Home > ELECTRICAL > ROUGH ELECTRICAL > CONDUIT > PVC CONDUIT
Choose a sub category:
DIMMABLE 12 VOLT DIMMABLE NON DIMMABLE
Sort By:
1
J-M 67447 Electrical Conduit J-M 67454 Electrical Conduit J-M 67611 Rigid Conduit
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end.
J-M 67462 Rigid Conduit Osram Sylvania 78563 LED Lamp J-M 67603 Rigid Conduit
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Candelabra base. For indoor use. Replacement for traditional incandescent C7 bulbs. 65,000K, 80 CRI. 15,000 hours average life. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end.
Feit BPC7/LED Mercury Free Accent LED Lamp J-M 67470 Rigid Conduit J-M 67488 Rigid Conduit
Candelabra screw base. Less than 1 watt, 7 watt replacement, 50,000 average life hours. 2.15" overall length. 3500K. Instant on to full brightness. RoHS Compliant, Mercury free. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end.
J-M 67595 Rigid Conduit J-M 67496 Rigid Conduit BULB LED G25 VINTAGE 4.5W/40W
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Indoor and outdoor use. 15,000 hours average life.
J-M 67587 Rigid Conduit J-M 67579 Rigid Conduit Romex SIMpull 14/2NM-WGX25 Building Wire
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 14/2UF-W/GX25 Building Wire J-M 67561 Rigid Conduit J-M 67504 Rigid Conduit
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end.
Romex SIMpull 12/2NM-WGX25 Building Wire Romex SIMpull 14/3NM-WGX25 Building Wire Romex SIMpull 12/2UF-W/GX25 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
J-M 67512 Rigid Conduit Romex SIMpull 14/2NM-WGX50 Building Wire Southwire 22955952 THHN Building Wire
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22957552 THHN Building Wire Southwire 22956752 THHN Building Wire Southwire 22959152 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
J-M 67553 Rigid Conduit Southwire 22955951 THHN Building Wire Southwire 22956751 THHN Building Wire
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22957551 THHN Building Wire Southwire 22959151 THHN Building Wire Southwire 22973236 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22974036 THHN Building Wire Southwire 22975736 THHN Building Wire Southwire 22977336 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Romex SIMpull 14/2UF-WGX50 Building Wire J-M 67546 Rigid Conduit Romex SIMpull 12/3NM-WGX25 Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Southwire 22966652 THHN Building Wire Southwire 22964152 THHN Building Wire Southwire 22968252 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22965852 THHN Building Wire Romex SIMpull 14/2NM-WGX100 Building Wire SIMpull 22964151 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
SIMpull 22965851 THHN Building Wire SIMpull 22966651 THHN Building Wire SIMpull 22968251 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Romex SIMpull 10/2NM-WGX25 Building Wire Romex SIMpull 12/2NM-WGX50 Building Wire Romex SIMpull 14/3NM-WGX50 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 10/2UF-W/GX25 Type UF-B Building Wire Romex SIMpull 12/2UF-WGX50 Building Wire Southwire 16BLK-STRX500 Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed.
Southwire 22973237 THHN Building Wire Southwire 22977337 THHN Building Wire Southwire 22974037 THHN Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant.
Southwire 22975737 THHN Building Wire Romex SIMpull 14/3UF-WGX50 Type UF-B Building Wire Romex SIMpull 14/2UF-WGX100 Building Wire
Primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications Thermoplastic insulation maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Standard 83, RoHS/REACH Compliant. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Southwire 14BK-SOLX500 Solid Single Building Wire Southwire 14WHT-SOLX500 Solid Single Building Wire Southwire 14RED-SOLX500 Solid Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 14GRN-SOLX500 Solid Single Building Wire Southwire 14BLUE-SOLX500 Solid Single Building Wire Southwire 14YEL-SOLX500 Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Romex SIMpull 10/3NM-WGX25 Building Wire Romex SIMpull 14/2NM-WGX250 Building Wire Southwire 14BK-STRX500 Stranded Single Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed.
Southwire 14GRN-STRX500 Stranded Single Building Wire Southwire 14WHT-STRX500 Stranded Single Building Wire Southwire 14RED-STRX500 Stranded Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed.
Southwire 14BLUE-STRX500 Stranded Single Building Wire Romex SIMpull 12/2NM-WGX100 Building Wire WIRE BUILDING 8/3NM-B W/G 25FT
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C.
Romex SIMpull 12/3NM-WGX50 Building Wire Romex SIMpull 10/2NM-WGX50 Building Wire Romex SIMpull 12/2UF-WGX100 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 12/3UF-WGX50 Type UF-B Building Wire Romex SIMpull 14/3NM-WGX100 Building Wire Southwire 12YEL-SOLX500 Solid Single Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 12BK-SOLX500 Solid Single Building Wire Southwire 12WHT-SOLX500 Solid Single Building Wire Southwire 12RED-SOLX500 Tungsten Quartz Single Ended Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 12BLU-SOLX500 Solid Single Building Wire Southwire 12GRN-SOLX500 Solid Single Building Wire Romex SIMpull 12/2NM-WGX250 Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Southwire 12GRN-STRX500 Stranded Single Building Wire Southwire 12BK-STRX500 Stranded Single Building Wire Southwire 12WHT-STRX500 Single Ended Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed.
Southwire 12RED-STRX500 Stranded Single Building Wire Southwire 12BLU-STRX500 Stranded Single Building Wire Southwire 12YEL-STRX500 Stranded Single Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC maximum 90 degrees Celsius. Moisture, heat, oil and gasoline resistant, 600 volt. Premium grade flame retardant PVC jacket. UL Listed.
Romex SIMpull 14/2UF-W/GX250 Building Wire WIRE BUILDING 6/3NM-B W/G 25FT Romex SIMpull 14/3NM-WGX250 Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 10/3NM-WGX50 Building Wire Romex SIMpull 10/2UF-WGX50 Building Wire Romex SIMpull 12/3UF-WGX100 Type UF-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 10/3UF-WGX50 Type UF-B Building Wire Southwire 10BK-SOLX500 Solid Single Building Wire Southwire 10WHT-SOLX500 Solid Single Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket.
Southwire 10RED-SOLX500 Solid Single Building Wire Southwire 10GRN-SOLX500 Solid Single Building Wire Romex SIMpull 12/3NM-WGX100 Type NM-B Building Wire
Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 10/2UF-WGX100 Type UF-B Building Wire Southwire 10BLU-SOLX500 Solid Single Building Wire Romex SIMpull 10/2NM-WGX100 Type NM-B Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Can replace TW, THW-RHH and RHW. Thermoplastic PVC 90 degrees Celsius nylon armored machine tool, building or fixture wire. UL Listed as 90 degrees MYW, 105 degrees CAWM moisture, oil and gasoline resistant. Premium grade flame retardant PVC jacket. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Southwire 10WHT-STRX500 Stranded Single Building Wire Southwire 10GRN-STRX500 Stranded Single Building Wire Southwire 10BK-STRX500 Stranded Single Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed.
Southwire 10RED-STRX500 Stranded Single Building Wire Southwire 10BLU-STRX500 Stranded Single Building Wire Romex SIMpull 12/2UF-W/GX250 Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
WIRE BUILDING 8/3NM-B W/G 50FT Romex SIMpull 14/3UF-WGX250 Type UF-B Building Wire Romex SIMpull 10/3UF-W/GX100 Type UF-B Building Wire
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 8/2NM-WGX125 Type NM-B Building Wire Romex SIMpull 10/3NM-WGX100 Type NM-B Building Wire Romex SIMpull 12/3NM-WGX250 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 28827472 Type NM-B Building Wire Romex SIMpull 10/2NM-WGX250 Type NM-B Building Wire WIRE BUILDING 6/3NM-B W/G 50FT
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C.
Romex SIMpull 12/3UF-WGX250 Type UF-B Building Wire Southwire 8BLK-STRX500 Stranded Single Building Wire Southwire 8WHT-STRX500 Stranded Single Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed.
Southwire 8RED-STRX500 Stranded Single Building Wire Southwire 20492512 Stranded Single Building Wire Romex SIMpull 6/2NM-WGX125 Type NM-B Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 8/3NM-WGX125 Type NM-B Building Wire Romex SIMpull 28828272 Type NM-B Building Wire Romex SIMpull 14/2NM-WGX1000 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 63946872 Type NM-B Building Wire Romex SIMpull 12/2NMW/GX500FT Type NM-B Building Wire Romex SIMpull 10/2UF-W/GX250 Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 63947672 Type NM-B Building Wire Romex SIMpull 10/3NM-WGX250 Type NM-B Building Wire Romex SIMpull 8/2UF-W/GX125 Type UF-B Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Romex SIMpull 63949272 Type NM Building Wire Southwire 6GRN-STRX500 Stranded Single Building Wire Southwire 6BK-STRX500 Stranded Single Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed.
Southwire 6WHT-STRX500 Stranded Single Building Wire Southwire 6RED-STRX500 Stranded Single Building Wire Romex SIMpull 63948472 Type NM-B Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 6/3NM-WGX125 Type NM-B Building Wire Romex SIMpull 10/3UF-WGX250 Type UF-B Building Wire Romex SIMpull 12/2NM-WGX1000 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 28829072 Type NM-B Building Wire Romex SIMpull 63950072 Type NM-B Building Wire Romex SIMpull 6/2UF-W/GX125 Type UF-B Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed.
Southwire 4GRN-STRX500 Stranded Single Building Wire Southwire 4BK-STRX500 Stranded Single Building Wire Southwire 4WH-STRX500 Stranded Single Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed.
Romex SIMpull 14/2UF-W/GX1000 Type UF-B Building Wire Romex SIMpull 12/2UF-WGX500 Type UF-B Building Wire Romex SIMpull 8/2NM/WG 500 FT Type NM-B Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Southwire 3BK-STRX500 Stranded Single Building Wire Romex SIMpull 12/2UF-W/GX1000 Type UF-B Building Wire Romex SIMpull 14/3NM-WGX1000FT Type NM-B Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 12/3NM-WGX1000FT Type NM-B Building Wire Romex SIMpull 10/2NM-WGX1000 Type NM-B Building Wire Southwire Stephens Triplex Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Consists of two cross-linked polyethylene insulated phase conductors triplexed with a yellow-striped, cross-linked polyethylene insulated neutral. High quality heat and moisture-resistant cross-linked polyethylene is rated 75 degrees Celsius for wet and 90 degrees Celsius for dry locations. 120 amp maximum in duct or 165 amp in direct earth burial applications with a maximum conductor temperature of 90 degrees Celsius, 600 volt. 2 - 2 - 4 URD x 500' spool. UL Listed.
Romex SIMpull 6/2NM-WGX500 Type NM-B Building Wire Southwire 2BK-STRX500 Linear Building Wire Romex SIMpull 8/3NM-W/GX500 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Southwire 2WHT-STRX500 Stranded Single Building Wire Southwire 1BLK-STRX500 Stranded Single Building Wire Romex SIMpull 10/3NM-WGX1000FT Type NM-B Building Wire
Premium grade flame retardant PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. 500' spool. UL Listed. Premium grade flame retardant black PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. UL Listed. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 10/2UF-W/GX1000 Type UF-B Building Wire Southwire 1/0BK-STRX500 Stranded Single Building Wire Romex SIMpull 6/3NM-W/GX500 Type NM-B Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Premium grade flame retardant black PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 6/2UF-W/GX500 Type UF-B Building Wire Southwire 2/OBK-STRX500 3-Way Torchiere Building Wire Southwire Sweetbriar Triplex Building Wire
Type THHN insulation, rated 90 degrees Celsius, 600 volt. Gray PVC jacket. For applications of direct burial, dwellings not exceeding 3 floors above grade, underground feeder to outdoor lighting or apparatus, exposed or concealed wiring in damp, moist, wet, dry, and corrosive locations, general branch circuit wiring and new wiring or replacement wiring. Flame retardant, moisture, fungus, and corrosion resistant. Sunlight resistant jacket. JC-30B Federal specification, ASTM B-3, ASTM B-8 and NY state DOS 16120-880923-2002. UL Listed. Premium grade flame retardant black PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. UL Listed. Compact stranded 8000 series aluminum alloy. Cross-linked polyethylene (XLPE) insulation. Multiplexed cable conductors with a left hand lay in a Triplex (3 conductor) assembly. Underground distribution from a supply source to the service entrance equipment of a building. Maximum operating temperature of 90 degrees Celsius in dry and wet locations. 315 amp maximum in direct burial application or 240 amp in ducts. 4/0 - 4/0 - 2/0 x 500' spool, 600 volt. Black color. UL Listed Type USE-2.
Southwire Monmouth Triplex Building Wire Southwire 3/0BK-STRX500 Stranded Single Building Wire
Consists of two cross-linked polyethylene insulated phase conductors triplexed with a yellow-striped, cross-linked polyethylene insulated neutral. High quality heat and moisture-resistant cross-linked polyethylene is rated 75 degrees Celsius for wet and 90 degrees Celsius for dry locations. 240 amp maximum in duct or 315 amp in direct earth burial applications with a maximum conductor temperature of 90 degrees Celsius, 600 volt. 4/0 - 4/0 - 4/0 URD x 500' spool. UL Listed. Premium grade flame retardant black PVC jacket. Rated maximum 90 degrees Celsius dry and damp, 600 volt. General purpose building wire for services, feeders and branch circuits. Resistant to abrasion, acids, alkalines, ozone, and water. UL Listed.
   
 
1