Home > ELECTRICAL > ROUGH ELECTRICAL > ELECTRICAL WIRE
Choose a sub category:
BUILDING WIRE / NM BUILDING WIRE / THHN BUILDING WIRE / UF
ENTRANCE CABLE ARMORED CABLE GROUND WIRE
LAMP CORD SJ CORD SPECIALTY WIRE
Sort By:
1
LED PAR20 7W/50W MED DIM 3000K Fulcrum Light-It Stick-on-Light Fulcrum 30015-303 Light-It Versatile Tap Light
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Fulcrum Stick-on-Light, Energy Efficient, Series: Light-It, LED Bulb, Flood Beam, 13.5 lumens, 100 hr Average Life, Alkaline Battery, AAA Battery, 3 Batteries, ABS Plastic Body, Silver Body, 2-1/2 in Diameter, 1/2 in Overall Height, Includes: (3) AAA Batteries, For Illuminating Dark Storage Areas and Workspaces Fulcrum Tap Light, Versatile, Series: Light-It, LED Bulb, 9 Bulbs, Flood Beam, 40.5 lumens, 100000 hr Average Life, Alkaline Battery, AAA Battery, 3 Batteries, Black Body, Includes: (3) AAA Batteries, For Any Dark Space, Closets, Cabinets, Boats, Rvs and More
Fulcrum 30015-308 Light-It Versatile Tap Light LIGHT STICK ON BRONZE 3PACK   LIGHT STICK ON WHITE 3PACK
Fulcrum Tap Light, Versatile, Series: Light-It, LED Bulb, 9 Bulbs, Flood Beam, 40.5 lumens, 100000 hr Average Life, Alkaline Battery, AAA Battery, 3 Batteries, White Body, Includes: (3) AAA Batteries, For Any Dark Space, Closets, Cabinets, Boats, Rvs and More Mounts anywhere, adhesive backing. 13.5 lumens. Tapping the center of the light turns it on/off. Uses 3 AAA batteries (not included). Mounts anywhere, adhesive backing. 13.5 lumens. Tapping the center of the light turns it on/off. Uses 3 AAA batteries (not included).
Rite Lite LPL620W Wireless Puck Light BULB LED BR30 65W EQUIV NONDIM LED BR30 8.5W/65W MED BS 2700K
On/off/dimmer operation. Press once for full brightness. Press again for softer light. Press a third time to turn the light off. Light head swivels 360 degrees and pivots 30 degrees for optimal light positioning. Mounts with hook and loop tape or screw mount bracket. Uses 3 AAA batteries. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free.
BULB LED PAR20 DIM 7W 3000K   Feit G4/LED Non-Dimmable LED Lamp Feit G8/LED Non-Dimmable LED Lamp
Ultra LED, directional. Dimmable, medium aluminum base. Performance LED, 20 watt replacement, has an average life of 15,000 hours and is mercury free. 3000K, 160 lumens. Energy saving, non-dimmable. Performance LED, 20 watt replacement, has an average life of 15,000 hours and is mercury free. 3000K, 160 lumens. Energy saving, non-dimmable.
LED GY6.35 BASE 2.5W/20W 3000K LED GY8.6 BASE 2.5W/20W 3000K WEDGE BASE 2W/20W 12V LED3000K
Non-dimmable LED, 2.5 watt, 120 volt, 3000K. Performance LED is a 20 watt replacement, has an average life of 15,000 hours. Instant on to full brightness, suitable for damp locations. ETL/CUL Listed, FCC and RoHS Compliant and mercury free. 1.75"H x 0.75"D. Non-dimmable LED, 2.5 watt, 120 volt, 3000K. Performance LED is a 20 watt replacement, has an average life of 15,000 hours. Instant on to full brightness, suitable for damp locations. ETL/CUL Listed, FCC and RoHS Compliant and mercury free. 1.75"H x 0.75"D. Non-dimmable LED, 2 watt, 12 volt wedge base. 160 lumens, 3000K. Performance LED, 20 watt replacement. Average life of 15,000 hours. Instant on to full brightness. Suitable for damp locations. FCC and RoHS Compliant, mercury free. 1.9"h x .60"D.
LED PAR30L 930 13W DIM 3000K  LED 7W PAR20 5000K MED BS FLD Southwire 55082415 Armored Cable
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Ultra LED, directional. Dimmable, medium aluminum base. Wire whip, 14/3 AWG.
Fulcrum 20042-301 Under Cabinet Light Zenith AS110024C Speaker Wire LED PAR38 G10 MED 3000K
Fulcrum Under Cabinet Light, LED Lamp, 6 Lamps, Battery Operated Power, Bright Light, Silver, 6 in Length, For Counters, Work Areas and Book Shelves Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
BULB LED PAR38 75WEQUIV NONDIM Zenith AS105018C Speaker Wire LED5PAR16 DIM GU10 BASE 3000K
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. No warm up time, instant-on with full light output and stable color. Mercury and lead free. 3,000K, warm white. 120 volts, 60Hz. cETLus Listed.
LED5.5PAR20 DIM E26 3000K 400L Zenith AS105016C Speaker Wire PAR20 7W/50W MED DIM LED 5000K
Ultra LED, directional. Dimmable, medium aluminum base. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
Romex SIMpull 14/2NM-WGX25 Building Wire Romex SIMpull 14/2UF-W/GX25 Building Wire LIGHT MOTION LOW PROFILE
LIGHT MOTION LOW PROFILE
Our Price: $14.07
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. For under a cabinet, over a workspace or in a closet. White light through a 3 sided lens that distributes light all around and also has a dim mode for low light needs.
BAR LIGHT LED ON/OFF          PAR38 20W COLD START LED 3000K BAR CLAMP SWIVEL REMOTE CNTROL
BAR LIGHT LED ON/OFF
Our Price: $14.28
Slim profile design. 100 lumens of warm white light. Uses 3 AA batteries (not included) and has a run time of 25 hours. Includes double sided tape and magnets for mounting. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. For under a cabinet, over a workspace or in a closet. White light through a 3 sided lens that distributes light all around and also has a dim mode for low light needs.
LIGHT UND-CAB W/IR LED REMOTE LIGHT 20 LED ANYWHERE         Zenith AS110018C Speaker Wire
Illuminate recreational areas and work spaces with the low profile LED bar light. Included screws and double-sided tape. Use remote to turn on/off/dim or set an auto-off timer or allow the photocell to automatically turn the light on when needed. Remote works up to 20 feet away and includes an auto-off timer for 15, 30, 60 or 120 minutes. Warm white light (3000K), 95 lumens, requires 6 AA batteries (not included). Anywhere light, 20-LED, portable, 80 lumens. Uses 4 AAA batteries (not included). For spaces that need extra-strong light. It fastens easily onto the wall or under a cabinet with tape or screws (included). Reliable, energy-efficient LEDs make it a good choice for power outages and emergencies. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
Fulcrum 30016-308 Light-It Versatile Tap Light LIGHT 9 LED XB ANYWHERE BLACK LIGHT 9 LED XB ANYWHERE BRONZE
Fulcrum Tap Light, Versatile, Series: Light-It, LED Bulb, 9 Bulbs, Flood Beam, 40.5 lumens, 100000 hr Average Life, Alkaline Battery, AAA Battery, 3 Batteries, White Body, Includes: (3) AAA Batteries, For Any Dark Space, Closets, Cabinets, Boats, Rvs and More Versatile, extra bright. 40.5 lumens. Included adhesive strips and integral mounting bracket. Once installed, the light can be detached from the bracket for handheld use. Uses 3 AAA batteries (not included). Versatile, extra bright. 40.5 lumens. Included adhesive strips and integral mounting bracket. Once installed, the light can be detached from the bracket for handheld use. Uses 3 AAA batteries (not included).
Armorlite 68580021 Type MC Armored Cable Armorlite 68579221 Type MC Armored Cable PAR30L 10.5W 830 DIM LED 3000K
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
PAR30L 10.5W 850 DIM LED 5000K LIGHT PUCK LED W/REMOTE       Cooper Lighting SNF Narrow Fluorescent Strip Light
LIGHT PUCK LED W/REMOTE
Our Price: $17.58
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Slim, wireless with 30 degrees pivot and 360 degree rotation. Add directional accent light in cabinet displays, closets, pantries, offices, workshops, and more. Can be operated by a simple push of the light head, once for full brightness and twice to turn off. Included IR remote features a 15, 30, 60, or 120 minute auto-off timer. 55 lumens per puck. Warm white light (3000K). Runs on 3 AAA batteries (not included). 3.5" L x 3.5" W x 1.25" H. Cooper Lighting Fluorescent Strip Light, Narrow, Series: SNF, 120 V, T8 Lamp, Bi-Pin Lamp Base, 17 W Lamp, 1 Lamps, 2900 lumens, Electronic Ballast, Ceiling Mounting, 2 ft Overall Length, 2-3/4 in Overall Width, Energy Star Certified, UL Listed, For Damp Locations and Residential Applications
LIGHT PUCK RC LED             Romex SIMpull 12/2NM-WGX25 Building Wire Good Earth Lighting GLS9721-GROW-WH Under Cabinet Light Fixtures
LIGHT PUCK RC LED
Our Price: $18.19
Slim profile design. 45 lumens of glare-free, diffused light with a dim mode for low light needs. Remote auto off timer with settings for 15, 30, 60 or 120 minutes. Double sided tape and screws included. Powered by 3 AAA batteries (not included) and has a run time of 18 hours. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. White finish under counter grow light with on/off switch. 22" long x 1.875" deep x 2.25" high. Non-metallic case. Plug in only. Uses one F15T8 linear fluorescent bulb, included.
Romex SIMpull 14/3NM-WGX25 Building Wire Duraclad 55278321 Type MC Armored Cable Zenith AS105014C Speaker Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Used for stereos and hi-fi systems, home theater sound systems. Connects speaker to receiver, tuner/amplifier.
Duraclad 55274921 Type MC Armored Cable Romex SIMpull 12/2UF-W/GX25 Building Wire LAMP LED SILVER WIRELESS
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Plastic, 60 lumens. Lightweight, durable and portable. Touching a finger to the top of the light turns it on and off. 3 "C" batteries (not included).
LAMP LED BRONZE WIRELESS      LAMP LED WHITE WIRELESS       BAR W/RF LED REMOTE DIMMER TMR
Plastic, 60 lumens. Lightweight, durable and portable. Touching a finger to the top of the light turns it on and off. 3 "C" batteries (not included). Plastic, 60 lumens. Lightweight, durable and portable. Touching a finger to the top of the light turns it on and off. 3 "C" batteries (not included). Slim profile design. 100 lumens of warm white light. Uses 3 AA batteries (not included) and has a run time of 25 hours. Includes double sided tape and magnets for mounting.
BAR LED MOTION SENSOR MNUL    LIGHT PUCK LD OPT SNSR GRY 3PK LIGHT 10 LED SENSOR ANYWHERE
Slim profile design. 100 lumens of warm white light. Uses 3 AA batteries (not included) and has a run time of 25 hours. Includes double sided tape and magnets for mounting. One-touch on/dim/off with ambient light sensor. Head pivots 30 degrees and swivels 360 degrees. Installs with the included screw or hooks and loop tape. Each light takes 3 AAA batteries (not included). 3.25" L x 3.25" W x 2.25" H. Portable, mounting bracket, motion or on/off. 65 lumens, 3 AA batteries (not included). Comes with an adhesive strip and optional angled mounting bracket enabling it to be installed anywhere. It features an optional motion sensor, and detaches from its bracket for hand-held use. Broad beam of light.
Romex SIMpull 14/2NM-WGX50 Building Wire Cooper Lighting SNF Narrow Fluorescent Strip Light LIGHT UNDER CABINET
LIGHT UNDER CABINET
Our Price: $22.95
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Cooper Lighting Fluorescent Strip Light, Narrow, Series: SNF, 120 V, T8 Lamp, Bi-Pin Lamp Base, 32 W Lamp, 1 Lamps, 2900 lumens, Electronic Ballast, Ceiling Mounting, 4 ft Overall Length, 2-3/4 in Overall Width, Energy Star Certified, UL Listed, For Damp Locations and Residential Applications Turn on/off with a wave of a hand. Flood an area with light or soft illumination. Adhesive magnetic mount detaches from the bracket for handheld use and battery replacement. Infrared motion sensor switch. Two brightness modes, 100 lumens maximum. Ultra-slim 0.8" profile. LEDs last 100,000 hours. Uses 3 AA batteries, (not included). Double-stick tape, screws and drywall anchors included. 0.7 lb., 19"L x 1"D x 6"W.
Southwire 22955952 THHN Building Wire Southwire 22957552 THHN Building Wire Southwire 22956752 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22959152 THHN Building Wire Cooper Lighting SNF Narrow Fluorescent Strip Light LAMP LED LUX WIRELESS
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Cooper Lighting Fluorescent Strip Light, Narrow, Series: SNF, 120 V, T8 Lamp, Bi-Pin Lamp Base, 17 W Lamp, 2 Lamps, 2900 lumens, Electronic Ballast, Ceiling Mounting, 2 ft Overall Length, 2-3/4 in Overall Width, Energy Star Certified, UL Listed, For Damp Locations and Residential Applications Touch top operation. 100 lumens, 3 AA batteries (not included). Operates on a touch-activated, three-stage dimmer for varying levels of brightness.
Southwire 22955951 THHN Building Wire Southwire 22956751 THHN Building Wire Southwire 22957551 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22959151 THHN Building Wire Southwire 22973236 THHN Building Wire Southwire 22974036 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22975736 THHN Building Wire Southwire 22977336 THHN Building Wire STRIPLT 1LT LOWPROF T8 120V2FT
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Compact designed channel and cover are formed from code-gauge cold-rolled steel. Back plate offers compact design and additional socket protection. Locking lamp holder tracks bolster strength of the overall strip construction while creating improved lamp stability. Design includes T8 socket, features rotating collar and enclosed contacts. End plates allow for quick attachment. Designed to accommodate a wide variety of T8 lamp lengths. UL Listed.
Acuity 204RUH Strip Light STRIP LIGHT T8 2LIGHT 4FT     Romex SIMpull 14/2UF-WGX50 Building Wire
STRIP LIGHT T8 2LIGHT 4FT
Our Price: $26.09
Provides general illumination for indoor and damp applications. Product features include snap assembly of ends, socket bars and wire way cover. Heavy-duty channel is die formed from 22-gauge steel. Channel cover snaps to housing for access to wire way. Electrical connections are made inside the wire way. Standard mounting holes and wiring knockouts are included. Fixture can be mounted individually or in continuous rows for surface or suspended mounting. Applications include light commercial, industrial, retail, coves and displays. Fluorescent lamps are exposed, no diffuser. Finished in lighting grade white baked gloss enamel paint.  Use with T8 fluorescent linear lamps, not included. cULus listed for damp locations. Wide strip light. 120 volt electronic ballast. Uses varousT8 lamp types (sold separately). Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Cooper Lighting SNF Narrow Fluorescent Strip Light Armorlite 68579222 Type MC Armored Cable LIGHT TRACK LED UC AC/BATT WHT
Cooper Lighting Fluorescent Strip Light, Narrow, Series: SNF, 120 V, T8 Lamp, Bi-Pin Lamp Base, 32 W Lamp, 2 Lamps, 2800 lumens, Electronic Ballast, Ceiling Mounting, 4 ft Overall Length, 2-3/4 in Overall Width, Energy Star Certified, UL Listed, For Damp Locations and Residential Applications Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Base with four independently swiveling, pivoting light heads with super-bright white LEDs. Choose from three power settings: on, dim, or off with a push button. Installation with the included hook and loop tape or mounting bracket. Runs on 6 AAA batteries (not included).
Armorlite 68583421 Type MC Armored Cable Southwire 22966652 THHN Building Wire Southwire 22964152 THHN Building Wire
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22968252 THHN Building Wire Southwire 22965852 THHN Building Wire Duraclad 55274922 Type MC Armored Cable
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Duraclad 55278521 Type MC Armored Cable SIMpull 22964151 THHN Building Wire SIMpull 22965851 THHN Building Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
SIMpull 22966651 THHN Building Wire SIMpull 22968251 THHN Building Wire Duraclad 55275021 Type MC Armored Cable
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Romex SIMpull 10/2NM-WGX25 Building Wire Armolite 68580022 Solid Metal Clad Cable LIGHT UTILITY NIGHT LED WHITE
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Can be mounted anywhere light is needed. Includes hook and loop squares and double-faced tape for mounting. Tap on/off LED. Uses 3 AAA batteries (included). 2.75" L x 2.75" W x 1" H.
Romex SIMpull 12/3NM-WGX25 Building Wire Romex SIMpull 14/2NM-WGX100 Building Wire Romex SIMpull 12/2NM-WGX50 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
LIGHTS BAR MINI TASK          BAR EVERYWHERE                Romex SIMpull 14/3NM-WGX50 Building Wire
LIGHTS BAR MINI TASK
Our Price: $34.35
BAR EVERYWHERE
Our Price: $34.80
Small, slim design. Lasts up to 15 hours on a single set of batteries. Simple on/off operation. Portable or mount to wall. Cool to the touch LEDs. Warm white light (3000K). 70 lumens. Requires 3 AAA batteries (not included). 7" L x 1.75" W x 1" D. For under a cabinet, over a workspace or in a closet. White light through a 3 sided lens that distributes light all around and also has a dim mode for low light needs. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Duraclad 55278322 Type MC Armored Cable Romex SIMpull 12/2UF-WGX50 Building Wire Romex SIMpull 10/2UF-W/GX25 Type UF-B Building Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
LIGHT PUCK LED W/SENSOR GREY  Southwire 16BLK-STRX500 Building Wire Southwire 22973237 THHN Building Wire
On/off/dimmer operation. Press once for full brightness. Press again for softer light. Press a third time to turn the light off. Light head swivels 360 degrees and pivots 30 degrees for optimal light positioning. Mounts with hook and loop tape or screw mount bracket. Uses 3 AAA batteries. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22977337 THHN Building Wire Southwire 22974037 THHN Building Wire Southwire 22975737 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
STRIPLIGHT 1LT LOW PROF T8 2FT LIGHT PUCK UTILITY SILVER     Romex SIMpull 14/3UF-WGX50 Type UF-B Building Wire
LIGHT PUCK UTILITY SILVER
Our Price: $39.17
Compact designed channel and cover are formed from code-gauge cold-rolled steel. Back plate offers compact design and additional socket protection. Locking lamp holder tracks bolster strength of the overall strip construction while creating improved lamp stability. Design includes T8 socket, features rotating collar and enclosed contacts. End plates allow for quick attachment. Designed to accommodate a wide variety of T8 lamp lengths. UL Listed. Can be mounted anywhere light is needed. Includes hook and loop squares and double-faced tape for mounting. Tap on/off LED. Uses 3 AAA batteries (included). 2.75" L x 2.75" W x 1" H. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 14/2UF-WGX100 Building Wire Southwire 14BK-SOLX500 Solid Single Building Wire Southwire 14WHT-SOLX500 Solid Single Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 14RED-SOLX500 Solid Single Building Wire Southwire 14GRN-SOLX500 Solid Single Building Wire Southwire 14BLUE-SOLX500 Solid Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 14YEL-SOLX500 Building Wire STRIPLIGHT T12 2LAMP 8FT      STRIP T8 TANDEM 4LAMP 8FT
STRIPLIGHT T12 2LAMP 8FT
Our Price: $41.53
STRIP T8 TANDEM 4LAMP 8FT
Our Price: $41.84
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Wide strip light. 120 volt electronic ballast. Uses varousT12/75w, 120 volt lamp types (sold separately). Wide 8 ft. 4-lamp tandem standard strip. T8/32W, 120/277V commercial ballast. Uses various T12 or T8 lamp types (sold separately).
FIXTURE LED 19W 2X2FT GROW LT LIGHT PUCK UTILITY BLACK 3PK  BAR CLAMP SWIVEL
BAR CLAMP SWIVEL
Our Price: $45.76
Fully assembled, dual 2ft LED grow light requires no lamps to replace. Rated for high humidity use. Instant full brightness. No humming. Includes 5 foot plug-in cord with on/off rocker switch and a 6 inch hanging wire harness. Linkable up to 8 fixtures. UL/CUL Listed FCC Compliant. 1.73"H x 23.3"L. 120 volt, 19 watts. Can be mounted anywhere light is needed. Includes hook and loop squares and double-faced tape for mounting. Tap on/off LED. Uses 3 AAA batteries (included). 2.75" L x 2.75" W x 1" H. For under a cabinet, over a workspace or in a closet. White light through a 3 sided lens that distributes light all around and also has a dim mode for low light needs.
STRIPLIGHT 2LAMP T12HO 48IN   Romex SIMpull 14/2NM-WGX250 Building Wire Armolite 68583422 Solid Metal Clad Cable
Wide 4 ft. 2-lamp HO wide strip. T120HO/48W, 120V residential ballast. Uses various T12 or T8 lamp types (sold separately). Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Romex SIMpull 10/3NM-WGX25 Building Wire STRIP LIGHT 2LAMP T5HO 4FT    Acuity 211H2M High Output Strip Light
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Rugged steel chassis with baked white enamel finishing. Flush, stem or row mounting. Can be hung individually or in continuous runs. 20 degree Fahrenheit starting temperature. 4-1/4" width x 3" depth. Lamps not included.
Southwire 14BK-STRX500 Stranded Single Building Wire Southwire 14GRN-STRX500 Stranded Single Building Wire Southwire 14WHT-STRX500 Stranded Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed.
Southwire 14RED-STRX500 Stranded Single Building Wire Southwire 14BLUE-STRX500 Stranded Single Building Wire Romex SIMpull 12/2NM-WGX100 Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
STRIP LIGHT SNF T12HO 8FT     LIGHT BALL MOTION 150L        Armolite 68580023 Solid Metal Clad Cable
STRIP LIGHT SNF T12HO 8FT
Our Price: $52.86
LIGHT BALL MOTION 150L
Our Price: $54.12
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
WIRE BUILDING 8/3NM-B W/G 25FT Romex SIMpull 12/3NM-WGX50 Building Wire Duraclad 55278323 Type MC Armored Cable
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Duraclad 55274923 Type MC Armored Cable Howard FSR84432ASEMV000I Fluorescent Retro Fit Kit Romex SIMpull 12/3UF-WGX50 Type UF-B Building Wire
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Fluorescent strip channel retrofit kit to upgrade an existing 8? strip fixture into a newer and more efficient electronic T8 strip. Uses two (2) 4? gear trays that install independently for easy installation. Lampholder cutouts guarantee correct spacing and that lampholder will not fall out during install. Code gauge steel. High gloss, baked enamel finish. NEC compliant luminaire power disconnect standard. Contents: 2 gear trays with fully wired high efficiency instant start T8 ballast and lampholders, 12 tek screws, 4 gear tray tethers. Electronic ballast, inherent thermal protection, class P. 8' length, 4.25" width, uses 4 lamps, not included. 120-277 input volts. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Acuity 199YWJ Fluorescent Strip Light Fixture Romex SIMpull 14/3NM-WGX100 Building Wire Southwire 12YEL-SOLX500 Solid Single Building Wire
White double striplite. Uses two 59 watt bulbs, not included. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 12BK-SOLX500 Solid Single Building Wire Southwire 12WHT-SOLX500 Solid Single Building Wire Southwire 12RED-SOLX500 Tungsten Quartz Single Ended Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 12BLU-SOLX500 Solid Single Building Wire Southwire 12GRN-SOLX500 Solid Single Building Wire Acuity 111AFH Strip Light
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Fixture can be mounted individually or in continuous rows for surface or suspended mounting. Applications include light commercial, industrial, retail, coves and displays. Heavy-duty channel is die-formed from 22-gauge steel. Channel cover snaps to housing for easy access to wire way. Electrical connections are made inside the wire way. Standard mounting holes and wiring knockouts are included. Housing is finished in lighting grade white baked gloss enamel paint. No diffuser, fluorescent lamp is exposed. For use with 59 watt, 96" T8 slimline linear lamps. The fixture is cULus listed for damp locations.
Romex SIMpull 10/2NM-WGX50 Building Wire Romex SIMpull 12/2UF-WGX100 Building Wire LIGHT PUCK LED WIRELESS SET
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Includes 3 triple A batteries. 35 Lumens
Southwire 12GRN-STRX500 Stranded Single Building Wire Southwire 12BK-STRX500 Stranded Single Building Wire Southwire 12WHT-STRX500 Single Ended Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed.
Southwire 12RED-STRX500 Stranded Single Building Wire Southwire 12BLU-STRX500 Stranded Single Building Wire Southwire 12YEL-STRX500 Stranded Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed.
LED GROW LT FIXTRE 2FT19W RED Romex SIMpull 12/2NM-WGX250 Building Wire DESK LAMP LED 150L
DESK LAMP LED 150L
Our Price: $72.96
Fully assembled, dual 2ft LED grow light requires no lamps to replace. Rated for high humidity use. Instant full brightness. No humming. Includes 5 foot plug-in cord with on/off rocker switch and a 6 inch hanging wire harness. Linkable up to 8 fixtures. UL/CUL Listed FCC Compliant. 1.73"H x 23.3"L. 120 volt, 19 watts. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 14/2UF-W/GX250 Building Wire WIRE BUILDING 6/3NM-B W/G 25FT Romex SIMpull 14/3NM-WGX250 Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/3UF-WGX100 Type UF-B Building Wire Romex SIMpull 10/3UF-WGX50 Type UF-B Building Wire LIGHT BAR MOTION SMALL 250L
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 10/2UF-WGX50 Building Wire LIGHT BAR LARGE LED 350L      Armolite 68583423 Solid Metal Clad Cable
LIGHT BAR LARGE LED 350L
Our Price: $83.52
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
LIGHT BAR MOTION LARGE 350L   Southwire 10BK-SOLX500 Solid Single Building Wire Southwire 10WHT-SOLX500 Solid Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 10RED-SOLX500 Solid Single Building Wire Southwire 10GRN-SOLX500 Solid Single Building Wire TRACK LIGHT LED GRAY W/REMOTE
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Base with four independently swiveling, pivoting light heads with super-bright white LEDs. Choose from three power settings: on, dim, or off with a push button. Installation with the included hook and loop tape or mounting bracket. Runs on 6 AAA batteries (not included).
Romex SIMpull 10/3NM-WGX50 Building Wire Coleman 946016618 Speaker Wire Romex SIMpull 10/2UF-WGX100 Type UF-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Parallel wire, power limited circuit cable, -20 Celsius to 105 Celsius. Used for stereos and hi-fi systems, home theater sound systems, lamps, and radios. Soft annealed copper per ASTM B3-90 conductor and PVC. UL Type CL2, UL1581 and UL13 approved. Clear jacket, on a spool. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 12/3NM-WGX100 Type NM-B Building Wire Southwire 10BLU-SOLX500 Solid Single Building Wire Southwire 10WHT-STRX500 Stranded Single Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed.
Southwire 10GRN-STRX500 Stranded Single Building Wire Southwire 10BK-STRX500 Stranded Single Building Wire Southwire 10RED-STRX500 Stranded Single Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed.
Southwire 10BLU-STRX500 Stranded Single Building Wire Duraclad 55278301 Type MC Armored Cable Duraclad 55274901 Type MC Armored Cable
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
WIRE BUILDING 8/3NM-B W/G 50FT Romex SIMpull 10/2NM-WGX100 Type NM-B Building Wire Armorlite 68580001 Type MC Armored Cable
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Inner conductors are type THHN, ra