Home > ELECTRICAL > ROUGH ELECTRICAL > CONDUIT
Choose a sub category:
METAL CONDUIT - EMT PVC CONDUIT METAL CONDUIT - RIGID
PLASTIC FLEXIBLE CONDUIT METAL FLEX CONDUIT
Sort By:
1
J-M 67447 Electrical Conduit J-M 67454 Electrical Conduit Carlon 12005-UPC Flexible Raceway
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed.
J-M 67611 Rigid Conduit Allied 101543 EMT Electrical Conduit J-M 67462 Rigid Conduit
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end.
J-M 67603 Rigid Conduit Carlon 12007-UPC Flexible Raceway LED G25 2.5W/25W MED DIM 2700K
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed. Used for bath and vanity. Instant on to full brightness. Indoor, suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free.
J-M 67470 Rigid Conduit G25 2.5W 827 DIM LED2700K FRST LED G25 MED 4.5W 827 DIM 2700K
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Used for bath and vanity. Instant on to full brightness. Indoor, suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. Used for bath and vanity. Instant on to full brightness. Indoor, suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free.
LED G25 MED 4.5W 850 DIM 5000K BULB LED FILAMENT 40W EQUIV   G25 4.5W 850 DIM LED5000K FRST
Used for bath and vanity. Instant on to full brightness. Indoor, suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. Used for bath and vanity. Instant on to full brightness. Indoor, suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. Used for bath and vanity. Instant on to full brightness. Indoor, suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free.
LED G25 MED 5W 827 DIM 2700K  LED G25 MED 5W/60W CLEAR 5000K Allied 101550 EMT Electrical Conduit
Used for bath and vanity. Instant on to full brightness. Indoor, suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. Used for bath and vanity. Instant on to full brightness. Indoor, suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3.
LED G25 MED 5W/60W FROST 2700K LED G25 MED 5W/60W FROST 5000K J-M 67488 Rigid Conduit
Used for bath and vanity. Instant on to full brightness. Indoor, suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. Used for bath and vanity. Instant on to full brightness. Indoor, suitable for damp locations. UL Listed, FCC Compliant, RoHS Compliant, 100 percent mercury free. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end.
BULB LED G25 DIM 4.5W 2700K   J-M 67595 Rigid Conduit J-M 67496 Rigid Conduit
Indoor and outdoor use. 15,000 hours average life. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end.
Feit G4/LED Non-Dimmable LED Lamp Feit G8/LED Non-Dimmable LED Lamp Feit G9/LED Non-Dimmable LED Lamp
Performance LED, 20 watt replacement, has an average life of 15,000 hours and is mercury free. 3000K, 160 lumens. Energy saving, non-dimmable. Performance LED, 20 watt replacement, has an average life of 15,000 hours and is mercury free. 3000K, 160 lumens. Energy saving, non-dimmable. Performance LED, 20 watt replacement, has an average life of 15,000 hours and is mercury free. 3000K, 160 lumens. Energy saving, non-dimmable.
LED GY6.35 BASE 2.5W/20W 3000K LED GY8.6 BASE 2.5W/20W 3000K WEDGE BASE 2W/20W 12V LED3000K
Non-dimmable LED, 2.5 watt, 120 volt, 3000K. Performance LED is a 20 watt replacement, has an average life of 15,000 hours. Instant on to full brightness, suitable for damp locations. ETL/CUL Listed, FCC and RoHS Compliant and mercury free. 1.75"H x 0.75"D. Non-dimmable LED, 2.5 watt, 120 volt, 3000K. Performance LED is a 20 watt replacement, has an average life of 15,000 hours. Instant on to full brightness, suitable for damp locations. ETL/CUL Listed, FCC and RoHS Compliant and mercury free. 1.75"H x 0.75"D. Non-dimmable LED, 2 watt, 12 volt wedge base. 160 lumens, 3000K. Performance LED, 20 watt replacement. Average life of 15,000 hours. Instant on to full brightness. Suitable for damp locations. FCC and RoHS Compliant, mercury free. 1.9"h x .60"D.
BULB LED FILAMENT 40W EQUIV   LED G16-1/2 827 4.5W DIM 2700K BULB LED G25 VINTAGE 4.5W/40W
Candelabra base. Instant on to full brightness, suitable for damp locations.  UL/CUL Listed, FCC and RoHS Compliant and mercury free. Dimmable clear medium base G16-1/2 LED globe is a direct replacements for an incandescent bulb. Average life of 15,000 hours. Instant on to full brightness. Suitable for damp locations. UL/CUL Listed, FCC and RoHS Compliant, mercury free. 3H" x 2"D. Indoor and outdoor use. 15,000 hours average life.
J-M 67587 Rigid Conduit LED G16-1/2 CAND 6W 827 2700K G16-1/2 MED 6W 827DIM LED2700K
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Candelabra base. Instant on to full brightness, suitable for damp locations.  UL/CUL Listed, FCC and RoHS Compliant and mercury free. Dimmable clear medium base G16-1/2 LED globe is a direct replacements for an incandescent bulb. Average life of 15,000 hours. Instant on to full brightness. Suitable for damp locations. UL/CUL Listed, FCC and RoHS Compliant, mercury free. 3H" x 2"D.
CONDUIT NON-MET FLEX 1/2 X 25 Allied 101568 EMT Conduit J-M 67579 Rigid Conduit
For the installation and protection of electrical conductors in circuits of 600 volts or less. Manufactured with a spiral of rigid PVC reinforcement imbedded within a flexible PVC wall. Impact and crush resistant, liquid tight and highly flexible. UV sunlight resistant jacket. Rated for temperature range of -30 to 80 degrees C , 60 degrees C Oil (-22 to +176, 140 degrees F Oil). UL Listed. High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end.
Thomas & Betts 150DRB Liquidtight Flexible/Non-Metallic Conduit Kit Southwire 55189401 Liquid Tight Flexible Whip Romex SIMpull 14/2NM-WGX25 Building Wire
Contains everything necessary for complete installation including 6' conduit, two straight fittings and one 90 degree fitting. Totally non-metallic system provides assured grounding for safety. Non-conductive, non-corrosive. Easy to install. UL Listed components. Resistant to rust, cracks, and separation. Constructed with two different PVC materials. 600 volt stranded copper THHN/THWN conductors and UL Listed LFNC-B fittings. Twelve-inch wire leads are left exposed at each end. Green insulated copper grounding conductor. Intended for 208/240/480 volt. UL / CSA, complies with NEC Article 356. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
J-M 67561 Rigid Conduit Thomas & Betts 150ERB-UPC Liquidtight Flexible/Non-Metallic Conduit Kit J-M 67504 Rigid Conduit
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Contains everything necessary for complete installation including 6' conduit, two straight fittings and one 90 degree fitting. Totally non-metallic system provides assured grounding for safety. Non-conductive, non-corrosive. Easy to install. UL Listed components. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end.
Romex SIMpull 12/2NM-WGX25 Building Wire Allied 103051 Rigid Conduit Allied 101576 EMT Conduit
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1. High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3.
Romex SIMpull 14/3NM-WGX25 Building Wire Southwire 55189301 Liquid Tight Flexible Whip J-M 67512 Rigid Conduit
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Resistant to rust, cracks, and separation. Constructed with two different PVC materials. 600 volt stranded copper THHN/THWN conductors and UL Listed LFNC-B fittings. Twelve-inch wire leads are left exposed at each end. Green insulated copper grounding conductor. Intended for 208/240/480 volt. UL / CSA, complies with NEC Article 356. Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end.
Allied 103069 Rigid Conduit Ultratite 55094321 Liquid Tight Flexible Conduit Alflex FO3750050M Type RWA Reduced Wall Flexible Conduit
High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1. For the installation and protection of electrical conductors in circuits of 600 volts or less. Manufactured with a spiral of rigid PVC reinforcement imbedded within a flexible PVC wall. Impact and crush resistant, liquid tight and highly flexible. UV sunlight resistant jacket. Rated for temperature range of -30 to 80 degrees C , 60 degrees C Oil (-22 to +176, 140 degrees F Oil). UL Listed. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Allied 101584 EMT Conduit Romex SIMpull 14/2NM-WGX50 Building Wire Alflex FO5000025M Type RWA Reduced Wall Flexible Conduit
High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
J-M 67553 Rigid Conduit Alflex FO7500025M Type RWA Reduced Wall Flexible Conduit Allied 101592 EMT Conduit
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. High grade mild strip steel, hot galvanized with a process that combines zinc, a conversion coating, and a clear organic polymer top-coat to form a triple layer of protection against corrosion and abrasion, has a low friction ID coating that improves the slip properties between conduit and wire. It provides easy bending, cutting and joining while resisting flattening, kinking and splitting. Reduces electromagnetic fields, effectively shielding computers and sensitive electronic equipment from the electromagnetic interference caused by power distribution systems. UL Listed, meets ANSI C80.3.
J-M 67546 Rigid Conduit Romex SIMpull 12/3NM-WGX25 Building Wire Southwire UO5000025M Liquid Tight Flexible Conduit
Safe, non-conductive. Used to protect electrical wiring in aboveground and underground applications. Easy to install. Will not rust or corrode. Compatible with ENT fittings with the use of ENT cement. Furnished in standard 10' lengths with one bell end. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
Romex SIMpull 14/2NM-WGX100 Building Wire Allied 103077 Rigid Conduit Romex SIMpull 10/2NM-WGX25 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/2NM-WGX50 Building Wire Romex SIMpull 14/3NM-WGX50 Building Wire Alflex FO37501001 Type RWA Reduced Wall Flexible Conduit
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Alflex FO5000050M Type RWA Reduced Wall Flexible Conduit Carlon 12007-100 Flexible Raceway Carlon 15005-100 Liquid Tight Flexible Conduit
Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed. Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed.
Allied 109085 Rigid Conduit Alflex FO7500050M Type RWA Reduced Wall Flexible Conduit Romex SIMpull 10/3NM-WGX25 Building Wire
High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 14/2NM-WGX250 Building Wire Carlon 15007-100 Liquid Tight Flexible Conduit Romex SIMpull 12/2NM-WGX100 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Carlon 12005-200 Flexible Raceway Allied 103093 Rigid Conduit Southwire UO7500025M Liquid Tight Flexible Conduit
Designed for use with 90 degree Celsius conductors, the hand bendable conduit offers the safety of assured grounding. For 600 volt use in walls, floors and ceilings in residential, commercial and industrial buildings not more than three floors above grade. Colored in brilliant electric blue. For indoor use. UL Listed. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound.
WIRE BUILDING 8/3NM-B W/G 25FT Romex SIMpull 12/3NM-WGX50 Building Wire Alflex FO75001001 Type RWA Reduced Wall Flexible Conduit
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Romex SIMpull 10/2NM-WGX50 Building Wire Southwire UO5000050M Liquid Tight Flexible Conduit Alflex FO50001001 Type RWA Reduced Wall Flexible Conduit
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Half the weight of steel AC, no couplings, elbows, or special bending tools required. Cuts up to 5 times faster than steel MC. Rated at 90 degrees Celsius. Conforms to UL Standard No. 1569 and Article 334.
Romex SIMpull 14/3NM-WGX100 Building Wire Allied 103101 Rigid Conduit Romex SIMpull 12/2NM-WGX250 Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
WIRE BUILDING 6/3NM-B W/G 25FT Romex SIMpull 14/3NM-WGX250 Building Wire Romex SIMpull 10/3NM-WGX50 Building Wire
Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 12/3NM-WGX100 Type NM-B Building Wire Southwire UO7500050M Liquid Tight Flexible Conduit Romex SIMpull 10/2NM-WGX100 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Carlon 15008-100 Liquid Tight Flexible Conduit WIRE BUILDING 8/3NM-B W/G 50FT Allied 103119 Rigid Conduit
Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C. High-strength mild steel, impact and crush resistant, ductile for long life and easy bending. Provides radiation protection and magnetic shielding. Hot-dipped galvanized with a smooth baked on lacquer coating inside and out for high grade, durable pipe protection. With one coupling. 10 foot length. Listed to Safety Standard UL 6. Manufactured in accordance with ANSI C80.1.
Southwire UO500001001 Liquid Tight Flexible Conduit Romex SIMpull 8/2NM-WGX125 Type NM-B Building Wire Carlon 15011-050 Liquid Tight Flexible Conduit
Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Lightweight and extremely flexible. Abrasion, corrosion, crush and strain resistant. For use with 90 degree Celsius conductors. Cold, heat and sunlight resistant. Dimensions conform to industry standards permitting the use of standard liquid tight fittings. For temperature ranges of 10 to 125 degrees Fahrenheit. Has a hard PVC spiral completely surrounded by a flexible PVC jacket. Impervious to weather. Use for outdoor lighting, water processing and pollution control, marina wiring, greenhouse wiring and transformer connections. For moving machinery controls/motors and machine tools. Use on heating, cooling and ventilation wiring; mounts easily for air conditioning and heat pumps. UL Listed.
Romex SIMpull 10/3NM-WGX100 Type NM-B Building Wire Romex SIMpull 12/3NM-WGX250 Type NM-B Building Wire Romex SIMpull 28827472 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 10/2NM-WGX250 Type NM-B Building Wire Southwire UO75001001 Liquid Tight Flexible Conduit WIRE BUILDING 6/3NM-B W/G 50FT
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Clean, smooth metal interior for easy wire-pulling and requires no special tools for cutting or bending. Type UL sunlight resistant and integral copper ground wire for use where UL Listing is required. Provides the safest possible protection from moisture, oil, chemicals, acid, alkaline and ozone. Tough Ultrabond, anchored polyvinyl chloride, extruded cover seals the spirally-wound, square-locked flexible galvanized steel core. Eliminates maintenance and downtime due to wiring failure. Approved for use in temperatures from 80 degrees Celsius dry, 60 degrees Celsius wet, 34 degrees Celsius cold. PVC jacket is made with a sunlight resistant UL compound. Primarily used in residential wiring as branch circuits for outlets, switches and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C.
Romex SIMpull 6/2NM-WGX125 Type NM-B Building Wire Romex SIMpull 8/3NM-WGX125 Type NM-B Building Wire Romex SIMpull 28828272 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 14/2NM-WGX1000 Type NM-B Building Wire Romex SIMpull 63946872 Type NM-B Building Wire Romex SIMpull 12/2NMW/GX500FT Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 63947672 Type NM-B Building Wire Romex SIMpull 10/3NM-WGX250 Type NM-B Building Wire Romex SIMpull 63949272 Type NM Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 63948472 Type NM-B Building Wire Romex SIMpull 6/3NM-WGX125 Type NM-B Building Wire Romex SIMpull 12/2NM-WGX1000 Type NM-B Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 28829072 Type NM-B Building Wire Romex SIMpull 63950072 Type NM-B Building Wire Romex SIMpull 8/2NM/WG 500 FT Type NM-B Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 14/3NM-WGX1000FT Type NM-B Building Wire Romex SIMpull 12/3NM-WGX1000FT Type NM-B Building Wire Romex SIMpull 10/2NM-WGX1000 Type NM-B Building Wire
Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
Romex SIMpull 6/2NM-WGX500 Type NM-B Building Wire Romex SIMpull 8/3NM-W/GX500 Type NM-B Building Wire Romex SIMpull 10/3NM-WGX1000FT Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground. Annealed (soft) copper conductor cable, with a ground wire, primarily used in residential wiring as branch circuits for outlets, switches, and other loads. May be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degrees C (with ampacity limited to that for 60 degree C conductors) as specified in the National Electrical Code 1. May be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600 volts. 3 conductors, 1,000 foot spool. Meets or exceeds UL Standard 83, UL Standard 719, Federal Specification A-A-59544, and requirements of the National Electrical Code.
Romex SIMpull 6/3NM-W/GX500 Type NM-B Building Wire
Inner conductors are type THHN, rated 90 degrees Celsius, 600 volt. Solid strands. Outer jacket is PVC, rated at 75 degrees Celsius. Amp rating of the product is limited to that for 60 degrees Celsius rated conductors per the National Electric Code Article 336. Dwellings not exceeding 3 floors above grade. Exposed or concealed wiring. May be fished through walls, ceilings, and masonry blocks. Use for new wiring or replacement wiring. Only for use in normally dry locations. UL Listed. /2 = 2 insulated wires with bare ground. /3 = 3 insulated wires with bare ground.
   
 
1