Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE > BUILDING WIRE / UF
Sort By:
1
Mr Heater 20381 Burner Head LED9MR16DIM027 GU5.3 BIPIN 3K BULB LED R20 45W EQUIV NON-DIM
For use with indoor gaslights. Replaces broken burner head or can be used with soft mantle F220353 and gasket 20339 to convert light from pre-formed mantle to soft mantle. No warm up time, instant-on with full light output and stable color. Mercury and lead free. 3,000K, warm white. 120 volts, 60Hz. cETLus Listed. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
Feit BPMR11/GU10/LED Dimmable LED Lamp Zenith AS110024C Speaker Wire Mr. Heater F220351 Preformed Mantle
Performance LED, for track lighting. 120 volt, 240 lumens, 3000K, 38 degree beam angle, 25,000 average life hours. 1.8" MOL x 1.35" diameter. Instant on to full brightness. Use in dry location only. UL Listed, FCC Compliant, RoHS Compliant. Mercury free. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Replaces broken preformed mantles, or can be used with ceramic burner head 20338 and gasket 20339 to convert light from soft mantle to preformed mantle. Fits Paulin gas lights.
Feit BPMR11/LED Non-Dimmable LED Lamp LED MR16 7W MED E26 DIM 3000K BULB LED GREEN PAR38 REFLECTOR
Performance LED, for track lighting. 12 volt, 240 lumens, 3000K, 38 degree beam angle, 25,000 average life hours. 1.5" MOL x 1.35" diameter. Instant on to full brightness. Suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant. Mercury free. Medium base 7 watt, 120 volt, medium base dimmable Performance LED is a direct replacement for a 50 watt MR16. 520 lumen, 3000K. Average life of 25,000 hours. 42 degree beam spread. Instant on to full brightness, indoor, suitable for damp locations. RoHS and FCC Compliant and mercury free. 2.3"H x 1.5"D. Non-dimmable, indoor/outdoor. Instant on to full brightness. 120 volt, 38 degrees.
LED PAR38 10.5W/75W MED 3000K LED PAR38 MED BS 7W FLOOD YEL Zenith AS105018C Speaker Wire
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Non-dimmable, indoor/outdoor. Instant on to full brightness. 120 volt, 38 degrees. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
BULB LED PAR20 50WATT NON-DIM BULB LED NON-DIMM PAR20 5K 3PK Zenith AS105016C Speaker Wire
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
Romex SIMpull 14/2UF-W/GX25 Building Wire MR16 9W/75W GU10 DIM LED 3000K BULB LIGHT LED MR16 10YR 35W
BULB LED 35W MR16 10YR 3K
Our Price: $15.66
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Performance LED for track lighting. Instant on to full brightness. Suitable for damp locations. Dimmable, average life of 25,000 hours. 100 percent mercury free. 120 volts. UL Listed, FCC Compliant and RoHS Compliant. No warm up time, instant-on with full light output and stable color. Mercury and lead free. 3,000K, warm white. 120 volts, 60Hz. cETLus Listed.
Zenith AS110018C Speaker Wire LED12PAR38 FLOOD E26 3K 1100L Cooper Lighting SNF Narrow Fluorescent Strip Light
Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Ultra LED, directional. Dimmable, E26 medium base. 25,000 hours average life. RoHS compliant, contain no mercury, lead or other hazardous materials and emit no UV or IR radiation. Cooper Lighting Fluorescent Strip Light, Narrow, Series: SNF, 120 V, T8 Lamp, Bi-Pin Lamp Base, 17 W Lamp, 1 Lamps, 2900 lumens, Electronic Ballast, Ceiling Mounting, 2 ft Overall Length, 2-3/4 in Overall Width, Energy Star Certified, UL Listed, For Damp Locations and Residential Applications
BULB LED PAR30L 75WATT NON-DIM Acuity 148TKH Strip Light Zenith AS105014C Speaker Wire
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Provides general illumination for indoor and damp applications. Product features include snap assembly of ends, socket bars and wire way cover. Heavy-duty channel is die formed from 22-gauge steel. Channel cover snaps to housing for access to wire way. Electrical connections are made inside the wire way. Standard mounting holes and wiring knockouts are included. Fixture can be mounted individually or in continuous rows for surface or suspended mounting. Applications include light commercial, industrial, retail, coves and displays. Fluorescent lamps are exposed, no diffuser. Finished in lighting grade white baked gloss enamel paint.  Use with T8 fluorescent linear lamps, not included. cULus listed for damp locations. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
Romex SIMpull 12/2UF-W/GX25 Building Wire BULB LED PAR38 3000K 13W/90W  BULB LED PAR38 5000K 13W/90W
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Medium base, non dimmable, 11000 hours average life. Medium base, non dimmable, 11000 hours average life.
Cooper Lighting SNF Narrow Fluorescent Strip Light Cooper Lighting SNF Narrow Fluorescent Strip Light STRIPLT 1LT LOWPROF T8 120V2FT
Cooper Lighting Fluorescent Strip Light, Narrow, Series: SNF, 120 V, T8 Lamp, Bi-Pin Lamp Base, 32 W Lamp, 1 Lamps, 2900 lumens, Electronic Ballast, Ceiling Mounting, 4 ft Overall Length, 2-3/4 in Overall Width, Energy Star Certified, UL Listed, For Damp Locations and Residential Applications Cooper Lighting Fluorescent Strip Light, Narrow, Series: SNF, 120 V, T8 Lamp, Bi-Pin Lamp Base, 17 W Lamp, 2 Lamps, 2900 lumens, Electronic Ballast, Ceiling Mounting, 2 ft Overall Length, 2-3/4 in Overall Width, Energy Star Certified, UL Listed, For Damp Locations and Residential Applications Compact designed channel and cover are formed from code-gauge cold-rolled steel. Back plate offers compact design and additional socket protection. Locking lamp holder tracks bolster strength of the overall strip construction while creating improved lamp stability. Design includes T8 socket, features rotating collar and enclosed contacts. End plates allow for quick attachment. Designed to accommodate a wide variety of T8 lamp lengths. UL Listed.
Acuity 204RUH Strip Light STRIPLIGHT LOW PROF 1LT T8 4FT STRIP LIGHT T8 2LIGHT 4FT
STRIP LIGHT T8 2LIGHT 4FT
Our Price: $26.09
Provides general illumination for indoor and damp applications. Product features include snap assembly of ends, socket bars and wire way cover. Heavy-duty channel is die formed from 22-gauge steel. Channel cover snaps to housing for access to wire way. Electrical connections are made inside the wire way. Standard mounting holes and wiring knockouts are included. Fixture can be mounted individually or in continuous rows for surface or suspended mounting. Applications include light commercial, industrial, retail, coves and displays. Fluorescent lamps are exposed, no diffuser. Finished in lighting grade white baked gloss enamel paint.  Use with T8 fluorescent linear lamps, not included. cULus listed for damp locations. Compact designed channel and cover are formed from code-gauge cold-rolled steel. Back plate offers compact design and additional socket protection. Locking lamp holder tracks bolster strength of the overall strip construction while creating improved lamp stability. Design includes T8 socket, features rotating collar and enclosed contacts. End plates allow for quick attachment. Designed to accommodate a wide variety of T8 lamp lengths. UL Listed.
Romex SIMpull 14/2UF-WGX50 Building Wire Acuity 204RUG Strip Light Feit PAR38/R/LEDG5 Non-Dimmable LED Lamp
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Provides general illumination for indoor and damp applications. Product features include snap assembly of ends, socket bars and wire way cover. Heavy-duty channel is die formed from 22-gauge steel. Channel cover snaps to housing for access to wire way. Electrical connections are made inside the wire way. Standard mounting holes and wiring knockouts are included. Fixture can be mounted individually or in continuous rows for surface or suspended mounting. Applications include light commercial, industrial, retail, coves and displays. Fluorescent lamps are exposed, no diffuser. Finished in lighting grade white baked gloss enamel paint.  Use with T8 fluorescent linear lamps, not included. cULus listed for damp locations. Non-dimmable, indoor/outdoor. Instant on to full brightness. 120 volt, 38 degrees.
Romex SIMpull 10/2UF-W/GX25 Type UF-B Building Wire Romex SIMpull 12/2UF-WGX50 Building Wire STRIPLIGHT 1LT LOW PROF T8 2FT
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Compact designed channel and cover are formed from code-gauge cold-rolled steel. Back plate offers compact design and additional socket protection. Locking lamp holder tracks bolster strength of the overall strip construction while creating improved lamp stability. Design includes T8 socket, features rotating collar and enclosed contacts. End plates allow for quick attachment. Designed to accommodate a wide variety of T8 lamp lengths. UL Listed.
Romex SIMpull 14/3UF-WGX50 Type UF-B Building Wire Romex SIMpull 14/2UF-WGX100 Building Wire STRIPLIGHT T12 2LAMP 8FT
STRIPLIGHT T12 2LAMP 8FT
Our Price: $41.53
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
STRIP T8 TANDEM 4LAMP 8FT     STRIPLIGHT 2LT GEN PURP T8 4FT STRIPLIGHT 2LAMP T12HO 48IN
STRIP T8 TANDEM 4LAMP 8FT
Our Price: $41.84
Compact designed channel and cover are formed from code-gauge cold-rolled steel. Back plate offers compact design and additional socket protection. Locking lamp holder tracks bolster strength of the overall strip construction while creating improved lamp stability. Design includes T8 socket, features rotating collar and enclosed contacts. End plates allow for quick attachment. Designed to accommodate a wide variety of T8 lamp lengths. UL Listed.
Acuity 211H2M High Output Strip Light Acuity 256441 Tandem Fluorescent Strip STRIP LIGHT SNF T12HO 8FT
STRIP LIGHT SNF T12HO 8FT
Our Price: $52.86
Rugged steel chassis with baked white enamel finishing. Flush, stem or row mounting. Can be hung individually or in continuous runs. 20 degree Fahrenheit starting temperature. 4-1/4" width x 3" depth. Lamps not included. Two 48" fixtures in tandem using two medium bi-pin bulbs each. Flush, stem or row mounting, rugged steel chassis with baked white enamel finish. Uses four 32 watt T-8 lamps, not included. UL Listed for damp locations.
Howard FSR84432ASEMV000I Fluorescent Retro Fit Kit Romex SIMpull 12/2UF-WGX100 Building Wire Romex SIMpull 12/3UF-WGX50 Type UF-B Building Wire
Fluorescent strip channel retrofit kit to upgrade an existing 8? strip fixture into a newer and more efficient electronic T8 strip. Uses two (2) 4? gear trays that install independently for easy installation. Lampholder cutouts guarantee correct spacing and that lampholder will not fall out during install. Code gauge steel. High gloss, baked enamel finish. NEC compliant luminaire power disconnect standard. Contents: 2 gear trays with fully wired high efficiency instant start T8 ballast and lampholders, 12 tek screws, 4 gear tray tethers. Electronic ballast, inherent thermal protection, class P. 8' length, 4.25" width, uses 4 lamps, not included. 120-277 input volts. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Acuity 199YWJ Fluorescent Strip Light Fixture Acuity 111AFH Strip Light Romex SIMpull 14/2UF-W/GX250 Building Wire
White double striplite. Uses two 59 watt bulbs, not included. UL Listed. Fixture can be mounted individually or in continuous rows for surface or suspended mounting. Applications include light commercial, industrial, retail, coves and displays. Heavy-duty channel is die-formed from 22-gauge steel. Channel cover snaps to housing for easy access to wire way. Electrical connections are made inside the wire way. Standard mounting holes and wiring knockouts are included. Housing is finished in lighting grade white baked gloss enamel paint. No diffuser, fluorescent lamp is exposed. For use with 59 watt, 96" T8 slimline linear lamps. The fixture is cULus listed for damp locations. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 12/3UF-WGX100 Type UF-B Building Wire Romex SIMpull 10/2UF-WGX50 Building Wire Romex SIMpull 10/3UF-WGX50 Type UF-B Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Coleman 946016618 Speaker Wire Romex SIMpull 10/2UF-WGX100 Type UF-B Building Wire Romex SIMpull 14/3UF-WGX250 Type UF-B Building Wire
Parallel wire, power limited circuit cable, -20 Celsius to 105 Celsius. Used for stereos and hi-fi systems, home theater sound systems, lamps, and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL Type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 10/3UF-W/GX100 Type UF-B Building Wire Romex SIMpull 12/2UF-W/GX250 Building Wire Coleman 553046607 Type CL-2 Electrical Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved.
Coleman 94605M418 Type CL-2 Speaker Cable Quantum TPE 16/3 SJEOOW 250' SJEOOW Electrical Cord Barostat 553026607 Solid Type CL-2 Thermostat Cable
Parallel wire, power limited circuit cable, -20 Celsius to 105 Celsius. Used for stereos and hi-fi systems, home theater sound systems, lamps, and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL Type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. Provides premium oil resistance, water resistance and flexibility. Use in wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites.  Approved for outdoor use. May be completely immersed in water. Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential. Extra flexible copper conductors. Rated at -60 degree Celsius to 105 degrees. 13 amp - 300 volt - 250' coil.  Meets all applicable requirements of: ASTM, UL 62, and CSA Standard 22.2 No.49. OSHA acceptable. C-UL, UL and MSHA listed. All sizes meet CSA FT-2. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved.
Romex SIMpull 12/3UF-WGX250 Type UF-B Building Wire Coleman 202066603 SJTW Power Cord Barostat 553056607 Solid Type CL-2 Thermostat Cable
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Thermoplastic insulated conductors and jacket. Used for portable tools and lights. Soft annealed stranded copper conductor. Weather resistant PVC jacket. Orange, 250 foot spool. UL62, UL1581 and CSA approved. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved.
Coleman 94607M418 Type CL-2 Speaker Cable Coleman 203066603 SJTW Power Cord Coleman 946036618 Speaker Cable
Parallel wire, power limited circuit cable, -20 Celsius to 105 Celsius. Used for stereos and hi-fi systems, home theater sound systems, lamps, and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL Type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. Thermoplastic insulated conductors and jacket. Used for portable tools and lights. Soft annealed stranded copper conductor. Weather resistant PVC jacket. Orange, 250 foot spool. UL62, UL1581 and CSA approved. Two bare copper conductors laid flat with integral PVC insulation and jacket. Clear jacket construction has one bare copper and one tinned copper conductor. Temperature rated from -20 to 60 degrees C, operating voltage 300 volts maximum. 18/2 stranded, flat, boxed. UL Standard 13 & 444, CSA C22.2 No. 214, NEC Article 725 & 800..
Romex SIMpull 10/2UF-W/GX250 Building Wire Barostat 553036607 Solid Type CL-2 Thermostat Cable Coleman 5407 Bell Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved. Type CL2 low voltage cable using thermoplastic insulated solid conductors. Resistant to the spread of fire in accordance with NEC. Not for riser, plenum, or tray uses and 60 degrees Celsius. Use for thermostat control, burglar alarms, intercoms and doorbells. Soft annealed solid copper per ASTM B3-90 conductor. PVC insulation and UL13 approved for power limited circuit cable for other than plenum, riser, or tray uses. 150 volt.
Coleman 552660408 Low Voltage Cable Coleman 203076603 SJTW Electrical Cable Southwire 65676902 Electrical Wire
Thermoplastic PVC jacketed parallel constructed service cord. Not for hard usage in accordance with NEC. Used for outdoor low voltage lighting systems. Soft annealed stranded cooper per ASTM B3-90 conductor. UL13 approved. Thermoplastic insulated conductors and jacket. Used for portable tools and lights. Soft annealed stranded copper conductor. Weather resistant PVC jacket. Orange, 250 foot spool. UL62, UL1581 and CSA approved. ETL Listed type CL2 power limited circuit cable is a general-purpose 8 conductor low voltage control cable. Construction provides solid uncoated copper conductors insulated with polyvinyl chloride (PVC) insulation twisted together without filler and covered with an ETL listed sunlight resistant PVC jacket. Conductor colors are red, white, green, blue, yellow, brown, orange and black. Used for air conditioning controls, heat pumps, heating controls, thermostats and bell and alarm systems. For use in accordance with the NEC Article 725. Rated 60 degrees Celsius continuous in air. Solid 18/8 type CL2. Meets UL 1581 vertical flame tray test. 15 mil jacket thickness, approximately 202 mil overall cable diameter.
Romex SIMpull 8/2UF-W/GX125 Type UF-B Building Wire Coleman 553076607 Type CL-2 Solid Thermostat Cable Romex SIMpull 10/3UF-WGX250 Type UF-B Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Conductor 18 AWG soft annealed solid copper per ASTM B3-90. PVC thermostatic insulation, temperature 60 degrees Celsius. Used for thermostat controls, heating and air conditioning installations, burglar alarm systems, intercom systems and doorbells. Type CL2, 150 volts. PVC insulation UL13 for power limited circuit cable for other than plenum, riser, or tray uses and UL1581 approved. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Coleman 232860408 SJEW Electrical Cable Coleman 203086603 SJTW Electrical Cord Coleman 2333850408 SJEW Electrical Cable
For hard usage applications in accordance with NEC. Flexible and tough jacket. Temperature range of -50 to 105 degrees C. Used for portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90 conductor. TPE insulation. UL62, UL1581 and CSA-C22.2 No.49 approved. Thermoplastic insulated conductors and jacket. Used for portable tools and lights. Soft annealed stranded copper conductor. Weather resistant PVC jacket. Orange, 250 foot spool. UL62, UL1581 and CSA approved. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved.
Coleman 5408 Bell Wire Romex SIMpull 6/2UF-W/GX125 Type UF-B Building Wire Coleman 233860408 SJEW Electrical Cord
Type CL2 low voltage cable using thermoplastic insulated solid conductors. Resistant to the spread of fire in accordance with NEC. Not for riser, plenum, or tray uses and 60 degrees Celsius. Use for thermostat control, burglar alarms, intercoms and doorbells. Soft annealed solid copper per ASTM B3-90 conductor. PVC insulation and UL13 approved for power limited circuit cable for other than plenum, riser, or tray uses. 150 volt. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Hard service thermoplastic insulated conductors and overall thermoplastic jacket. All elastomer construction. Conductor is soft annealed stranded copper per ASTM B3-90. Temperature range from -50 degrees Celsius to +105 degrees Celsius. For hard usage applications in accordance with NEC and for use with portable tools and lamps, pumps and portable farm equipment. Weather resistant. 300 volt - 250' spool. UL 62, UL1581, CSA-C22.2 No. 49.
Barogation 547070408 Solid Sprinkler Cable Coleman 232870408 SJEW Electrical Cord Coleman 233870408 SJEW Electrical Cable
Underground sprinkler system wire. 18/7 solid, 30 volts RMS max. Used for sprinkler control systems. Soft annealed solid copper per ASTM B3-90. Polyethylene insulation and jacket. 18 AWG bare copper. Cable consists of 7 bare copper insulated conductors with an overall outer jacket diameter of 0.268; UL listed. For hard usage applications in accordance with NEC. Flexible and tough jacket. Temperature range of -50 to 105 degrees C. Used for portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90 conductor. TPE insulation. UL62, UL1581 and CSA-C22.2 No.49 approved. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved.
Coleman 233896608 SJEW Electrical Cable Romex SIMpull 14/2UF-W/GX1000 Type UF-B Building Wire Coleman 233270408 SJEOOW Flexible Power Cord
For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool.
Romex SIMpull 12/2UF-WGX500 Type UF-B Building Wire Romex SIMpull 12/2UF-W/GX1000 Type UF-B Building Wire Coleman 552670508 Low Voltage Cable
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Thermoplastic PVC jacketed parallel constructed service cord. Not for hard usage in accordance with NEC. Used for outdoor low voltage lighting systems. Soft annealed stranded cooper per ASTM B3-90 conductor. UL13 approved.
Coleman 234270408 SJEOW Electrical Cable Coleman 233880408 SJEW Electrical Cable Southwire Stephens Triplex Building Wire
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. Consists of two cross-linked polyethylene insulated phase conductors triplexed with a yellow-striped, cross-linked polyethylene insulated neutral. High quality heat and moisture-resistant cross-linked polyethylene is rated 75 degrees Celsius for wet and 90 degrees Celsius for dry locations. 120 amp maximum in duct or 165 amp in direct earth burial applications with a maximum conductor temperature of 90 degrees Celsius, 600 volt. 2 - 2 - 4 URD x 500' spool. UL Listed.
Coleman 233280408 SJEOOW Electrical Cord Southwire 55039401 Power Supply Cord Coleman 223280408 SEOOW Electrical Wire
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Soft annealed stranded copper. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool.
Southwire 12/2X500 W/G Quartz Single Ended Electrical Wire Coleman 224280408 SEOOW Electrical Wire Coleman 22329M408 SJEOOW Electrical Cable
Pump cable, type THW, thermoplastic (PVC) insulated, 600 volt. All wire insulated. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool.
Coleman 223290408 SEOOW Electrical Wire Southwire 12/3X500 W/G Electrical Wire Romex SIMpull 10/2UF-W/GX1000 Type UF-B Building Wire
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. Pump cable, type THW, thermoplastic (PVC) insulated, 600 volt. All wire insulated. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 6/2UF-W/GX500 Type UF-B Building Wire Southwire Sweetbriar Triplex Building Wire Quantum TPE 55044903 SEOOW Power Cord
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Compact stranded 8000 series aluminum alloy. Cross-linked polyethylene (XLPE) insulation. Multiplexed cable conductors with a left hand lay in a Triplex (3 conductor) assembly. Underground distribution from a supply source to the service entrance equipment of a building. Maximum operating temperature of 90 degrees Celsius in dry and wet locations. 315 amp maximum in direct burial application or 240 amp in ducts. 4/0 - 4/0 - 2/0 x 500' spool, 600 volt. Black color. UL Listed Type USE-2. Wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors, and temporary electrical power and lighting installations for construction sites. 8 gauge, 3 conductor stranded with insulated ground . Rated -50 to 105 degrees C. 40 amp, 600 volt. RoHS Compliant.
Southwire 10/3X500 W/G Twisted Electrical Wire Southwire Monmouth Triplex Building Wire
Pump cable, type THW, thermoplastic (PVC) insulated, 600 volt. All wire insulated. Consists of two cross-linked polyethylene insulated phase conductors triplexed with a yellow-striped, cross-linked polyethylene insulated neutral. High quality heat and moisture-resistant cross-linked polyethylene is rated 75 degrees Celsius for wet and 90 degrees Celsius for dry locations. 240 amp maximum in duct or 315 amp in direct earth burial applications with a maximum conductor temperature of 90 degrees Celsius, 600 volt. 4/0 - 4/0 - 4/0 URD x 500' spool. UL Listed.
   
 
1