Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - GFCI
Sort By:
1
BULB REPL HAL WORKLTS T3 500W Feit BPQ250T3/CL/S Dimmable Short Halogen Lamp Feit BPQ100T3/CL/S Dimmable Short Halogen Lamp
Bright white light for halogen flood lamps, floor lamps and worklights. 500 watt, T3. Bright, white light for halogen flood lamps, floor lamps and worklights. 2,000 average life hours. 3-1/8" overall length, 120 volt. Bright, white light for halogen flood lamps, floor lamps and worklights. 2,000 average life hours. 3-1/8" overall length, 120 volt.
Feit Q300T3/CL-130 Dimmable Halogen Lamp Feit Q500T3/CL-130 Dimmable Halogen Lamp Feit BPQ150T3/CL Dimmable Halogen Lamp
Bright, white light for halogen flood lamps, floor lamps and worklights. 2,000 average life hours; 4,000 hours for 130 volt lamps used on a 120 volt line. 4-11/16" overall length. Bright, white light for halogen flood lamps, floor lamps and worklights. 2,000 average life hours; 4,000 hours for 130 volt lamps used on a 120 volt line. 4-11/16" overall length. Bright, white light for halogen flood lamps, floor lamps and worklights. 2,000 average life hours; 4,000 hours for 130 volt lamps used on a 120 volt line. 4-11/16" overall length.
Feit Energy Saver Dimmable Halogen Lamp Osram Sylvania 58516 Tungsten Halogen Lamp Osram Sylvania 58514 Tungsten Halogen Lamp
Compact and dimmable. Carded. Dichroic reflector cover. EXN ANSI code. 100 CRI. 1.75" maximum length, 2" diameter, 2000 hours average life. 3000K color temperature. No transformer required. A clear shield enables the lamp to operate in open fixtures. Low-pressure design. Constant luminous intensity and constant color location throughout its entire life. Fully dimmable with regular incandescent dimmers. 2000 hours average life. 3000K color temperature.
Feit BPQ300T3/CL Dimmable Halogen Lamp Osram Sylvania 58920 Tungsten Quartz Double Ended Halogen Lamp Osram Sylvania 58865 Tungsten Quartz Double Ended Halogen Lamp
Bright, white light for halogen flood lamps, floor lamps and worklights. 2,000 average life hours; 4,000 hours for 130 volt lamps used on a 120 volt line. 4-11/16" overall length. Clear finish tungsten halogen bulb. Operates in horizontal position. 4-11/16 overall length. 120 volt. Clear finish tungsten halogen bulb. Operates in horizontal position. 4-11/16 overall length. 120 volt.
Osram Sylvania 59075 Non-Ground  Halogen Lamp Capsylite 59076 Tungsten Ecologic Halogen Lamp Feit 35PAR30/L/QFL/ES Dimmable Halogen Lamp
Hard glass halogen capsule with bright white, high quality halogen light. Clear cover lens and facetted aluminized reflector. Specifications: 30 degree beam angle. Average rated life (hr) 3000. Applications: Task lighting, small aperture down lighting. Carded. Hard glass halogen capsule with bright white, high quality halogen light. Clear cover lens and facetted aluminized reflector. Specifications: 30 degree beam angle. Average rated life (hr) 3000. Applications: Task lighting, small aperture down lighting. Carded. Helps save energy compared to standard halogen bulb by adding Xenon gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, 560 lumens, medium E26 base. Instant on to full brightness, dimmable. 50 watt equivalent.
Feit 55PAR30/L/QFL/ES Dimmable Halogen Lamp Feit BPQ150T3 Dimmable Short Halogen Lamp Feit BPQ300T3/CL/RS/2 Dimmable Halogen Lamp
Helps save energy compared to standard halogen bulb by adding XENON gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, medium E26 base. Instant on to full brightness, dimmable. Bright, white light for halogen flood lamps, floor lamps and worklights. Use in any fixture for halogen bulbs; sturdier with multiple filament supports to resist vibration and with pinched glass to help hold filament in place for worklight applications. Brass plated contacts for corrosion resistance. 3000K, 4,000 average life hours. 130 volts. Clear. Bright, white light for halogen flood lamps, floor lamps and worklights. Use in any fixture for halogen bulbs; sturdier with multiple filament supports to resist vibration and with pinched glass to help hold filament in place for worklight applications. Brass plated contacts for corrosion resistance. 3000K, 4,000 average life hours. 130 volts. Clear.
Feit BPQ500T3/CL/RS/2 Dimmable Halogen Lamp Osram Sylvania 58887 Tungsten Quartz Double Ended Halogen Lamp Osram Sylvania 58886 Tungsten Quartz Double Ended Short Halogen Lamp
Bright, white light for halogen flood lamps, floor lamps and worklights. Use in any fixture for halogen bulbs; sturdier with multiple filament supports to resist vibration and with pinched glass to help hold filament in place for worklight applications. Brass plated contacts for corrosion resistance. 3000K, 4,000 average life hours. 130 volts. Clear. Clear finish tungsten halogen, ecologic bulb. Operates in any position. 2,000 average life hours. 120 volt, carded. Clear finish tungsten halogen, ecologic bulb. Operates in any position. 2,000 average life hours. 120 volt, carded.
Osram Sylvania 58885 Tungsten Quartz Double Ended Halogen Lamp Osram Sylvania 16103 Tungsten Ecologic Halogen Lamp Osram Sylvania 16104 Tungsten Ecologic Halogen Lamp
Clear finish tungsten halogen bulb. Operates in horizontal position. 4-11/16 overall length. 120 volt. Use indoor or out. 3.25" overall length. 100 CRI. Ecologic. Improved lamp efficiency to meet EISA requirements, up to 33 percent energy savings over standard full wattage lamps. Familiar shapes. Crisp, vivid 100 CRI light, mercury free, instant on. Made in the USA. RoHS compliant.  average life hours. Boxed.
Capsylite 16728 Tungsten Halogen Lamp Capsylite 16731 Tungsten Halogen Lamp Capsylite 16737 Tungsten Halogen Lamp
Use indoor or out. Averages 1,500 life hours. 5.313" overall length. 10 degree beam angle. PAR-38, boxed. Averages 3,000 life hours. 5.313" overall length. 25 degree beam angle. Use indoor or out. PAR-38, 120 volt, boxed Use indoor or out. Averages 1,500 life hours. 5.313" overall length. 10 degree beam angle. PAR-38, boxed.
Capsylite 16735 Tungsten Halogen Lamp Osram Sylvania 16154 Tungsten Ecologic Halogen Lamp Capsylite 16119 Halogen Lamp
Averages 1,500 life hours. 5.313" overall length. 25 degree horizontal beam angle. 850 lumens. 99 CRI. State of the art SPL Optics. Ecologic, use indoor or out. PAR-38, 120 volt. Tungsten halogen bulb with brighter, more natural light. 25 degree beam angle. Replaces BR30 bulbs. 2,500 average life hours. 4-11/16" overall length. 120 volt, boxed. Use indoor or out. 3.625" overall length. 50 degree beam angle. Ecologic. 1500 average life hours. 120 volt, boxed.
Osram Sylvania 16153 Tungsten Halogen Lamp Osram Sylvania 16156 Tungsten Halogen Lamp Osram Sylvania 16117  Halogen Lamp
Use indoors or out. 4.625" overall length. 10 degree beam angle. Ecologic. Boxed. Use indoors or out. 50 degree beam angle. Ecologic. 120 volt. Use indoor or out. Tungsten bulb, 2,500 average life hours. 3-5/8" overall length. E-26 medium base.
Feit 35PAR38/QFL/ES Dimmable Halogen Lamp Feit 38PAR20/QFL/ES Dimmable Halogen Lamp Feit BPQ500/MP-130- Dimmable Halogen Lamp
Helps save energy compared to standard halogen bulb by adding XENON gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, 580 lumens, medium E26 base. Instant on to full brightness, dimmable. 5" height x 4.75" depth. Helps save energy compared to standard halogen bulb by adding Xenon gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, 530 lumens, medium E26 base. Instant on to full brightness, dimmable. Bright, white light for halogen flood lamps, floor lamps and worklights. 130 volt. 4,000 hours when used on a 120 volt line. 4-11/16" overall length.
Capsylite 16738 Tungsten Ecologic Halogen Lamp Feit 35PAR30/S/QFL/ES Dimmable Halogen Lamp Feit 55PAR30/S/QFL/ES Dimmable Halogen Lamp
Tungsten bulb, 1,500 average life hours. 5.3" overall length. Boxed. Helps save energy compared to standard halogen bulb by adding Xenon gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, 560 lumens, medium E26 base. Instant on to full brightness, dimmable. 50 watt equivalent. Helps save energy compared to standard halogen bulb by adding XENON gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, medium E26 base. Instant on to full brightness, dimmable.
Feit 70PAR38/QFL/ES Dimmable Halogen Lamp Feit 55PAR38/QFL/ES Dimmable Halogen Lamp Feit 85PAR38/QFL/ES Dimmable Halogen Lamp
Helps save energy compared to standard halogen bulb by adding XENON gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, medium E26 base. Instant on to full brightness, dimmable. Helps save energy compared to standard halogen bulb by adding XENON gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, medium E26 base. Instant on to full brightness, dimmable. Helps save energy compared to standard halogen bulb by adding XENON gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, medium E26 base. Instant on to full brightness, dimmable.
Osram Sylvania 16745 Halogen Lamp Capsylite 15539 Tungsten Halogen Lamp Osram Sylvania 16129 Tungsten Halogen Lamp
Averages 2,500 life hours. 5.31" overall length. State of the Art SPL Optics. Ecologic, use indoors or out. PAR-38, 70/120 volt, boxed. Tungsten bulb, ecologic. 5.31" overall length. 9 degree beam angle. State of the art SPL Optics. Boxed. Use indoor or out. 3.625" overall length. 50 degree beam angle. Ecologic. 1500 average life hours. 120 volt, boxed.
Osram Sylvania 16127 Tungsten Ecologic Halogen Lamp Osram Sylvania 16552 Tungsten Double Life Halogen Lamp Feit BPXN50MR16/GU10/2 Dimmable Xenon Lamp
Use indoor or out. Silver reflector lamp, average 1,500 life hours. 3.625" overall length. 2900K, 99 CRI, 10 degree beam angle. Ecologic. Use indoors or out. 50 degree beam angle. Ecologic. 120 volt. Uses for track lighting. Produces a whiter, brighter light, runs cooler and lasts longer than halogen bulbs. 120 volts, 3000K, 3500 average life hours. 2" MOL x 2" diameter.
Osram Sylvania 16166 Tungsten Halogen Lamp Osram Sylvania 16167 Tungsten Halogen Lamp Osram Sylvania 16168 Tungsten Halogen Lamp
Use indoors or out. 4.625" overall length. 10 degree beam angle. Ecologic. Boxed. Tungsten halogen bulb with brighter, more natural light. 25 degree beam angle. Replaces BR30 bulbs. 1,500 average life hours. 1070 lumens, 2900K. Boxed. Wide flood, 50 degree beam, E26 medium base. 1070 lumens, 2900K, 99 CRI, 3.752" diameter, 4.625 overall length.
Capsylite 16585 Tungsten Ecologic Double Life Halogen Lamp Capsylite 16580 Tungsten Double Life Halogen Lamp Capsylite 16748 Tungsten Ecologic Halogen Lamp
Averages 3,000 life hours. 5.313" overall length. 25 degree beam angle. Use indoor or out. PAR-38, 120 volt, boxed Averages 3,000 life hours. 5.313" overall length. 25 degree beam angle. Use indoor or out. PAR-38, 120 volt, boxed Heat resistant, hard glass, suitable for indoor and outdoor use. Operate only in porcelain or other socket approved for 80 watt PAR lamps. 80 watt 120 volt incandescent PAR 38 narrow floodlight, 1545 approximate lumens, 99 CRI, E26 reflector lamp, 2950K, medium skirted base, 25 degree beam angle, 6000 candlepower, 5.313" length.
Osram Sylvania 16747 Tungsten Halogen Lamp Capsylite Designer 16 59034 Tungsten Ecologic Halogen Lamp Capsylite Designer 16 59031 Tungsten Ecologic Halogen Lamp
Tungsten bulb, 12 degree beam. 5-5/16" overall length. 2175 lumens, 120 volts. Medium base bulb. Tungsten halogen bulb replaces the regular R20 reflectors with halogen technology. 30 degree beam angle. 2,000 average life hours. 3-1/8" overall length. Boxed. Medium base bulb. Tungsten halogen bulb replaces the regular R20 reflectors with halogen technology. 30 degree beam angle. 2,000 average life hours. 3-1/8" overall length. Boxed.
Osram Sylvania 16113 Halogen Lamp Feit 38PAR20/QFL/ES/2 Dimmable Halogen Lamp Feit BPQ50MR16/GU10/3 Dimmable Halogen Lamp
Use indoor or out. 39 watts, 120 volts. 5.313" overall length. 30 degree beam angle. 2900K. 120 volt, boxed. Helps save energy compared to standard halogen bulb by adding Xenon gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, 530 lumens, medium E26 base. Instant on to full brightness, dimmable. Compact and dimmable. Carded.
Capsylite 16730 Tungsten Halogen Lamp Capsylite 16744 Halogen Lamp Capsylite 16583 Tungsten Double Life Halogen Lamp
Averages 3,000 life hours. 5.313" overall length. 25 degree beam angle. Use indoor or out. PAR-38, 120 volt, boxed Averages 3,000 life hours. 5.313" overall length. 25 degree beam angle. Use indoor or out. PAR-38, 120 volt, boxed Halogen narrow flood, 850 approximate lumens, 3000 average rated life hours. E26 reflector lamp, 25 degree beam angle, 2825K, 100CRI, 5.313" length, 4.752" diameter.
Feit 35PAR38/QFL/ES/2 Dimmable Halogen Lamp Feit 55PAR38/QFL/ES/2 Dimmable Halogen Lamp Feit 70PAR38/QFL/ES/2 Dimmable Halogen Lamp
Helps save energy compared to standard halogen bulb by adding XENON gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, 580 lumens, medium E26 base. Instant on to full brightness, dimmable. 5" height x 4.75" depth. Helps save energy compared to standard halogen bulb by adding XENON gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, medium E26 base. Instant on to full brightness, dimmable. Helps save energy compared to standard halogen bulb by adding XENON gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, medium E26 base. Instant on to full brightness, dimmable.
Feit 35PAR30/L/QFL/ES/ Dimmable Halogen Lamp Feit 55PAR30/L/QFL/ES/ Dimmable Halogen Lamp Feit 60PAR16/QFL-130 Dimmable Halogen Lamp
Helps save energy compared to standard halogen bulb by adding Xenon gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, 560 lumens, medium E26 base. Instant on to full brightness, dimmable. 50 watt equivalent. Helps save energy compared to standard halogen bulb by adding XENON gas and enhancing the pressure of the capsule. Has the same light output and characteristics as standard incandescent light bulbs. 1,000 hours average life, 3000K, medium E26 base. Instant on to full brightness, dimmable. Used for track lighting. Beam spread 20 degrees. Medium (E26) base. 2,500 hours, 3,000K, 2.875" MOL.
Capsylite 16739 Halogen Lamp Square D QO2L30SC Load Center Homeline Square D HOM24L70S Load Center
Averages 3,000 life hours. 5.313" overall length. 25 degree beam angle. Use indoor or out. PAR-38, 120 volt, boxed Main lug load center, indoor, 30 amp, 2 spaces/2 circuits. Accommodates both overhead and underground feed applications. 1" maximum knockout on the top and bottom of the enclosure. Comes with a doorless surface mount cover and factory installed main lugs. UL Listed. Main lug indoor load center, 70 amp, 2 spaces/4 circuits. Maximum SCCR of 10,000 and a maximum load of 240 volts. NEMA type 1 enclosure. Expandable loadcentre capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian HomeLine breakers.
Homeline Square D HOM24L70F Load Center Eaton BR24L70SP Load Center Eaton BR24L70FP Load Center
Main lug indoor load center, 70 amp, 2 spaces/4-circuits. NEMA type 1 enclosure with a flush mount cover. Overhead or underground feeds with 1-1/4" knockouts in both the top and bottom endwalls. Compatible with Homeline 1 pole and tandem breakers and a PK3GTA1 ground bar kit (not included). UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt. No.GBK5 or GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Single phase, 3 wire, insulated/bondable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. No. GBK5 or No. GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741.
PowerMark Gold TL412C Standard Load Center Cutler Hammer BRL200 Main Lug Kit Eaton CH2L70SP Load Center
Single-phase, three-wire, 120/240 volt AC. (4) 1" circuits or (8) 1/2" circuits. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 10,000 AIC. 40 - 225 amp single phase devices have removable closing caps. TL load center enclosures are galvanized steel. 7-1/4" x 9" x 3". UL Listed. Two pole - 200 amp - pair. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 2 (3/4") spaces, 4 poles with CHNT breakers, 120/240 volt. Ground bar No. GBK5 or No. GBK520 sold separately. Solid copper bus bar and branch fingers. In service entrance application, where neutral is bonded, unused neutral connections may be used for termination of equipment grounds. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. #14 - 2 main lug wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box - 4-1/2" 9-1/2" x 3-1/8". UL Listed file E8741.
Murray LC004NSU Load Center Square D QO24L70S Load Center Eaton BR48L125FP Load Center
Single phase - 3 wire; 120/240 volt;  8 circuits maximum with 4 - 1" spaces. 14" length x 8-1/2" width x 3-1/4" depth. 10,000 AIC. UL listed. Main lug load center, intended for fixed applications. 70 amp, 2 spaces/4 circuits. Surface mount cover with door and a NEMA type 1 enclosure for indoor use. Single phase unit, features a copper bus for conductivity and is rated for up to 10,000 SCCR. ANSI Certified and UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No.GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741.
PowerMark Gold TLM612FCUD Standard Convertible Load Center Eaton BR48L125SP Load Center Homeline Square D HOM612L100S Load Center
Indoor flush or surface mount with door. Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main  breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (6)  1" circuits or (12)  1/2"  circuits. 12-5/8" x 12-3/8" x 3-3/8". UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No. GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Main lug indoor load center, 100 amp,  6 space/12 circuit. NEMA type 1 enclosure.  Single phase, 3 wire, solid neutral. Expandable loadcentre capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian HomeLine breakers.
Homeline Square D HOM612L100F Load Center Eaton BR24L70RP Load Center Siemens E0204ML1060SU Load Center
Main lug indoor load center, 100 amp, 6 space/12 circuit. 1-1/2" knockouts in the top and bottom end walls to allow for use with either overhead or underground fed electrical wiring. 22,000 short circuit current rating (SCCR) and can be fitted with a secondary surge arrestor (not included) for added protection. Single phase, 3 wire, solid neutral. UL Listed. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Style 5R box. Single phase, 3 wire, solid neutral, 2 spaces and 4 circuits maximum 1-pole, 1 QP breaker maximum 2-pole, 120/240 volt AC. 10,000 AIR. One piece plated aluminum bus bar, heavier main bus for cooler operation, direct cable connection to bus bar. Main lugs and neutral on same plane, same drive tool. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Simple upper pan adjustment after trim is installed for flush leveling. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. UL Listed, complies fully with NEC and UL requirements for Class CTL. 5-1/8" x 9-7/8" x 2-5/8".
Eaton BR612L125FDP Load Center Siemens E0408ML1125SU Load Center Square D QO612L100SCP Load Center
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 volt. Furnished with door; No. GBK10 ground bar sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. Number 14 - number 1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 4 spaces and 8 circuits maximum 1-pole, 2 QP breakers maximum 2-pole, 120/240 volt. 10,000 AIR. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 amp maximum) is back-fed in a branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. 6-5/8" x 12-5/8" x 3-1/2". UL Listed, complies fully with NEC and UL requirements for Class CTL. Main lug indoor load center, 100 amp, 6 spaces/12 circuits. 1-1/2" maximum knockouts in the top and bottom end walls for overhead or underground feed. NEMA type 1 for indoor use. Steel enclosure. Single phase, solid neutral. UL Listed.
Square D QO612L100FCP Load Center Homeline Square D HOM24L70RB Load Center Feit BPQ150T3/CL/S Dimmable Short Halogen Lamp
Main lug indoor load center, 100 amp, 6 space/12 circuit, intended for use in fixed applications. NEMA type 1 enclosure and a copper bus bar for conductivity. Single-phase, rated for up to 240 volts and has a 10,000 maximum SCCR. UL Listed. Main lug outdoor load center, 70 amp, 2 space and 4 circuit. NEMA type-3R enclosure with a rainproof cover for outdoor use. Class 1170 unit is intended for use in fixed applications and can accommodate overhead or underground feed. Maximum SCCR of 10,000. ANSI Certified and UL Listed. Bright, white light for halogen flood lamps, floor lamps and worklights. 2,000 average life hours. 3-1/8" overall length, 120 volt.
Eaton BR816L125FP Load Center Eaton BR612L125RP Load Center Murray LW002GRU Load Center
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 poles, 120/240 volt. No.GBK10 ground bar and door sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14 - #1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 6 (1") spaces, 12 poles, 120/240 volt AC. With closure plates, hubs and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Style 7R box 11" x 13" x 3-9/16". UL Listed file E8741. Single phase - 3 wire; 120/240 volt;  4 circuits maximum;  2 - 1" spaces ; 10,000 AIC. 9-1/4" x 6-5/8" x 3-3/8". UL Listed.
PowerMark Gold TL270RCUP Standard Load Center PowerMark Gold TL240RCU Standard Load Center PowerMark Gold TLM812SCUDP Standard Convertible Load Center
One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100-percent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. (2) 1" or (4 )1/2" spaces; 22,000 AIC. Single-phase, three-wire, 120/240 Volt AC. 7-1/4" x 10" x 3-3/4". Single-phase, three-wire, 120/240 volt AC. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE 1/2" THQP. (2) 1" or (4) 1/2"  spaces; 22,000 AIC. 7-1/4" x 10" x 3-31/4". Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (8) 1" circuits or (16) 1/2" circuits. 11-9/16" x 11-3/8" x 3-3/8". UL Listed.
Eaton BR816L125SDP Load Center Feit BPQ500T3/CL Dimmable Halogen Lamp Eaton BR48L125RP Load Center
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 poles, 120/240 volt. Furnished with door. Ground bar No.GBK10 sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting or appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Bright, white light for halogen flood lamps, floor lamps and worklights. 2,000 average life hours; 4,000 hours for 130 volt lamps used on a 120 volt line. 4-11/16" overall length. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 4 (1") spaces, 8 poles, 120/240  volt AC. With closure plates, hubs, and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-1/0 wire range. Electrostatic powder coat, baked urethane painted. Style 7R box 11" x 13" x 3-9/16". UL Listed file E8741.
PowerMark TPL412RP Standard Load Center Eaton BR612L125SP Load Center Murray LW004NRU Load Center
One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. (4) 1" or (8)  1/2"  spaces; 10kAIC. Single-phase, Three-wire, 120/240 volt AC. 7-1/2" x 9-7/32" x 3-5/16". Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 volt. No.GBK10 ground bar and door sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance appliance. #14 - #1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Convertible to main breaker using double pole breaker. 2 full spaces. 4 space, 8 circuit, combination mount.
Siemens EQ W0204ML1060U Load Center Eaton BR24L125RP Enclosed Load Center Capsylite 16740 Tungsten Ecologic Halogen Lamp
Single phase, 3 wire, solid neutral, 2 spaces and 4 circuits maximum 1-pole, 1 QP breaker maximum 2-pole, 120/240 volt AC. 10,000 AIR. With closure plates, HS style hubs sold separately, uses ECHA075 (694.3559) Hub. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Will not accommodate 2-pole GFCI or circuit breaker with shunt trip. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and UL Listed, complies fully with NEC and UL requirements for Class CTL. 5" x 8" x 4-1/4". Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-1/0 wire range. Electrostatic powder coat, baked urethane painted. Style 6R box 6-7/8" x 12" x 4-1/2". UL Listed file E8741. Tungsten bulb, 1,500 average life hours. 1070 lumens, 2900K. 25 degree beam angle. 5.313" overall length. PAR-38, 120 volt, boxed.
PowerMark Gold TLM812FCUD Standard Convertible Load Center Siemens EQ W0408ML1125U Load Center LOAD CENTR 125A 8SP 16C INDOOR
Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (8) 1" circuits or (16) 1/2" circuits. 12-5/8" x 12-3/8" 3-3/8". UL Listed. Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 4 spaces/8 circuits 1-pole, 2 QP breakers 2-pole, 120/240 volt AC. 10,000 AIR. With closure plates, HS-hubs sold separately. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 amp maximum) is back-fed in a branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and UL Listed, complies fully with NEC and UL requirements for Class CTL. 6" x 12-1/4" x 4-1/4". Value kit, indoor. Includes a sturdy highly-conductive tin-plated copper buss bar and a rust-resistant galvanized box. Indoor NEMA 1 enclosure with combination surface/flush front. Factory-installed main lug, full-length neutral bars, top or bottom feed and self-adjusting, dead-front cover. One-piece interior removes and re-installs easily. Single-phase, 3-wire, 120/240-volt and 22K AIC rating. All holes are rated for 14-4 wire and 100 percent rated split neutrals on each side. Accepts Q-Line THQL standard, GFCI and AFCI circuit breakers, including GE's exclusive 1/2" THQPs. UL Listed and ANSI Certified. 16" height x 14" width x 3.375" depth, 16.79 lb.
Feit BPEXN-120 Dimmable Halogen Lamp Murray LC008DSU Load Center Feit BPQ35MR16/GU10 Dimmable Halogen Lamp
Open reflector provides a bright, white light for track lighting. 38 degree beam spread. 3,000 average life hours. 1-7/8" overall length. Carded. Single phase type 1 with 8-1" spaces, 16 circuits. Use neutral lug kit DLK1 or DLK2 as required. Indoor closure with door. Compact and dimmable. Carded.
Square D HOM816L125PC Homeline Main Lug Load Center GE TL412R1P Standard Load Center Eaton CH2L70RP Load Center
Main lug indoor load center. Convertible to a main breaker with a QOM1 main breaker. Single-phase load center, NEMA type 1 enclosure, combination flush/surface indoor cover. Overhead or underground feed options. Plated aluminum bus bar. UL Listed. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. (4) 1" or (8) 1/2"  spaces. Single-phase, three-wire, 120/240 Volt AC. 7-1/4" x 10" x 3-3/4". Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 2 (3/4") spaces, 4 poles with CHNT breakers, 120/240 volt AC. With closure plates, hubs and ground bar No.GBK5 or No.GBK520 sold separately. Copper bus bar. In service entrance application, where neutral is bonded, unused neutral connections may be used for termination of equipment grounds. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. #14 - 2 main lug wire range. Electrostatic powder coated. Style 5R box 4-1/2" x 9-1/2" x 3-1/8". UL Listed file E8741.
PowerMark Gold TLM1212CCU Standard Convertible Load Center Square D QO24L70RB Load Center Homeline Square D HOM612L100RB Load Center
Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main  breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. 14 spaces, 24 circuits. 14-1/8" x 16-1/8" x 3-3/8". UL Listed. Main lug indoor load center, 70 amp, 2 spaces/4 circuits. Intended for overhead or underground feed. 1-1/4" maximum knockouts in the top and bottom end walls. NEMA 3R enclosure for outdoor use with a factory included cover. Copper bus for conductivity. UL Listed. Outdoor main lug load center, 100 amp, 6 space and 12 circuits. Can be wired for underground or overhead feeds with a 2-1/2" hub on the top and a 1-1/2" knockout on the bottom. NEMA type 3R enclosure resists rain for durable performance. ANSI Certified and UL Listed.
Feit BPQ50MR16/GU10 Tamper Resistant Halogen Lamp PowerMark Gold TLM612RCU Standard Convertible Load Center HomeLine HOM115GFICP GFCI Circuit Breaker
Compact and dimmable. Carded. Single-phase, Three-wire, 120/240 volt AC. Convertible. Full-length neutrals are easier to wire, reducing installation time and cost. Removable closing cap. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. UL listed. 11-1/4" x 11-1/8" x 3-1/4". GFCI circuit breaker offers protection of entire branch circuits where damp-location shock hazards may exist, as well as Class A overload and short-circuit protection. Class A denotes a GFCI that will trip when a fault current to ground is 5 milliamperes or more. Yellow push to test button. CSA approved. Rated 10,000 AIR and 120/240 VAC.
HomeLine HOM120GFICP GFCI Circuit Breaker LOAD CENTER 125A 8SPACE 16CIR Square D QO612L100RBCP Load Center
GFCI circuit breaker offers protection of entire branch circuits where damp-location shock hazards may exist, as well as Class A overload and short-circuit protection. Class A denotes a GFCI that will trip when a fault current to ground is 5 milliamperes or more. Yellow push to test button. CSA approved. Rated 10,000 AIR and 120/240 VAC. Single-phase, Three-wire, 120/240 volt AC. Convertible. Full-length neutrals are easier to wire, reducing installation time and cost. Removable closing cap. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. UL listed. 11-1/4" x 11-1/8" x 3-1/4". Outdoor main lug load center, 100 amp, 6 space 12 circuit. NEMA type 3R enclosure with a rainproof cover. Copper bus bar, accommodates standard QO or QO tandem circuit breakers. ANSI Certified and UL Listed.
Square D QO816L100FCP Load Center Square D QO816L100SCP Load Center Siemens E0816ML1125S Load Center
Main lug indoor load center, 100 amp, 8 space/16 circuit. 1-1/2" maximum knockouts in the top and bottom end walls to accommodate overhead or underground feed. The center is rated for a maximum load of 240 volts and has a 10,000 SCCR. NEMA type 1. Copper bus for conductivity. Single phase, 3 wire, solid neutral. UL Listed. Main lug indoor load center, 100 amp, 8 spaces/16 circuits. 1-1/2" maximum knockouts in the top and bottom end walls to accommodate overhead or underground feed. Maximum load of 240 volts and a 10,000 SCCR. NEMA type 1. Copper bus for conductivity. Single phase, 3 wire, solid neutral. UL Listed. Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 8 spaces and 16 circuits maximum 1-pole, 4 QP breakers maximum 2-pole, 120/240 volt. 10,000 AIR. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service entrance equipment when a main breaker (125 amp maximum) is back-fed in branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. 12-3/8" x 14-3/4" x 3-7/8". UL Listed, complies fully with NEC and UL requirements for Class CTL.
Siemens ES S1224L1125 Load Center Eaton BR816L125RP Load Center BULB 90W PAR38 HAL RED
Single phase, 3 wire, Rated 100,000A IR. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when not more than six main disconnecting means are provided. 12 spaces, 24 circuits maximum. 18" height x 14-1/4" wide by 3-7/8" deep. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 8 (1") spaces, 16 poles, 120/240 volt AC. With closure plates, hubs and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Style 7R box 11" x 13" x 3-9/16". UL Listed file E8741. Hardglass reflector lamp. Medium E26 skirt base. 90 watt, 120 volt flood. 2500 hours average life. PAR 38 bulb, 30 degree beam angle.
BULB 90W PAR38 HAL AMBER      BULB 90W PAR38 HAL BLUE       BULB 90W PAR38 HAL GREEN
Hardglass reflector lamp. Medium E26 skirt base. 90 watt, 120 volt flood. 2500 hours average life. PAR 38 bulb, 30 degree beam angle. Hardglass reflector lamp. Medium E26 skirt base. 90 watt, 120 volt flood. 2500 hours average life. PAR 38 bulb, 30 degree beam angle. Hardglass reflector lamp. Medium E26 skirt base. 90 watt, 120 volt flood. 2500 hours average life. PAR 38 bulb, 30 degree beam angle.
Feit BPQ300T3/CL/2 Dimmable Halogen Lamp BREAKER 15AMP GFCI SELF TEST  BREAKER 20AMP GFCI SELF TEST
Bright, white light for halogen flood lamps, floor lamps and worklights. 2,000 average life hours; 4,000 hours for 130 volt lamps used on a 120 volt line. 4-11/16" overall length. Automatically senses hot wire-to-ground faults and shuts off the power. Auto-monitoring function provides periodic automatic testing of GFCI. If the self-test detects that GFCI protection might be compromised it indicates an alert.10 kAIC capacity. Automatically senses hot wire-to-ground faults and shuts off the power. Auto-monitoring function provides periodic automatic testing of GFCI. If the self-test detects that GFCI protection might be compromised it indicates an alert.10 kAIC capacity.
GFCI INTERUPTER 15AMP 1POLE   GFCI INTERUPTER 20AMP 1POLE   GFCI INTERUPTER 30AMP 1POLE
Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 4.5" height x 1.25" width x 3" depth, .479 lb. Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 4.5" height x 1.25" width x 3" depth, .479 lb. Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 4.5" height x 1.25" width x 3" depth, .479 lb.
Square D HOM2040L125PC Homeline Main Lug Load Center BRLC 125A 12/24CR AL BUS/WGB  Siemens EQ W0816ML1125CU Load Center
Main lug indoor load center. Convertible to a main breaker with a QOM1 main breaker. Single-phase load center, NEMA type 1 enclosure, combination flush/surface indoor cover. Overhead or underground feed options. Plated aluminum bus bar. UL Listed. BR style 1-inch loadcenter, main lug, ground bar, includes BREQS125 hold-down screw, 125A, single-phase, 24-pole, 24 circuits, 12 spaces, 120/240V, #6-2/0 AWG Cu/Al at 60 or 75 degreesC wire, NEMA 1 enclosure, b1 box size. Ground bar, includes BREQS125 hold-down screw. 10 kAIC interrupt rating. Aluminum bus, combination mounting. 3.88 in x 14.31 in x 16.75 in. Suitable for use as service equipment when no more than 6 main disconnecting means are provided or when not used as lighting and appliance panelboard. Has notch for brhdk125 hold-down kit. Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 8 spaces/16 circuits 1-pole, 4 QP breakers 2-pole, 120/240 volt AC. 10,000 AIR. HS-hubs sold separately. One piece copper bus bar, 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (125 amp maximum) is back-fed in a branch position, and used with main breaker retainer clip No. MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. UL Listed, complies fully with NEC and UL requirements for Class CTL. 12-1/8" x 14-3/4" x 4-1/4".
Square D HOM816L125PRB Homeline Main Lug Load Center Feit BPQ50MR16/FL Non-Ground  Halogen Lamp Feit BPQ35MR16/FL Dimmable Halogen Lamp
Main lug outdoor load center, 125 amp 8 space/16 circuit. Convertible to a main breaker. Single-phase load center. Overhead or underground feed options. Plated aluminum bus bar. UL Listed. Compact and dimmable, 2500 average life hours. Fits in regular sockets. 2-3/4" overall length. 120 volt, carded. Compact and dimmable, 2500 average life hours. Fits in regular sockets. 2-3/4" overall length. 120 volt, carded.
MES MP120GF Type MP-T GFCI Circuit Breaker MES QF120 GFCI Miniature Circuit Breaker Square D HOM2040M100PC Homeline Main Breaker Load Center
Protects against shock hazard where water and electricity are present. 120 / 240 volts. UL listed. 1 pole, 1" wide. For use on circuits where contact with water or another ground is possible while using an electrical device. 120 volt, 1 pole circuit breakers. Built with a plated, aluminum bus bar. Main breaker installed. UL Listed.
Square D QO124L125PGC QO Main Lug Load Center Eaton BR1220B100 Load Center Siemens E1020MB1100FCGP Remodel Load Center
Convertible to a main breaker with a QOM1 main breaker. Single-phase load center, NEMA type 1 enclosure,  combination flush/surface indoor cover. Overhead or underground feed options. Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 12 (1") spaces, 20 poles, 120/240 volt.  Main breaker type BR at 10,000 AIR. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. 14-5/16" x 18-3/4" x 3-7/8". UL Listed file E52977. Single phase, 3 wire, 10 spaces/20 circuits, 120/040 volt. 22,000 AIR. Use for older home renovation projects where the distance between the studs are narrower then current construction practices. One piece bus bar construction designed for use only with circuit breakers. Simple dead front adjustment after trim is installed. Positive load side circuit breaker hook rails. Two 15 amp single pole and one 30 amp double pole breakers included. 14-3/4" x 12-3/8"  3-7/8". UL Listed.
Square D QO120GFICP Type QO GFCI Circuit Breaker Square D QO115GFICP Type QO GFCI Miniature Circuit Breaker Square D QO130GFI Type QO GFCI Circuit Breaker
Intended for protection of entire branch circuits where damp-location shock hazards may exist. The unit features a thermal-magnetic tripping mechanism with a red Visi-Trip indicator to identify a tripped breaker. 120 volt, 10,000 AIR. 1 space per breaker. CSA approved Canadian Square D QO loadcentre. Intended for protection of entire branch circuits where damp-location shock hazards may exist. The unit features a thermal-magnetic tripping mechanism with a red Visi-Trip indicator to identify a tripped breaker. 120 volt, 10,000 AIR. 1 space per breaker. CSA approved Canadian Square D QO loadcentre. Intended for protection of entire branch circuits where damp-location shock hazards may exist. The unit features a thermal-magnetic tripping mechanism with a red Visi-Trip indicator to identify a tripped breaker. 120 volt, 10,000 AIR. 1 space per breaker. CSA approved Canadian Square D QO loadcentre.
Square D HOM1224M100PC Homeline Main Breaker Load Center Square D QO816L100RBCP Load Center PowerMark Gold TLM1212RCUP Standard Convertible Load Center
Built with a plated, aluminum bus bar. Main breaker installed. UL Listed. Main lug outdoor load center, 100 amp, 8 space/16 circuit, has a 2-1/2" maximum type B hub in the top end wall, a 1-1/2" maximum knockout in the bottom end wall and a B-cap covering on the 2" bushed opening. NEMA type 3R enclosure with a rainproof cover for outdoor use. ANSI Certified and UL Listed. Factory installed main lug, convertible to a main breaker. Single-phase, three-wire, 120/240 volt AC. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 per cent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. 100-225 amp devices have removable closing cap. (12) 1" or (24) 1/2"  spaces; 22000 AIC. 12-1/2" x 21-3/16" x 4-5/8".
Speedfax S1224B1100 Convertible Load Center BREAKER CH 15AMP GFCI SELFTEST BREAKER CH 20AMP GFCI SELFTEST
Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth. Automatically senses hot wire-to-ground faults and shuts off the power. Auto-monitoring function provides periodic automatic testing of GFCI. If the self-test detects that GFCI protection might be compromised it indicates an alert.10 kAIC capacity. Automatically senses hot wire-to-ground faults and shuts off the power. Auto-monitoring function provides periodic automatic testing of GFCI. If the self-test detects that GFCI protection might be compromised it indicates an alert.10 kAIC capacity.
PowerMark Gold TM1210CCU Standard Load Center PowerMark Gold TM2010CCU Standard Load Center Speedfax S2020B1100 Convertible Load Center
Single-phase, Three-wire, 120/240 volt AC. (12) 1" circuits or (24) 1/2" circuits. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 100-225 amp devices have removable closing cap. 22,000 AIC. 14" x 19" x 3-3/4". UL Listed. Single-phase, three-wire, 120/240 volt AC. (20) 1" spaces. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson  screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. 100-225 amp devices have removable closing cap. 22,000 AIC. 14" x 23" x 3-3/4". UL Listed. Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth.
Square D HOM2040M100PCVP Homeline Main Breaker Load Center Square D QO Circuit Breaker Enclosure BRLC 125A 20/40CR AL BUS/WGB
Built with a plated, aluminum bus bar. Main breaker installed. UL Listed. QO 100 amp, outdoor, NEMA type-3R circuit breaker enclosure, accepts QO circuit breakers with factory installed accessories. Solid neutral and ground bar kit PGTA2 included. 120/240 Vac, 22,000 maximum short circuit current rating that is not for use with single pole QO breakers. UL Listed. Type BR single-phase, main lug loadcenters. Three-wire 120/240 Vac. Insulated/bondable split neutral, 20 spaces, 24 circuits, indoor, c1 box size. Has notch for BREQS125 hold-down kit. Combination cover style. Ground bar GBK1220 installed.
LOAD CENTER 100A 1P3W 120/240V Speedfax S2040B1200 Convertible Load Center Murray W0204MB1100 Load Center
Value kit, indoor. Includes a sturdy highly-conductive tin-plated copper buss bar and a rust-resistant galvanized box. Indoor NEMA 1 enclosure with combination surface/flush front. Factory-installed main lug, full-length neutral bars, top or bottom feed and self-adjusting, dead-front cover. One-piece interior removes and re-installs easily. Single-phase, 3-wire, 120/240-volt and 22K AIC rating. All holes are rated for 14-4 wire and 100 percent rated split neutrals on each side. Accepts Q-Line THQL standard, GFCI and AFCI circuit breakers, including GE's exclusive 1/2" THQPs. UL Listed and ANSI Certified. 16" height x 14" width x 3.375" depth, 16.79 lb. Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth. Single phase, 2 spaces/4 circuits, 120/240 volt. 10,000 AIR. Factory installed main breaker. Additional spaces allow connection of external circuits such as yard lights. One 1-1/4" HS125 hub included. Normally used as a means of disconnecting power to a mobile home panel, but also used as a disconnect for houses. Aluminum bus bar insulates and secures interior. Gray enamel finish. Pole mountable. UL Listed for use as service entrance equipment.
Murray LC2040B1100 Rock Solid Load Center BRLC 100A MN 20/40 CR         Murray LW102NLU Load Center
Main breaker load center. 100 amp Single phase, 3 wire, split neutral, 20 spaces/40 circuits. 120/240 volt. Indoor with combination surface/flush cover. 22,000 AIC rating. Aluminum bus bar. One piece steel interior allows for easy removal. Keyhole and nail slots provide easy enclosure mounting. Knockout patterns sized for maximum wiring flexibility. UL Listed. BR style 1-inch loadcenter, main circuit breaker, no feed-thru lugs, 100A, single-phase, 40-pole, 40 circuits, 20 spaces, 120/240V, #4-1/0 AWG Cu/Al at 60 or 75 degreesC wire, Three-wire, NEMA 1 enclosure, d1 box size. Interrupt Rating 25 kAIC. Aluminum bus. Combination mounting. 5.19 in x 14.31 in x 25 in. UL 50, UL 67. Cover included. Single phase, 2 spaces/4 circuits, 120/240 volt. 10,000 AIR. Factory installed main breaker. Additional spaces allow connection of external circuits such as yard lights. One 1-1/4" HS125 hub included. Normally used as a means of disconnecting power to a mobile home panel, but also used as a disconnect for houses. Aluminum bus bar insulates and secures interior. Gray enamel finish. Pole mountable. 12-1/2" height x 6" width x 4-1/4" depth. UL Listed for use as service entrance equipment.
LOAD CENTR 125A 12SPACE 24CIR Square D QO112M100C Load Center BULB 90W PAR38 HAL NIGHTCHASER
Value kit, indoor. Includes a sturdy highly-conductive tin-plated copper buss bar and a rust-resistant galvanized box. Indoor NEMA 1 enclosure with combination surface/flush front. Factory-installed main lug, full-length neutral bars, top or bottom feed and self-adjusting, dead-front cover. One-piece interior removes and re-installs easily. Single-phase, 3-wire, 120/240-volt and 22K AIC rating. All holes are rated for 14-4 wire and 100 percent rated split neutrals on each side. Accepts Q-Line THQL standard, GFCI and AFCI circuit breakers, including GE's exclusive 1/2" THQPs. UL Listed and ANSI Certified. 16" height x 14" width x 3.375" depth, 16.79 lb. Welded sheet steel. Single phase, 3 wire, split neutral, 12 spaces/12 circuit, 120/240 volt. 22,000 AIR factory installed main breaker. Comes with a ground bar and a combination cover for added protection. Shielded copper bus bar. 2-1/2" knockouts located on the top and bottom. Accepts QO circuit breakers and is compatible with overhead and underground service feeds. UL Listed. High lumen, 1,000 hours average life, 1790 lumens, Par38, 2950K, medium base 90 watt replaces 250 watt.
BRLC 200A 20/40 CR ALBUS/WGB  MES QF250 GFCI Miniature Circuit Breaker Square D HOM2040M200PC Homeline Main Breaker Load Center
BR style 1-inch loadcenter, main lug, ground bar, includes BREQS125 hold-down screw, 200A, single-phase, 40-pole, 40 circuits, 20 spaces, 120/240V, #1-300 kcmil Cu/Al at 60 degreesC or 75 degreesC wire, three-wire NEMA 1 enclosure, c2 box size. Cover included. 3.88 in x 14.31 in x 23 in. Has notch for brhdk125 hold-down kit. Non-interchangeable trip. GFCI breakers are ideally suited for the protection of hot tubs, spas and other large loads requiring GFCI protection. 120/240 volt. Built with a plated, aluminum bus bar. Main breaker installed. UL Listed.
Eaton BR1224L200R Load Center GFCI INTERUPTER 30AMP 2POLE   LOADCENTER 100A 20/40 VP
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 12 (1") spaces 24 poles, 120/240 volt AC. Has notch for No.BRHDK125 hold down kit. With closure plates, hubs and ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 6 main disconnecting means are provided and when not used as lighting and appliance panelboard. Twin neutral with non-removable cross bus. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #1 - 300 kcmil wire. Electrostatic powder coat, baked urethane painted. B2R box 14-5/16" x 18-3/4" x 5-3/16". UL Listed file E52977. Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 3" height x 2.25" width x 4.5" depth, .858 lb. BR style 1-inch loadcenter, main circuit breaker, value pack, 100A, single-phase, 40-pole, 40 circuits, 20 spaces, 120/240V. Wire size #4-1/0 AWG Cu/Al at 60 or 75 degreesC, NEMA 1 enclosure, d1 box size. Aluminum bus, combination mounting. 3.88 in x 14.31 in x 18.75 in. Includes 6-br120. Cover included.
Speedfax S3040B1200 Convertible Load Center Square D HOM3060M200PC Homeline Main Breaker Load Center Eaton BR1020B100RF Load Center
Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth. Built with a plated, aluminum bus bar. Main breaker installed. UL Listed. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 10 (1") spaces, 20 poles, 120/240 volt AC. Main breaker type BR at 10,000 AIC. Includes feed thru lugs for both phase and neutral conductors. With hub closure plates, hubs and ground bar kit (necessary for sub-feeding) sold separately. Tin plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. 14-5/16" x 18-3/4" x 5-3/16". UL Listed file E52977.
Square D HOM3060M200PCVP Homeline Main Breaker Load Center HomeLine HOM250GFICP GFCI Standard Circuit Breaker Siemens ES S3030B1150 Convertible Load Center
Built with a plated, aluminum bus bar. Main breaker installed. UL Listed. GFCI circuit breaker offers protection of entire branch circuits where damp-location shock hazards may exist, as well as Class A overload and short-circuit protection. Class A denotes a GFCI that will trip when a fault current to ground is 5 milliamperes or more. Yellow push to test button. CSA approved. Rated 10,000 AIR and 120/240 VAC. Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth.
BR SPA 50A ST   GFI           PowerMark Gold TM2020CCUP Load Center TBR 1GFI ST BKR 20A2P 120/20V
Spa panel, wire size - number 8-2 Cu/Al. 60 or 75 degreesC. NEMA 3R enclosure. Box size - 5R. Includes factory installed breaker, ground-fault self test. 10.2 In X 4.9 In X 4.3 In, 4.45 lb. UL Listed. Single-phase, three-wire, 120/240 volt AC. (20) 1", (40) 1/2" spaces. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 100-225 amp devices have removable closing cap. 22,000 AIC. 14" x 28-7/16" x 3-3/4". UL Listed. GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375.
TBR 1GFI ST BKR 30A2P 120/20V TBR 1GFI ST BKR 50A2P 120/20V Eaton BR2040B200 Load Center
GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375. GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375. Steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 20 (1") spaces, 40 circuits, 120/240 volt. Main breaker type BWH at 25,000 AIC. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. Number 2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. UL Listed file E52977. 14-5/16" width x 29-1/8" height x 3-7/8" depth.
Square D HOM816M200PFTRB Hom Main Breaker Load Center Midwest UG412RMW250 Spa Panel PowerMark Gold TM820RCUFLP Load Center
Single phase, 3 wire, insulated/bonded split neutral. 200 amp, 8 spaces/16 circuits maximum. 120/240 volt AC. 10,000 AIR. For mobile homes and farm applications. Overhead or underground feeds and offers feed-thru lugs. Plated aluminum bus bar. Has a 22,000 maximum short circuit current rating. Provided equipment: circuit breaker [space(1) 2P 200 amp 120/240 volt AC main supply ready assembled and grounding bar [space(1) ready assembled. UL Listed. Single phase, 2 or 4 breaker spaces. 50 amp GFI protection rating. Moisture resistant use around water heaters, swimming pools, spas, hot tubs, garden tubs, pools, etc. Includes 2 pole 50 amp ground fault breaker. Factory Installed main breaker. Single phase, three wire, 120/240 volt AC. (8) 1" or (16) 1/2" spaces; 22,000 AIC. One piece interior removes and reinstalls easily. Full length neutrals are easier to wire, reducing installation time and cost. Minimum 100 per cent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q L