Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE > BUILDING WIRE / NM
Sort By:
1
BULB LED BR30 8.5W 2700K      Feit R20/DM/LED Dimmable LED Lamp LED R20 850 DIM 5000K
Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
BULB LED R20 DIM 6W 2700K     Feit BR30/DM/LED Dimmable LED Lamp Feit BR30/DM/5K/LED Dimmable LED Lamp
Ultra LED, directional. Dimmable, medium aluminum base. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free.
Feit BPMR16/GU10/500LE Dimmable LED Lamp BULB LED BR30 DIM 9W 5000K    Feit BPR14DM/LED Dimmable LED Lamp
Performance LED for track lighting. Instant on to full brightness. Suitable for damp locations. Dimmable, average life of 25,000 hours. 100 percent mercury free. 120 volts. UL Listed, FCC Compliant and RoHS Compliant. Medium base, 120 volt, 25,000 hours average life. For track lighting. 120 volts, 2700K, 105 degree beam angle, 25,000 average life hours. Instant on to full brightness.
Feit BPR16DM/LED Dimmable LED Lamp BULB LED BR30 65W EQ DIMMABLE BULB LED BR30 65W EQ DIMMABLE
For track lighting. 120 volts, 2700K, 105 degree beam angle, 25,000 average life hours. Instant on to full brightness. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free.
LED R20 7.5W/45W MED DIM 2700K R20 7.5W/45W MED DIM  LED5000K LED R7S 5W/40W 450LUMENS 3000K
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Non-dimmable R7 base R7S LED. Average life of 15,000 hours, lights up instantly. For accent fixtures and torchiere table or floor lamps. 4.68"H x .875" D. UL/CUL Listed, FCC and RoHS Compliant, mercury free.
LED7.5BR30DIM 7.5/65W EQV 5K  BULB LED 10YR 65W BR30 27K 2PK BULB LIGHT LED 10YR BR30 60W
Medium base, 120 volt, 25,000 hours average life. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant.
BULB LED BR30 10YR DIM35K 65W Feit 17BR40/DM/LED Dimmable LED Lamp BULB LED BR40 DIM 12W 2700K
Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. For track lighting. Instant on to full brightness. Suitable for damp locations. 25,000 average life hours. 120 volt, 110 degree beam spread. FCC Compliant. 100 percent mercury free. Medium base, 120 volt, 25,000 hours average life.
LED BR40 927 15.5W DIM 2700K  LED9MR16DIM027 GU5.3 BIPIN 3K BULB LED R20 10YR DIM 27K 50W
For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. No warm up time, instant-on with full light output and stable color. Mercury and lead free. 3,000K, warm white. 120 volts, 60Hz. cETLus Listed. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant.
BULB LED R20 10YR DIM 5K 50W  BULB LED R20 10YR DIM 35K 50W BULB LED BR40 DIM 12W 5000K
Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Medium base, 120 volt, 25,000 hours average life.
BULB LED BR40 DIM 12W 3500K   BULB LED 65W BR30 E26 27K 650L Feit BPMR11/GU10/LED Dimmable LED Lamp
Medium base, 120 volt, 25,000 hours average life. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Performance LED, for track lighting. 120 volt, 240 lumens, 3000K, 38 degree beam angle, 25,000 average life hours. 1.8" MOL x 1.35" diameter. Instant on to full brightness. Use in dry location only. UL Listed, FCC Compliant, RoHS Compliant. Mercury free.
LED R7S 8W/60W 800LUMENS 3000K LED MR16 7W MED E26 DIM 3000K BULB LED INTGRTD 27K 15W/65W
Non-dimmable R7 base R7S LED. Average life of 15,000 hours, lights up instantly. For accent fixtures and torchiere table or floor lamps. 4.68"H x .875" D. UL/CUL Listed, FCC and RoHS Compliant, mercury free. Medium base 7 watt, 120 volt, medium base dimmable Performance LED is a direct replacement for a 50 watt MR16. 520 lumen, 3000K. Average life of 25,000 hours. 42 degree beam spread. Instant on to full brightness, indoor, suitable for damp locations. RoHS and FCC Compliant and mercury free. 2.3"H x 1.5"D. Dimmable, 11,000 average life hours. E26 medium base.
Romex SIMpull 14/2NM-WGX25 Building Wire LED BR40 10.5W/65W MED DIM 5K MR16 9W/75W GU10 DIM LED 3000K
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. Performance LED for track lighting. Instant on to full brightness. Suitable for damp locations. Dimmable, average life of 25,000 hours. 100 percent mercury free. 120 volts. UL Listed, FCC Compliant and RoHS Compliant.
BULB LED BR40 DIMMABLE 5000K  BULB LED BR40 DIMMABLE 2700K  BULB LIGHT LED MR16 10YR 35W
BULB LED 35W MR16 10YR 3K
Our Price: $15.66
For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. No warm up time, instant-on with full light output and stable color. Mercury and lead free. 3,000K, warm white. 120 volts, 60Hz. cETLus Listed.
BULB LED BR40 HO35K 11K-HR 85W BULB LED BR40 HO5K 13/85W     BULB LED BR30 65W DIMMABLE
Medium base, non dimmable, 11000 hours average life. Medium base, non dimmable, 11000 hours average life. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free.
Romex SIMpull 12/2NM-WGX25 Building Wire BULB LED BR40 DIM 27K 13W/85W BULB LED BR40 DIM 5K 13W/85W
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant.
Romex SIMpull 14/3NM-WGX25 Building Wire Feit BR40/DM/2500/3K/L Dimmable LED Lamp Romex SIMpull 14/2NM-WGX50 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. For track lighting. Instant on to full brightness. Suitable for damp locations. 25,000 average life hours. 120 volt, 110 degree beam spread. FCC Compliant. 100 percent mercury free. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/3NM-WGX25 Building Wire Romex SIMpull 14/2NM-WGX100 Building Wire Romex SIMpull 10/2NM-WGX25 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/2NM-WGX50 Building Wire Romex SIMpull 14/3NM-WGX50 Building Wire Romex SIMpull 10/3NM-WGX25 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 14/2NM-WGX250 Building Wire Romex SIMpull 12/2NM-WGX100 Building Wire WIRE BUILDING 8/3NM-B W/G 25FT
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C.
Romex SIMpull 12/3NM-WGX50 Building Wire Romex SIMpull 10/2NM-WGX50 Building Wire Romex SIMpull 14/3NM-WGX100 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/2NM-WGX250 Building Wire WIRE BUILDING 6/3NM-B W/G 25FT Romex SIMpull 14/3NM-WGX250 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 10/3NM-WGX50 Building Wire Romex SIMpull 12/3NM-WGX100 Type NM-B Building Wire Romex SIMpull 10/2NM-WGX100 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
WIRE BUILDING 8/3NM-B W/G 50FT Coleman 600006621 SPT-1 Lamp Cord Coleman 600006619 SPT-1 Lamp Cord
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 600006607 SPT-1 Lamp Cord Coleman 600006608 SPT-1 Lamp Cord Coleman 600006618 SPT-1 Lamp Cord
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 600006601 SPT-1 Lamp Cord Romex SIMpull 8/2NM-WGX125 Type NM-B Building Wire Romex SIMpull 10/3NM-WGX100 Type NM-B Building Wire
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/3NM-WGX250 Type NM-B Building Wire Romex SIMpull 28827472 Type NM-B Building Wire Romex SIMpull 10/2NM-WGX250 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Quantum TPE 16/3 SJEOOW 250' SJEOOW Electrical Cord Coleman 601266607 SPT-2 Lamp Cord Coleman 601266608 SPT-2 Lamp Cord
Provides premium oil resistance, water resistance and flexibility. Use in wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites.  Approved for outdoor use. May be completely immersed in water. Ideal for flex applications in harsh environments where the highest degree of oil resistance and extended service life are essential. Extra flexible copper conductors. Rated at -60 degree Celsius to 105 degrees. 13 amp - 300 volt - 250' coil.  Meets all applicable requirements of: ASTM, UL 62, and CSA Standard 22.2 No.49. OSHA acceptable. C-UL, UL and MSHA listed. All sizes meet CSA FT-2. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool.
Coleman 601266601 SPT-2 Lamp Cord WIRE BUILDING 6/3NM-B W/G 50FT Coleman 202066603 SJTW Power Cord
Thermoplastic PVC jacket, not for hard usage in accordance with NEC. Used for lamps, small appliances and radios. Soft annealed stranded copper per ASTM B3-90 conductor. 300 volt maximum. PVC insulation and UL62, UL1581 Listed. Spool. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Thermoplastic insulated conductors and jacket. Used for portable tools and lights. Soft annealed stranded copper conductor. Weather resistant PVC jacket. Orange, 250 foot spool. UL62, UL1581 and CSA approved.
Romex SIMpull 6/2NM-WGX125 Type NM-B Building Wire Coleman 203066603 SJTW Power Cord Romex SIMpull 8/3NM-WGX125 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Thermoplastic insulated conductors and jacket. Used for portable tools and lights. Soft annealed stranded copper conductor. Weather resistant PVC jacket. Orange, 250 foot spool. UL62, UL1581 and CSA approved. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 28828272 Type NM-B Building Wire Romex SIMpull 14/2NM-WGX1000 Type NM-B Building Wire Romex SIMpull 63946872 Type NM-B Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 12/2NMW/GX500FT Type NM-B Building Wire Romex SIMpull 63947672 Type NM-B Building Wire Coleman 203076603 SJTW Electrical Cable
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Thermoplastic insulated conductors and jacket. Used for portable tools and lights. Soft annealed stranded copper conductor. Weather resistant PVC jacket. Orange, 250 foot spool. UL62, UL1581 and CSA approved.
Southwire 6SOLX315BARE Solid Electrical Wire Southwire 8SOLX500BARE Solid Electrical Wire Southwire 6STRDX315BARE Stranded Electrical Wire
Equipment and circuit grounding. Equipment and circuit grounding. Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems.
Southwire 4STRDX200BARE Stranded Electrical Wire Southwire 4SOLX200BARE Solid Electrical Wire Romex SIMpull 10/3NM-WGX250 Type NM-B Building Wire
Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems. Equipment and circuit grounding. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Southwire 2SOLX125BARE Solid Electrical Wire Romex SIMpull 63949272 Type NM Building Wire Southwire 10SOLX800BARE Linear Electrical Wire
Equipment and circuit grounding. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Equipment and circuit grounding.
Romex SIMpull 63948472 Type NM-B Building Wire Romex SIMpull 6/3NM-WGX125 Type NM-B Building Wire Coleman 232860408 SJEW Electrical Cable
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. For hard usage applications in accordance with NEC. Flexible and tough jacket. Temperature range of -50 to 105 degrees C. Used for portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90 conductor. TPE insulation. UL62, UL1581 and CSA-C22.2 No.49 approved.
Coleman 203086603 SJTW Electrical Cord Coleman 2333850408 SJEW Electrical Cable Romex SIMpull 12/2NM-WGX1000 Type NM-B Building Wire
Thermoplastic insulated conductors and jacket. Used for portable tools and lights. Soft annealed stranded copper conductor. Weather resistant PVC jacket. Orange, 250 foot spool. UL62, UL1581 and CSA approved. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 28829072 Type NM-B Building Wire Romex SIMpull 63950072 Type NM-B Building Wire Coleman 233860408 SJEW Electrical Cord
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Hard service thermoplastic insulated conductors and overall thermoplastic jacket. All elastomer construction. Conductor is soft annealed stranded copper per ASTM B3-90. Temperature range from -50 degrees Celsius to +105 degrees Celsius. For hard usage applications in accordance with NEC and for use with portable tools and lamps, pumps and portable farm equipment. Weather resistant. 300 volt - 250' spool. UL 62, UL1581, CSA-C22.2 No. 49.
Coleman 232870408 SJEW Electrical Cord Coleman 233870408 SJEW Electrical Cable Coleman 233896608 SJEW Electrical Cable
For hard usage applications in accordance with NEC. Flexible and tough jacket. Temperature range of -50 to 105 degrees C. Used for portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90 conductor. TPE insulation. UL62, UL1581 and CSA-C22.2 No.49 approved. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved.
Coleman 233270408 SJEOOW Flexible Power Cord Romex SIMpull 8/2NM/WG 500 FT Type NM-B Building Wire Romex SIMpull 14/3NM-WGX1000FT Type NM-B Building Wire
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 12/3NM-WGX1000FT Type NM-B Building Wire Coleman 233280408 SJEOOW Electrical Cord Coleman 234270408 SJEOW Electrical Cable
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool.
Coleman 233880408 SJEW Electrical Cable Romex SIMpull 10/2NM-WGX1000 Type NM-B Building Wire Southwire 55039401 Power Supply Cord
For hard usage applications in accordance with NEC. Used with portable tools and lamps, pumps, portable farm equipment. Soft annealed stranded copper per ASTM B3-90. Black TPE insulation and jacket. UL62, UL1581, CSA approved. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Soft annealed stranded copper. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool.
Romex SIMpull 6/2NM-WGX500 Type NM-B Building Wire Coleman 223280408 SEOOW Electrical Wire Romex SIMpull 8/3NM-W/GX500 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 10/3NM-WGX1000FT Type NM-B Building Wire Coleman 224280408 SEOOW Electrical Wire Coleman 22329M408 SJEOOW Electrical Cable
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool.
Coleman 223290408 SEOOW Electrical Wire Romex SIMpull 6/3NM-W/GX500 Type NM-B Building Wire Quantum TPE 55044903 SEOOW Power Cord
Extra hard usage per NEC. Used for garages, portable tools and lights, battery chargers. Weather resistant for outdoor applications, dishwashers and refrigerators. Resists most acids 10 AWG through 14 AWG, 60 degrees Celsius to 105 degrees Celsius. Soft annealed stranded copper per ASTM B3-90 conductor. TPE class 36, rubber insulation. TPE weather resistant class 36, black rubber jacket. UL 62, UL1581, CSA approved. Black, 250' spool. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Wiring for industrial machinery, washing machines and various other large appliances, heavy-duty tools, motors, and temporary electrical power and lighting installations for construction sites. 8 gauge, 3 conductor stranded with insulated ground . Rated -50 to 105 degrees C. 40 amp, 600 volt. RoHS Compliant.
   
 
1