Home > ELECTRICAL > ROUGH ELECTRICAL > CONDUIT > METAL FLEX CONDUIT
Sort By:
1
BULB LED BR30 8.5W 2700K      LED S11 E17 1.5W/20W 80LM3000K S14 1.5W/11W MED SIGN LED3000K
Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Non-dimmable E17 base S11 LED replaces a 20 watt incandescent desk lamp bulb. It has an average life of 15,000 hours. Instant on to full brightness, indoor, suitable for damp locations. ETL Listed, FCC and RoHS Compliant and mercury free. 2.125"H x 1"D. Non-dimmable medium base, 1.5 watt S14 LED replaces an 11 watt incandescent sign lamp bulb. 80 lumen 3000K. Average life of 15,000 hours. Instant on to full brightness, indoor, suitable for damp locations. ETL Listed, FCC and RoHS Compliant and mercury free. 3.25"H x 1.5".
LED R20 850 DIM 5000K         BULB LED R20 DIM 6W 2700K     BULB LED BR30 DIM 9W 5000K
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Ultra LED, directional. Dimmable, medium aluminum base. Medium base, 120 volt, 25,000 hours average life.
BULB LED BR30 65W EQ DIMMABLE BULB LED BR30 65W EQ DIMMABLE LED R20 7.5W/45W MED DIM 2700K
Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free.
R20 7.5W/45W MED DIM  LED5000K LED R7S 5W/40W 450LUMENS 3000K LED DC BAYONET BS 3W/20W 3000K
Medium screw base. 120 volts. Instant on to full brightness. UL/CUL Listed, RoHS Compliant, Mercury free. Non-dimmable R7 base R7S LED. Average life of 15,000 hours, lights up instantly. For accent fixtures and torchiere table or floor lamps. 4.68"H x .875" D. UL/CUL Listed, FCC and RoHS Compliant, mercury free. Performance 3 watt LED is a 20 watt replacement, has an average life of 15,000 hours. 200 lumen 3000K. Instant on to full brightness, suitable for damp locations. ETL/CUL Listed, FCC and RoHS Compliant and mercury free. 2"H x .68"D.
LED7.5BR30DIM 7.5/65W EQV 5K  BULB LED 65W BR30 E26 27K 650L BULB LED 10YR 65W BR30 27K 2PK
Medium base, 120 volt, 25,000 hours average life. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant.
BULB LIGHT LED 10YR BR30 60W  BULB LED BR30 10YR DIM35K 65W BULB LED BR40 DIM 12W 2700K
Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Medium base, 120 volt, 25,000 hours average life.
BULB LED R20 10YR DIM 27K 50W BULB LED R20 10YR DIM 5K 50W  BULB LED R20 10YR DIM 35K 50W
Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant.
BULB LED BR40 DIM 12W 5000K   BULB LED BR40 DIM 12W 3500K   Southwire 55082415 Armored Cable
Medium base, 120 volt, 25,000 hours average life. Medium base, 120 volt, 25,000 hours average life. Wire whip, 14/3 AWG.
Feit BPMR11/LED Non-Dimmable LED Lamp LED R7S 8W/60W 800LUMENS 3000K BULB LED INTGRTD 27K 15W/65W
Performance LED, for track lighting. 12 volt, 240 lumens, 3000K, 38 degree beam angle, 25,000 average life hours. 1.5" MOL x 1.35" diameter. Instant on to full brightness. Suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant. Mercury free. Non-dimmable R7 base R7S LED. Average life of 15,000 hours, lights up instantly. For accent fixtures and torchiere table or floor lamps. 4.68"H x .875" D. UL/CUL Listed, FCC and RoHS Compliant, mercury free. Dimmable, 11,000 average life hours. E26 medium base.
LED BR40 10.5W/65W MED DIM 5K BULB LED BR40 DIMMABLE 5000K  BULB LED BR40 DIMMABLE 2700K
For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. For track lighting, recessed lighting. Instant on to full brightness. Indoor, suitable for damp locations. 120 volt, 110 degree beam spread, 6.3" MOL x 5" diameter. UL/CUL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free.
Armorlite 68580021 Type MC Armored Cable BULB LED BR30 65W DIMMABLE    Armorlite 68579221 Type MC Armored Cable
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Track and recessed lighting, Instant on to full brightness. 5" MOL x 3.75" diameter. Indoor-outdoor, suitable for damp locations. UL/CUL Listed, RoHS Compliant and mercury free. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
BULB LED BR40 HO35K 11K-HR 85W BULB LED BR40 DIM 27K 13W/85W BULB LED BR40 DIM 5K 13W/85W
Medium base, non dimmable, 11000 hours average life. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant. Dimmable down to 10 percent. Contain no mercury, lead or other hazardous materials. No UV or IR radiation. 120 volt. RoHS compliant.
Duraclad 55278321 Type MC Armored Cable Feit BR40/DM/2500/3K/L Dimmable LED Lamp Duraclad 55274921 Type MC Armored Cable
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. For track lighting. Instant on to full brightness. Suitable for damp locations. 25,000 average life hours. 120 volt, 110 degree beam spread. FCC Compliant. 100 percent mercury free. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Alflex FO5000025M Type RWA Reduced Wall Flexible Conduit Alflex FO7500025M Type RWA Reduced Wall Flexible Conduit Alflex FO3750050M Type RWA Reduced Wall Flexible Conduit
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Armorlite 68579222 Type MC Armored Cable Armorlite 68583421 Type MC Armored Cable Duraclad 55274922 Type MC Armored Cable
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Duraclad 55278521 Type MC Armored Cable Southwire UO5000025M Liquid Tight Flexible Conduit Duraclad 55275021 Type MC Armored Cable
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Armolite 68580022 Solid Metal Clad Cable Duraclad 55278322 Type MC Armored Cable Alflex FO5000050M Type RWA Reduced Wall Flexible Conduit
Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Alflex FO37501001 Type RWA Reduced Wall Flexible Conduit Alflex FO7500050M Type RWA Reduced Wall Flexible Conduit Armolite 68583422 Solid Metal Clad Cable
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Southwire UO7500025M Liquid Tight Flexible Conduit Armolite 68580023 Solid Metal Clad Cable Alflex FO75001001 Type RWA Reduced Wall Flexible Conduit
Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Duraclad 55278323 Type MC Armored Cable Duraclad 55274923 Type MC Armored Cable Southwire UO5000050M Liquid Tight Flexible Conduit
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
Alflex FO50001001 Type RWA Reduced Wall Flexible Conduit Armolite 68583423 Solid Metal Clad Cable Southwire UO7500050M Liquid Tight Flexible Conduit
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
Duraclad 55278301 Type MC Armored Cable Duraclad 55274901 Type MC Armored Cable Armorlite 68580001 Type MC Armored Cable
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems. Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications: Dry locations only, branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL Standard 4 for Armored Cable, UL Standard 83, Federal Specification A-A59544 (formerly J-C-30B), and the National Electrical Code. Listed for use in UL 1, 2, and 3 hour through-penetration firestop systems.
Southwire UO500001001 Liquid Tight Flexible Conduit Southwire UO75001001 Liquid Tight Flexible Conduit Armorlite 68583401 Type MC Armored Cable
Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Pre-installed conductors within an overall protective metallic interlocked armor. 45 percent lighter than steel MC cable. Cable reverse wound for ease of pulling and installation. Conductors - solid bare annealed copper per ASTM B-3, stranded copper stranding per ASTM B-8 for conductor. Conductor insulation rated 90 degree Celsius dry, 75 degrees Celsius wet at 600 volt. Conductor insulation is flame retardant, heat resistant PVC with flame, oil and gasoline resistant nylon jacket. General applications: branch, feeder, and service power distribution in commercial, industrial, institutional, and multi-residential construction/facilities, power, lighting, control, and signal circuits, concealed or exposed installations, installed in raceway/conduit, fished or embedded in plaster, installed in cable tray, and as aerial cable on a messenger. UL Classified 1, 2 and 3 hour through penetration firestop systems: W-L-3110, W-L-3113, W-L-31120, W-L-3121, C-A-J-3115, C-A-J-3140, C-A-J-3142, C-A-J-3202, C-A-J-4065, and C-A-J-4066. UL Listed.
Southwire 6SOLX315BARE Solid Electrical Wire Southwire 8SOLX500BARE Solid Electrical Wire Southwire 6STRDX315BARE Stranded Electrical Wire
Equipment and circuit grounding. Equipment and circuit grounding. Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems.
Southwire 4STRDX200BARE Stranded Electrical Wire Southwire 4SOLX200BARE Solid Electrical Wire Southwire 2SOLX125BARE Solid Electrical Wire
Flexible and easily shaped, formed, welded and soldered into place. Use in overhead transmission and distribution systems and for grounding grid systems. Equipment and circuit grounding. Equipment and circuit grounding.
Southwire 10SOLX800BARE Linear Electrical Wire Southwire SEU Service Entrance Cable Southwire SEU Service Entrance Cable Wire
Equipment and circuit grounding. Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius in wet or dry locations, 600 volt. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable Wire
Cross-linked polyethylene (XLPE) insulation. Insulated conductors laid parallel with bare ground wires helically wound around core. Covered with a reinforced binder tape. Sunlight resistant gray PVC jacket. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius in wet or dry locations, 600 volt. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable
Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 degrees Celsius in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944, and NEC requirements.
Southwire SER Service Entrance Cable Southwire 2-2-4-6X500AL USE In-Use Service Entrance Cable Wire Southwire SEU Service Entrance Cable
Used as a panel feed in multiple unit dwellings. May be used in wet or dry locations at temperatures not to exceed 90 degrees Celsius. 600 volt maximum. Meets or exceeds UL Standard 44 for type XHHW-2 conductors or UL Standard 83 for THHN/THWN conductors, UL Standard 854, Federal Specification A-A59544, NEC requirements. Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact stranded 8000 series aluminum alloy. 600 volt. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 degrees Celsius. Quadruplex cable conductor construction. UL Listed. Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 degrees Celsius in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944, and NEC requirements.
Southwire SEU Service Entrance Cable Wire Southwire SEU Service Entrance Cable Southwire MBL Service Entrance Cable Wire
Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit. Used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard. Also may be used for certain branch circuits as permitted by the NEC. Suitable for use at temperatures not to exceed 90 degrees Celsius in wet or dry locations. Meets or exceeds UL Standard 44 for Type XHHW-02 conductors or UL Standard 83 for Type THHN/THWN, UL Standard 854, Federal Specification A-A-5944, and NEC requirements. Used to connect mobile homes to a supply of electricity where permanent wiring is required as specific by NEC Article 550-24 and complies with NEC Article 338-1. Compact stranded 8000 series aluminum alloy. 600 volt. Cross-linked, polyethylene (XLPE). Types USE-2/RHH/RH, W-2. Approved for direct burial up to 90 degrees Celsius. Quadruplex cable conductor construction. UL Listed.
Southwire SER Service Entrance Cable Southwire SEU 13084905 Service Entrance Cable Wire
Used as a panel feed in multiple unit dwellings. May be used in wet or dry locations at temperatures not to exceed 90 degrees Celsius. 600 volt maximum. Meets or exceeds UL Standard 44 for type XHHW-2 conductors or UL Standard 83 for THHN/THWN conductors, UL Standard 854, Federal Specification A-A59544, NEC requirements. Above ground service entrance and branch circuit. Maximum operating temperature of phase conductors not to exceed 90 degrees Celsius for dry locations or 75 degrees Celsius for wet locations, 600 volt. Color coded phase conductors. Full or reduced neutral constructions. Fiberglass reinforced tape under the outer jacket. Sunlight and moisture resistant, flame retardant jacket. UL Listed. Amp capacities listed are at 30 degrees Celsius/85 degrees Fahrenheit.
   
 
1