/3, 6/1, 4/1. No. 75402 - Fits cable range: 12/4, 10/2, 10/3, 2/1. No. 75403 - Fits cable range: 10/4, 8/2, 8/3, 1/1. No. 75404 - Fits cable range: 8/4, 6/2, 6/3, 4/2, 4/3, 6/4. In a dry location, use to connect two pieces of flexible armored cable (Greenfield or BX) to a steel outlet box or other metal enclosure, when using only one knock-out opening. UL Approved.
Halex 20511 Twin Screw Clamp Connector Halex 91531 Combination Coupling Halex 90513 Twin Screw Clamp Connector
Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements. Zinc die cast. Use to join EMT conduit to flexible metal conduit. Indoor use only. With UPC. UL Approved. Fits non metallic cable number 14/2 to number 6/3 AWG or number 3/10/3 AWG or flex cord .450 to .730 inches diameter. With a 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements.
Halex 90422 Squeeze Connector Halex 91101 Conduit Elbow Halex 90514 Twin Screw Clamp Connector
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. Fits non metallic cable number 6/3 to number 2/3 AWG flex cord .800 to 1.350 inches diameter or SE cable 3 conductor or 3 number 1/0 minimum; 3 conductor or 3 number 2/0 maximum. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements.
Halex 75400 Anti-Short Conduit Bushing Halex 90452 Screw-In Coupling Halex 11005B Conduit Elbow
High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL Approved. No. 75400 - Fits cable range: 14/2, 14/3, 12/2 No. 75401 - Fits cable range: 14/4, 12/3, 6/1, 4/1. No. 75402 - Fits cable range: 12/4, 10/2, 10/3, 2/1. No. 75403 - Fits cable range: 10/4, 8/2, 8/3, 1/1. No. 75404 - Fits cable range: 8/4, 6/2, 6/3, 4/2, 4/3, 6/4. Zinc die cast. Use to join two pieces of flexible metallic conduit (Greenfield) together. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure.
Halex 20581 Cable Connector Halex 75401 Anti-Short Conduit Bushing Halex 91102 Pull Conduit Elbow
In a dry location, use to connect AC (BX) cable to a steel outlet box or other metal enclosure. Suitable for #14-2 steel armored cable. High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL Approved. No. 75400 - Fits cable range: 14/2, 14/3, 12/2 No. 75401 - Fits cable range: 14/4, 12/3, 6/1, 4/1. No. 75402 - Fits cable range: 12/4, 10/2, 10/3, 2/1. No. 75403 - Fits cable range: 10/4, 8/2, 8/3, 1/1. No. 75404 - Fits cable range: 8/4, 6/2, 6/3, 4/2, 4/3, 6/4. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure.
Halex 27519 Hit Lock Cable Connectors Halex 75402 Anti-Short Conduit Bushing Halex 05115 Twin Screw Clamp Connector
Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified. High dielectric plastic. Use to protect wire within flexible metallic conduit (Greenfield, BX). Insert one bushing at each end of conduit. UL Approved. No. 75400 - Fits cable range: 14/2, 14/3, 12/2 No. 75401 - Fits cable range: 14/4, 12/3, 6/1, 4/1. No. 75402 - Fits cable range: 12/4, 10/2, 10/3, 2/1. No. 75403 - Fits cable range: 10/4, 8/2, 8/3, 1/1. No. 75404 - Fits cable range: 8/4, 6/2, 6/3, 4/2, 4/3, 6/4. Fits non metallic cable, flex cords, multi flex cords; fitting range .834 - 1.520 inches diameter SE cables 2 conductor 4/0. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Tray boxed.
Halex 27512 Hit Lock Cable Connectors Halex 26512 2-Piece Butterfly Clamp Connector Halex 20510 Twin Screw Clamp Connector
Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified. Zinc die cast. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required. Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements.
Halex 20491 Combination Coupling Halex 20512 Twin Screw Clamp Connector Halex 05120 Twin Screw Clamp Connector
Use to joint EMT conduit to flexible metal conduit. Die cast zinc. UL Approved, CSA Certified. Fits non metallic cable, such as Romex, number 14/2 round, number 12/3-8/3 AWG or flex cord .460 to .720 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Fits non metallic cable, flex cords, multi flex cords fitting range 1.085 - 1.520 inches diameter. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Tray boxed.
BULB LED BR30 8.5W 2700K      Halex 26571 Flexible MC Snap-In Connector Halex 04212 Squeeze Connector
Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Halex MC Snap-In Connector, Flexible, 3/8 in Nominal, Steel, Includes: Insulating Bushing, CSA Certified, UL Listed, For use to connect aluminum or steel ac, aluminum mc, and steel flexible metal conduit, indoor use only Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved.
Feit R20/DM/LED Dimmable LED Lamp LED R20 850 DIM 5000K         BULB LED R20 DIM 6W 2700K
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Ultra LED, directional. Dimmable, medium aluminum base.
Feit BR30/DM/LED Dimmable LED Lamp Feit BR30/DM/5K/LED Dimmable LED Lamp BULB LED BR30 DIM 9W 5000K
Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Medium base, 120 volt, 25,000 hours average life.
Feit BPR14DM/LED Dimmable LED Lamp Halex 20492 Combination Coupling Feit BPR16DM/LED Dimmable LED Lamp
For track lighting. 120 volts, 2700K, 105 degree beam angle, 25,000 average life hours. Instant on to full brightness. Use to joint EMT conduit to flexible metal conduit. Die cast zinc. UL Approved, CSA Certified. For track lighting. 120 volts, 2700K, 105 degree beam angle, 25,000 average life hours. Instant on to full brightness.
BULB LED BR30 65W EQ DIMMABLE BULB LED BR30 65W EQ DIMMABLE LED R20 7.5W/45W MED DIM 2700K
Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
R20 7.5W/45W MED DIM  LED5000K LED7.5BR30DIM 7.5/65W EQV 5K  BULB LED 10YR 65W BR30 27K 2PK
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Medium base, 120 volt, 25,000 hours average life. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant.
BULB LIGHT LED 10YR BR30 60W  BULB LED BR30 10YR DIM35K 65W Feit 17BR40/DM/LED Dimmable LED Lamp
Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. For track lighting. Instant on to full brightness. Suitable for damp locations. 25,000 average life hours. 120 volt, 110 degree beam spread. FCC Compliant. 100 percent mercury free.
BULB LED BR40 DIM 12W 2700K   LED BR40 927 15.5W DIM 2700K  BULB LED R20 45W EQUIV NON-DIM
Medium base, 120 volt, 25,000 hours average life. For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
BULB LED R20 10YR DIM 27K 50W BULB LED R20 10YR DIM 5K 50W  BULB LED R20 10YR DIM 35K 50W
Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant.
BULB LED BR40 DIM 12W 5000K   BULB LED BR40 DIM 12W 3500K   BULB LED 65W BR30 E26 27K 650L
Medium base, 120 volt, 25,000 hours average life. Medium base, 120 volt, 25,000 hours average life. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free.
Southwire 55082415 Armored Cable Feit BPMR11/LED Non-Dimmable LED Lamp BULB LED INTGRTD 27K 15W/65W
Wire whip, 14/3 AWG. Performance LED, for track lighting. 12 volt, 240 lumens, 3000K, 38 degree beam angle, 25,000 average life hours. 1.5" MOL x 1.35" diameter. Instant on to full brightness. Suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant. Mercury free. Dimmable, 11,000 average life hours. E26 medium base.
LED BR40 10.5W/65W MED DIM 5K BULB LED PAR20 10YR 3K 50W    LED PAR38 10.5W/75W MED 3000K
For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. Medium base, non dimmable, 11000 hours average life. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
Halex 75105B Hit Lock Cable Connectors BULB LED BR40 DIMMABLE 5000K  BULB LED BR40 DIMMABLE 2700K
Fits NM Cable: #14/2, #14/3, #12/2, #10/2, #10/3. Snap-In, no screws or locknuts required. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box or other metal enclosure. Design allows for two-step installation. Push into box and insert cable. UL Approved, CSA certified. For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free.
Halex 27515 Cable Connectors BULB LED PAR20 50WATT NON-DIM BULB LED NON-DIMM PAR20 5K 3PK
Push-in style with captive locking wedge. Rigid PVC. Superior strain relief and insulation. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. Fits NM cable #14/2 - #10/3. Fits 1/2" knock outs. UL, CSA Listed. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
LED12PAR38 FLOOD E26 3K 1100L Armorlite 68580021 Type MC Armored Cable Armorlite 68579221 Type MC Armored Cable
Ultra LED, directional. Dimmable, E26 medium base. 25,000 hours average life. RoHS compliant, contain no mercury, lead or other hazardous materials and emit no UV or IR radiation. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
BULB LED BR40 HO35K 11K-HR 85W BULB LED BR40 HO5K 13/85W     BULB LED PAR30 LN 10YR 3K 65W
Medium base, non dimmable, 11000 hours average life. Medium base, non dimmable, 11000 hours average life. Medium base, non dimmable, 11000 hours average life.
BULB LED BR30 65W DIMMABLE    BULB LED BR40 DIM 27K 13W/85W BULB LED BR40 DIM 5K 13W/85W
Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant.
Duraclad 55278321 Type MC Armored Cable Feit BR40/DM/2500/3K/L Dimmable LED Lamp Duraclad 55274921 Type MC Armored Cable
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. For track lighting. Instant on to full brightness. Suitable for damp locations. 25,000 average life hours. 120 volt, 110 degree beam spread. FCC Compliant. 100 percent mercury free. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
BULB LED PAR38 3000K 13W/90W  BULB LED PAR38 5000K 13W/90W  BULB LED PAR30L 75WATT NON-DIM
Medium base, non dimmable, 11000 hours average life. Medium base, non dimmable, 11000 hours average life. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
CONNECTOR 90DEG 3/8IN 35/CTN  Halex 05103B Twin Screw Clamp Connector Halex 04210 Squeeze Connector
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. Fits 1/2" knockout, non-metallic cable numbers 14/2, 12/2, 12/3 AWG or 2 number 14/2 AWG or flex cord .300 to .560 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL, Listed, meets CSA requirements. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved.
Halex 05803B Snap-In Cable Connector Halex 15803B Duplex Connector Halex 05112B Twin Screw Clamp Connector
Zinc die cast. In a dry location, use to connect BX cable to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved. In a dry location, use to connect two pieces of flexible armored cable (Greenfield or BX) to a steel outlet box or other metal enclosure, when using only one knock-out opening. UL Approved. Fits non metallic cable number 6/3 to number 2/3 AWG flex cord .800 to 1.350 inches diameter or SE cable 3 conductor or 3 number 1/0 minimum; 3 conductor or 3 number 2/0 maximum. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements.
Armorlite 68579222 Type MC Armored Cable Halex 05110B Twin Screw Clamp Connector Armorlite 68583421 Type MC Armored Cable
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Fits non metallic cable number 14/2 to number 6/3 AWG or number 3/10/3 AWG or flex cord .450 to .730 inches diameter. With a 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Halex 05107B Twin Screw Clamp Connector Duraclad 55274922 Type MC Armored Cable Duraclad 55278521 Type MC Armored Cable
Fits non metallic cable, such as Romex, number 14/2 round, number 12/3-8/3 AWG or flex cord .460 to .720 inches diameter. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requirements. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Duraclad 55275021 Type MC Armored Cable Armolite 68580022 Solid Metal Clad Cable Halex 04205B Squeeze Connector
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved.
Halex 05703B Combination Clamp Connector Duraclad 55278322 Type MC Armored Cable Halex 11007B Conduit Elbow
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield, BX, NM or Metal Clad) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. UL Approved. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure.
Halex 04207B Squeeze Connector Armolite 68583422 Solid Metal Clad Cable Halex 04203B Squeeze Connector
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. Fits 1/2" knock outs. UL Approved.
Armolite 68580023 Solid Metal Clad Cable Duraclad 55278323 Type MC Armored Cable Duraclad 55274923 Type MC Armored Cable
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Armolite 68583423 Solid Metal Clad Cable Duraclad 55278301 Type MC Armored Cable Duraclad 55274901 Type MC Armored Cable
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Armorlite 68580001 Type MC Armored Cable Armorlite 68583401 Type MC Armored Cable
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
   
 
1