Cooper 270B Grounded  Duplex Receptacle Cooper 270W Grounded  Duplex Receptacle Cooper 270V Grounded  Duplex Receptacle
Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements.
RECEPTACLE DUPLEX 15A 125V LA Cooper TR270W  Tamper Resistant Duplex Receptacle Cooper TR270V  Tamper Resistant Duplex Receptacle
Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed.
Cooper TR270V Tamper Resistant Duplex Receptacle Cooper TR270W Tamper Resistant Duplex Receptacle RECEPTACLE DUPLEX LIGHT ALMOND
Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed.
Despard K1I 1-Hole Standard Wall Plate Despard K3I 3-Hole Standard Wall Plate Despard K2I 2-Hole Standard Wall Plate
Switch plate with horizontal one opening, two opening and three opening sizes. Older style device with a rounded shape that is slightly flattened top and bottom. Interchangeable, supplied with mounting straps. Flexible, smaller than a standard duplex receptacle device, fits in a smaller opening. Used in locations with limited space or restricted options. Openings are 11/16" high x 29/32" wide. UL Listed, CSA Certified. Switch plate with horizontal one opening, two opening and three opening sizes. Older style device with a rounded shape that is slightly flattened top and bottom. Interchangeable, supplied with mounting straps. Flexible, smaller than a standard duplex receptacle device, fits in a smaller opening. Used in locations with limited space or restricted options. Openings are 11/16" high x 29/32" wide. UL Listed, CSA Certified. Switch plate with horizontal one opening, two opening and three opening sizes. Older style device with a rounded shape that is slightly flattened top and bottom. Interchangeable, supplied with mounting straps. Flexible, smaller than a standard duplex receptacle device, fits in a smaller opening. Used in locations with limited space or restricted options. Openings are 11/16" high x 29/32" wide. UL Listed, CSA Certified.
Cooper 736B-BOX  Duplex Receptacle Cooper 736V-BOX  Duplex Receptacle Cooper 736W-BOX  Duplex Receptacle
Standard contacts. Side wire terminals accept up to #12 wire. Terminal screws backed out, ready for wiring. 15 amp/125 volt. UL Listed. Standard contacts. Side wire terminals accept up to #12 wire. Terminal screws backed out, ready for wiring. 15 amp/125 volt. UL Listed. Standard contacts. Side wire terminals accept up to #12 wire. Terminal screws backed out, ready for wiring. 15 amp/125 volt. UL Listed.
Arrow Hart CR15B  Duplex Receptacle Arrow Hart CR15V  Duplex Receptacle Arrow Hart CR15W  Duplex Receptacle
Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed.
Cooper 1107V Decorator  Duplex Receptacle Cooper 1107W Grounded  Duplex Receptacle RECEPTACLE DECOR 2P 3W 15A LA
Longer, wider strap provides 40 percent more contact area to wall board. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire and wire looper for pre-looping. Combination slot/Phillips head mounting and terminal screws for installation with power screwdrivers. Terminal screws backed out - ready for wiring. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no. E15058), Fed. Specs. WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. Longer, wider strap provides 40 percent more contact area to wall board. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire and wire looper for pre-looping. Combination slot/Phillips head mounting and terminal screws for installation with power screwdrivers. Terminal screws backed out - ready for wiring. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no. E15058), Fed. Specs. WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed.
RECEPTACLE BULK LT ALMOND 20A Arrow Hart CR20W Grounded Duplex Receptacle Arrow Hart CR20V Grounded Duplex Receptacle
Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed.
Arrow Hart CR20B Grounded Duplex Receptacle Spot-Gro C270V Duplex  Electrical Receptacle Cooper C270W  Duplex Receptacle
Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements.
Cooper 1107-9BK Decorator  Duplex Receptacle RECEPTACLE DECO AG LT ALMOND  Arrow Hart BR15V  Duplex Receptacle
Terminal screws backed out-ready for wiring. Push-in terminals accept number 14 solid wire. Side wire terminals accept up to number 10 solid or stranded wire. Longer, wider strap provides 40 percent more contact area to wall board. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire to speed installation. Built-in wire looper for pre-looping. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no.E15058), Fed.Specs.WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. Terminal screws backed out-ready for wiring. Push-in terminals accept number 14 solid wire. Side wire terminals accept up to number 10 solid or stranded wire. Longer, wider strap provides 40 percent more contact area to wall board. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire to speed installation. Built-in wire looper for pre-looping. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no.E15058), Fed.Specs.WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed.
Arrow Hart BR15W  Duplex Receptacle Cooper TR1107W Decorative Tamper Resistant Duplex Receptacle Cooper TR1107V Decorative Tamper Resistant Duplex Receptacle
High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed.
AmerTac 2TPW Round Corner Wall Plate Cooper TR1107V Decorator Tamper Resistant Duplex Receptacle Cooper TR1107W Decorator Tamper Resistant Duplex Receptacle
With screws. 5" height x 2-3/4" width x 1/4" depth. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed.
AmerTac 935TAL Wall Plate AmerTac 935TW Rectangular Wall Plate Arrow Hart BR20V  Duplex Receptacle
With screws. 5" height x 2-3/4" width x 1/4" depth. With screws. 5" height x 2-3/4" width x 1/4" depth. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed.
Arrow Hart BR20W  Duplex Receptacle Arrow Hart BR20A  Duplex Receptacle Arrow Hart 1877  Single Receptacle
High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed. Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. Tamper resistant receptacles have a UL Listed shutter system. 20 amp, 125 volt.
Arrow Hart 1877  Single Receptacle Arrow Hart 1877W  Single Receptacle RECEPTACLE SGL LT ALMOND 125V
Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. Tamper resistant receptacles have a UL Listed shutter system. 20 amp, 125 volt. Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. Tamper resistant receptacles have a UL Listed shutter system. 20 amp, 125 volt. Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. Tamper resistant receptacles have a UL Listed shutter system. 20 amp, 125 volt.
Cooper 5270  Standard Duplex Receptacle Cooper 5270  Standard Duplex Receptacle RECEPTACLE COMM LT ALMOND 20A
Meets all UL 498 and 1567 requirements. Longer, wider strap provides 40 percent more contact area. Side wire terminals accept up to #10 solid or standard copper or aluminum wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. 15 amp, 125 volt. Bulk pack. Meets all UL 498 and 1567 requirements. Longer, wider strap provides 40 percent more contact area. Side wire terminals accept up to #10 solid or standard copper or aluminum wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. 15 amp, 125 volt. Bulk pack. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed.
Arrow Hart 817  Single Receptacle Cooper 827 Duplex Receptacle Cooper 827 Duplex Receptacle
Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. Tamper resistant receptacles have a UL Listed shutter system. cULus Listed. 15 amp, 125 volt. Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws.
Arrow Hart 817W  Single Receptacle Cooper 827 Duplex Receptacle Cooper TWR270W Tamper Resistant Weatherproof Duplex Receptacle
Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. Tamper resistant receptacles have a UL Listed shutter system. cULus Listed. 15 amp, 125 volt. Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws. Receptacle is residential grade, duplex, tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. TR and WR designations provide visual identification. UL, cULus listed. 15 amp, 125 volt.
Cooper TWR270V Tamper Resistant Weatherproof Duplex Receptacle Arrow Hart 816  Single Receptacle Arrow Hart 816  Single Receptacle
Receptacle is residential grade, duplex, tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. TR and WR designations provide visual identification. UL, cULus listed. 15 amp, 125 volt. Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. 15 amp, 250 volt. Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. 15 amp, 250 volt.
Cooper 877 Grounded Duplex Receptacle Cooper 877 Grounded Duplex Receptacle Atron 163TBR Square Corner Traditional Wall Plate
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws. Traditional square corner design. With screws.
Cooper 877 Grounded Duplex Receptacle AmerTac 161T Wall Plate Jandorf 61014 Single Electrical Receptacle
Meets all UL 498 requirements. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. 0.50" thick steel wrap-around mounting strap galvanized for corrosion resistance. Easy access split circuit break-off tab (except dual voltage). Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws. Traditional square corner design. With screws. 5" height x 2-7/8" width x 1/4" depth. Jandorf Electrical Receptacle, Single, 2 Poles, 2 Wires, 15 A, 125 V, Black, CSA Certified, For Indoor Use
Jandorf 61015 Single Electrical Receptacle Cooper A12 869-BOX  Duplex Receptacle Aspire 9505 Duplex Recessed Tamper Resistant Electrical Receptacle
Jandorf Electrical Receptacle, Single, 2 Poles, 2 Wires, 15 A, 125 V, White, CSA Certified, For Indoor Use Commercial specification grade straight blade receptacle on 4" galvanized steel cover. Back and side wire. 15 amp 125 volt. 5-15R NEMA. Temperature rating of -20 to 60 degrees C. UL Listed, meets all CSA requirements, NOM Certified. Receptacle is residential grade, duplex, tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. An oversized strap provides a solid base for mounting and virtually eliminates "floating" installations. Thermoplastic construction ultrasonically welded top and backbody; extra-long, extra-wide mounting straps; number 12 and number 14 push-in terminals; backwire clamps on side terminals; easy-access ground screws; built-in wire strippers. Meets all UL 498 requirements, (file no. E15058); CSA Certified, C22.2 no. 42 (file no. 6914 (6233-01); NOM Certified. Flammability rating: V2 per UL 94. temperature rating: -40 degrees C to 65 degrees C. TR designations provides visual identification. UL, cULus Listed. 15 amp, 125 volt.
RECEPT DUPLEX RB 15A 125V 2P3W Osram Sylvania 14070 Incandescent Lamp AmerTac 935TTW Wall Plate
Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed. Standard base incandescent. 120 volt. Averages 1,000 life hours. Tough shock resistant filament. 4-7/16" length. With screws. 5" height x 4-5/8" width x 1/4" depth.
Cooper C1507V Grounded Standard Duplex Receptacle Cooper C1507W Grounded Standard Duplex Receptacle Osram Sylvania 13001 Incandescent Lamp
With No. 1107 wall plate. UL Listed. 15 amp, 125 volt, grounded. Carded. With No. 1107 wall plate. UL Listed. 15 amp, 125 volt, grounded. Carded. Standard base incandescent. 120 volt. Averages 1,000 life hours. Tough shock resistant filament. 4-7/16" length.
Osram Sylvania 13002 Very High Output Incandescent Lamp Arrow Hart TR Duplex Receptacle Arrow Hart TR Duplex Receptacle
Standard base incandescent. 120 volt. Averages 1,000 life hours. Tough shock resistant filament. 4-7/16" length. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal Specifications WC-596. UL Listed. Tamper resistant receptacles have a UL Listed shutter system. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal Specifications WC-596. UL Listed. Tamper resistant receptacles have a UL Listed shutter system.
Arrow Hart 1876  Single Receptacle Arrow Hart 1876  Single Receptacle Arrow Hart 1876W Grounded  Single Receptacle
Straight blade receptacle. Meets all UL and CSA specifications. Triple wire line contacts provide excellent long-term plug retention. High impact and chemical-resistant nylon face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. 20 amp, 250 volt. Straight blade receptacle. Meets all UL and CSA specifications. Triple wire line contacts provide excellent long-term plug retention. High impact and chemical-resistant nylon face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. 20 amp, 250 volt. Straight blade receptacle. Meets all UL and CSA specifications. Triple wire line contacts provide excellent long-term plug retention. High impact and chemical-resistant nylon face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. 20 amp, 250 volt.
RECEPTACLE SGL LT ALMOND 250V Cooper 270V10 Grounded  Duplex Receptacle Cooper 270W Grounded  Duplex Receptacle
Straight blade receptacle. Meets all UL and CSA specifications. Triple wire line contacts provide excellent long-term plug retention. High impact and chemical-resistant nylon face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. 20 amp, 250 volt. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements. Built-in wire stripper for number 14 wire. Built-in wire looper for pre-looping conductors. Screw-catch feature eliminates need to hand-thread screw and possible cross-threading. Double wipe ground contacts. Split circuit break-off tab. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire only. 15 amp/125 volt. UL Listed, NOM certified, meets CSA requirements.
Feit 75A/RS/TF-130 Incandescent Lamp Atron 163TTBR Traditional Wall Plate AmerTac 2TTPW Round Corner Wall Plate
Teflon coated glass to reduce breakage and shattering. For open fixtures over food processing and outdoor lighting. Heavy-duty multi-filament resists vibration. Medium brass base resists vibration and corrosion. 130 volt. Traditional square corner design. With screws. 5" height x 4-3/4" width x 1/4" depth. With screws. 5" height x 4-5/8" width x 1/4" depth.
Cooper TR817W-BOX Tamper Resistant Single Receptacle Cooper TR817V-BOX Tamper Resistant Single Receptacle Jandorf 61016 Single Electrical Receptacle
Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. Tamper resistant receptacles have a UL Listed shutter system. cULus Listed. 15 amp, 125 volt. Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. Tamper resistant receptacles have a UL Listed shutter system. cULus Listed. 15 amp, 125 volt. Jandorf Electrical Receptacle, Single, 3 Poles, 3 Wires, 15 A, 125 V, Black, CSA Certified, For Indoor Use
Jandorf 61017 Single Electrical Receptacle Cooper TR1877W-BXSP Tamper Resistant Single Receptacle Cooper TR1877V-BXSP Tamper Resistant Single Receptacle
Jandorf Electrical Receptacle, Single, 3 Poles, 3 Wires, 15 A, 125 V, White, CSA Certified, For Indoor Use Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. Tamper resistant receptacles have a UL Listed shutter system. 20 amp, 125 volt. Meets all UL 498 requirements. Triple wire line contacts provide excellent long-term plug retention. Arc-resistant thermostat face. Side wire terminals accept up to #10 solid or stranded wire. Terminal screws backed out. Tamper resistant receptacles have a UL Listed shutter system. 20 amp, 125 volt.
Arrow Hart TRBR20W-BXSP Tamper Resistant Duplex Receptacle Arrow Hart TRBR20V-BXSP Tamper Resistant Duplex Receptacle Arrow Hart Arrow Link 5252  Duplex Receptacle
High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal Specifications WC-596. UL Listed. Tamper resistant receptacles have a UL Listed shutter system. High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal Specifications WC-596. UL Listed. Tamper resistant receptacles have a UL Listed shutter system. High impact and chemical-resistant nylon face. Rigid glass reinforced nylon base. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Long, broad mounting strap. Meets all UL 498 requirements UL Listed. Screw-catch feature speeds mounting of wall plates. Combination slot/Phillips/Robertson terminal and mounting screws. 5-leaf solid brass line contacts for lowest heat rise, smooth plug blade insertion and long term retention.
Cooper TWRBR15V Tamper Resistant Weatherproof Duplex Receptacle Cooper TWRBR15W-BXSP Tamper Resistant Weatherproof Duplex Receptacle Atron 161TT Traditional Wall Plate
Tamper and weather resistant commercial grade duplex receptacle with a UL Listed shutter system, back and side wiring. -4 to 158 degrees F temperature rating. Withstands 2000 volts per UL498. Body is thermoplastic nylon, the strap and terminal clamps are nickel plated steel. The contacts are a brass alloy. UL Listed to UL498, UL Certified to CSA C22.2, no. 42, UL verified to Fed. Spec. WC-596G, and NOM/ANSI Certified. Meets UL 94 flammability requirements; V2 rated. TR and WR designations provide visual identification. UL, cULus Listed. Tamper and weather resistant commercial grade duplex receptacle with a UL Listed shutter system, back and side wiring. -4 to 158 degrees F temperature rating. Withstands 2000 volts per UL498. Body is thermoplastic nylon, the strap and terminal clamps are nickel plated steel. The contacts are a brass alloy. UL Listed to UL498, UL Certified to CSA C22.2, no. 42, UL verified to Fed. Spec. WC-596G, and NOM/ANSI Certified. Meets UL 94 flammability requirements; V2 rated. TR and WR designations provide visual identification. UL, cULus Listed. Traditional square corner design. With screws. 5" height x 4-3/4" width x 1/4" depth.
AmerTac 935TTAL Wall Plate AmerTac 90TVB Rectangular Wall Plate AmerTac Continental 94TN Rectangular Wall Plate
With screws. 5" height x 4-5/8" width x 1/4" depth. With screws. 5" height x 3" width x 1/4" depth. With screws. 5" height x 3" width x 1/4" depth.
AmerTac Studio 61TCH Rectangular Wall Plate AmerTac Sonoma 76TN Rectangular Wall Plate Cooper TWRBR20V Tamper Resistant Weatherproof Duplex Receptacle
With screws. 5-1/8" height x 3-1/6" width x 3/8" depth. With screws. 5-1/8" height x 3" width x 1/4" depth. Tamper and weather resistant commercial grade duplex receptacle with a UL Listed shutter system, back and side wiring. -4 to 158 degrees F temperature rating. Withstands 2000 volts per UL498. Body is thermoplastic nylon, the strap and terminal clamps are nickel plated steel. The contacts are a brass alloy. UL Listed to UL498, UL Certified to CSA C22.2, no. 42, UL verified to Fed. Spec. WC-596G, and NOM/ANSI Certified. Meets UL 94 flammability requirements; V2 rated. TR and WR designations provide visual identification. UL, cULus Listed.
Cooper TWRBR20W-BXSP Tamper Resistant Weatherproof Duplex Receptacle AmerTac Sonoma 76TBR Rectangular Wall Plate AmerTac Sonoma 76TTBR Rectangular Wall Plate
Tamper and weather resistant commercial grade duplex receptacle with a UL Listed shutter system, back and side wiring. -4 to 158 degrees F temperature rating. Withstands 2000 volts per UL498. Body is thermoplastic nylon, the strap and terminal clamps are nickel plated steel. The contacts are a brass alloy. UL Listed to UL498, UL Certified to CSA C22.2, no. 42, UL verified to Fed. Spec. WC-596G, and NOM/ANSI Certified. Meets UL 94 flammability requirements; V2 rated. TR and WR designations provide visual identification. UL, cULus Listed. With screws. 5-1/8" height x 3" width x 1/4" depth. With screws. 5-1/8" height x 5-1/8" width x 1/4" depth.
AmerTac Continental 94TBB Rectangular Wall Plate Arrow Hart Arrow Link 5352  Duplex Receptacle Arrow Hart Arrow Link 5352  Duplex Receptacle
With screws. 5" height x 3" width x 1/4" depth. High impact and chemical-resistant nylon face. Rigid glass reinforced nylon base. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Long, broad mounting strap. Meets all UL 498 requirements UL Listed. Screw-catch feature speeds mounting of wall plates. Combination slot/Phillips/Robertson terminal and mounting screws. 5-leaf solid brass line contacts for lowest heat rise, smooth plug blade insertion and long term retention. High impact and chemical-resistant nylon face. Rigid glass reinforced nylon base. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Long, broad mounting strap. Meets all UL 498 requirements UL Listed. Screw-catch feature speeds mounting of wall plates. Combination slot/Phillips/Robertson terminal and mounting screws. 5-leaf solid brass line contacts for lowest heat rise, smooth plug blade insertion and long term retention.
Cooper 542B-BOX Duplex Receptacle AmerTac Continental 94TTN Rectangular Wall Plate Arrow Hart CRL530R  Locking Twist Electrical Receptacle
NEMA 5-15R. For pole barns. 15 amp, 125 volt. With screws. 5" height x 5" width x 1/4" depth. Rugged nylon face and body. Clearly marked rating, NEMA configuration and approval listings on receptacle face. One piece brass contacts for performance and minimum heat rise. Back wire terminal clamps for secure wiring. Combination head screws standard - slot/Phillips.
Arrow Hart AH8300W  Duplex Receptacle Arrow Hart AH8300RD  Duplex Receptacle Arrow Hart AH8300V  Duplex Receptacle
Heavy gauge brass line contacts. High impact and chemical-resistant nylon face. Automatic grounding system. Terminal sizes number 14 - 10 AWG. Voltage ratings permanently marked on device. Materials face and base are nylon, strap is 0.05" thick steel, zinc plated, auto ground clip is bronze wire. Line contacts are 0.037" triple-wipe brass, terminal screws  are number 8-32 steel, ground screw is  number 8-32 steel (green). Screw terminal guards are PVC. Listed to UL 498, UL verified to Federal Spec. WC-596G, CSA Certified to C22.2, no. 42. Flammability meets UL 94 requirements; V2.temperature rating: -4 to 158 degrees F. Dielectric voltage: withstands 2000 volts per UL 498. Heavy gauge brass line contacts. High impact and chemical-resistant nylon face. Automatic grounding system. Terminal sizes number 14 - 10 AWG. Voltage ratings permanently marked on device. Materials face and base are nylon, strap is 0.05" thick steel, zinc plated, auto ground clip is bronze wire. Line contacts are 0.037" triple-wipe brass, terminal screws  are number 8-32 steel, ground screw is  number 8-32 steel (green). Screw terminal guards are PVC. Listed to UL 498, UL verified to Federal Spec. WC-596G, CSA Certified to C22.2, no. 42. Flammability meets UL 94 requirements; V2.temperature rating: -4 to 158 degrees F. Dielectric voltage: withstands 2000 volts per UL 498. Heavy gauge brass line contacts. High impact and chemical-resistant nylon face. Automatic grounding system. Terminal sizes number 14 - 10 AWG. Voltage ratings permanently marked on device. Materials face and base are nylon, strap is 0.05" thick steel, zinc plated, auto ground clip is bronze wire. Line contacts are 0.037" triple-wipe brass, terminal screws  are number 8-32 steel, ground screw is  number 8-32 steel (green). Screw terminal guards are PVC. Listed to UL 498, UL verified to Federal Spec. WC-596G, CSA Certified to C22.2, no. 42. Flammability meets UL 94 requirements; V2.temperature rating: -4 to 158 degrees F. Dielectric voltage: withstands 2000 volts per UL 498.
AmerTac Studio 61TTCH Rectangular Wall Plate Arrow Hart RhinoBox L520R Locking Electrical Receptacle Hardlock CWL620R Ground Lock Single Electrical Receptacle
With screws. 5-1/8" height x 3-1/7" width x 3/8" depth. Rugged nylon face and body. Clearly marked rating, NEMA configuration and approval listings on receptacle face. One piece brass contacts for performance and minimum heat rise. Back wire terminal clamps for secure wiring. Combination head screws standard - slot/Phillips. High impact resistant nylon face and body. Combination head terminal and mounting screws. One piece, wrap around mounting strap. Back wire terminal clamps for easy, secure wiring. One piece brass contacts offer superior design and minimum heat rise. UL Listed.
AmerTac Continental 94TTBB Rectangular Wall Plate Arrow Hart CRL1420R  Locking Twist Electrical Receptacle Arrow Hart CRL630R  Locking Twist Electrical Receptacle
With screws. 5" height x 5" width x 1/4" depth. High impact-resistant nylon face and body. One piece wraparound mounting strap for added strength and durability. Color-coded body to identify amperage. High impact resistant nylon face and body. Combination head terminal and mounting screws. One piece, wrap around mounting strap. Back wire terminal clamps for easy, secure wiring. One piece brass contacts offer superior design and minimum heat rise. UL Listed.
Cooper IG8300RN  Duplex Receptacle RECEPT DPLX TAM/RESIST LT ALMD RCPT DPLX GFCI ST 15A/125V BR
Meets all UL 498 "Hospital Grade" requirements, Federal specifications WC-596. Grounding system isolated from common building ground. Triple wipe line contacts provide excellent long-term plug retention. Double wipe ground contacts; one-piece design; reinforced by face and back body to ensure long-term ground retention. High impact-resistant thermoplastic mounting strap, face and back body. Easy access split circuit break-off tab. Automatic ground will ensure wall plate grounding in grounded metal enclosure. Face/body assembled with dual drive pins for superior assembly security. Back and side wire terminals accept #14, #12 or #10 solid or stranded wire. Terminal screws backed out; ready for wiring. Combination slot/Phillips head mounting and terminal screws ease installation with power screwdrivers. 20 amp, 125 volt. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for #14 and #12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to #10 solid or stranded wire. Push in terminals accept #14 solid wire. Screw-catch feature speeds wall plate installation. UL, cULus Listed. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow.
RCPT DPLX GFCI ST 15A/125V BK RCPT DPLX GFCI ST 15A/125V IV RCPT DPLX GFCI ST 15A/125V IV
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow.
RCPT DPLX GFCI ST 15A/125V WH RCPT DPLX GFCI ST 15A/125V WH GFCI DUPLEX 15 LA
GFCI DUPLEX 15 LA
Our Price: $13.43
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow.
Arrow Hart Hart-Lock CWL515R Single Locking Electrical Receptacle GFCI RECEPT AUTOTEST 15A IVORY GFCI RECEPT AUTOTEST 15A WHITE
Single locking receptacle. Glass reinforced nylon body and face. One piece brass contacts. Back and side wire terminal clamps. 15 amp - 125 volt. CSA certified. . Should be installed only on a grounded 125 volt AC circuit which is protected by a single fuse or circuit breaker. End of life function stops voltage in the event of a GFCI component failure. 8 back wiring holes and side wire screws accept up to 12 gauge wire. LED status indicator, color matched wall plate and screws. Meets UL 943 requirements. 15 amp, 125 volt. Should be installed only on a grounded 125 volt AC circuit which is protected by a single fuse or circuit breaker. End of life function stops voltage in the event of a GFCI component failure. 8 back wiring holes and side wire screws accept up to 12 gauge wire. LED status indicator, color matched wall plate and screws. Meets UL 943 requirements. 15 amp, 125 volt.
GFCI RECEPT AUTOTEST 20A WHITE GFCI RECEPT AUTOTEST 20A IVORY GFCI RECEPT TR AUTO 15A WHITE
UL 943-2006 compliant. Lock out function will not allow GFCI to reset if wired incorrectly. End of life function stops voltage in the event of a GFCI component failure. 20 Amp/125 Volt AC. 8 back wiring holes and side wire screws accept up to 12 gauge wire. LED status indicator, color matched wall plate and screws. UL 943-2006 compliant. Lock out function will not allow GFCI to reset if wired incorrectly. End of life function stops voltage in the event of a GFCI component failure. 20 Amp/125 Volt AC. 8 back wiring holes and side wire screws accept up to 12 gauge wire. LED status indicator, color matched wall plate and screws. Meets new 2008 NEC Code tamper resistant requirements. Helps prevent improper insertion of foreign objects. UL 943-2006 compliant. Lock out function will not allow GFCI to reset if miss-wired. End of life function stops voltage in the event of a GFCI component failure. 125 Volt AC. 8 back wiring holes and side wire screws accept up to 12 gauge wire. LED status indicator, color matched wall plate and screws.
GFCI RECEPT TR AUTO 15A IVORY RCPT DPLX GFCI ST 20A/125V IV RCPT DPLX GFCI ST 20A/125V WH
Meets new 2008 NEC Code tamper resistant requirements. Helps prevent improper insertion of foreign objects. UL 943-2006 compliant. Lock out function will not allow GFCI to reset if miss-wired. End of life function stops voltage in the event of a GFCI component failure. 125 Volt AC. 8 back wiring holes and side wire screws accept up to 12 gauge wire. LED status indicator, color matched wall plate and screws. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow.
GFCI 20A LA                   Cooper 1107W Decorator  Duplex Receptacle GFCI RECEPT TR AUTO 20A WHITE
GFCI 20A LA
Our Price: $15.24
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Longer, wider strap provides 40 percent more contact area to wall board. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire and wire looper for pre-looping. Combination slot/Phillips head mounting and terminal screws for installation with power screwdrivers. Terminal screws backed out - ready for wiring. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no. E15058), Fed. Specs. WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. Meets new 2008 NEC Code tamper resistant requirements. Helps prevent improper insertion of foreign objects. UL 943-2006 compliant. Lock out function will not allow GFCI to reset if miss-wired. End of life function stops voltage in the event of a GFCI component failure. 125 Volt AC. 8 back wiring holes and side wire screws accept up to 12 gauge wire. LED status indicator, color matched wall plate and screws.
GFCI RECEPT TR AUTO 20A IVORY Cooper 1107V Decorative  Duplex Receptacle Arrow Hart CRL1430R  Locking Electrical Receptacle
Meets new 2008 NEC Code tamper resistant requirements. Helps prevent improper insertion of foreign objects. UL 943-2006 compliant. Lock out function will not allow GFCI to reset if miss-wired. End of life function stops voltage in the event of a GFCI component failure. 125 Volt AC. 8 back wiring holes and side wire screws accept up to 12 gauge wire. LED status indicator, color matched wall plate and screws. Longer, wider strap provides 40 percent more contact area to wall board. Virtually eliminates floating installations. Built-in wire stripper for number 14 and number 12 wire and wire looper for pre-looping. Combination slot/Phillips head mounting and terminal screws for installation with power screwdrivers. Terminal screws backed out - ready for wiring. Side wire terminals accept up to number 10 solid or stranded wire. Push-in terminals accept number 14 solid wire. Temperature range of -40 to 65 degrees C. Meets all UL 498 requirements, (file no. E15058), Fed. Specs. WC-596G, NOM Certified, CSA Certified, C22.2 no.42. Standard Grade: (file no.6914) (6233-01). Meets flammability requirements per UL94, V2 rated. 15 amp, 125 volt. High impact-resistant nylon face and body. One piece wraparound mounting strap for added strength and durability. Color-coded body to identify amperage.
RCPT DPLX GFCI ST 20A/125V BR RCPT DPLX GFCI ST 20A/125V BK RCPT DPLX GFCI TWR ST 15AMP IV
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable and a red indicator light will glow. Tamper and weather resistant duplex GFCI, specification grade, back and side wiring. Performs periodic self-tests to ensure integrity of GFCI protection. Visual trip indicator light gives quick notification of a tripped or "end of life" condition. Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Line-load miswiring protection. GFCIs will not provide power when wired incorrectly. UL Listed.
RCPT DPLX GFCI TWR ST 15AMP WH Cooper CWL1020R Ground Lock Single Receptacle RCPT DPLX GFCI TR SLFTST15A IV
Tamper and weather resistant duplex GFCI, specification grade, back and side wiring. Performs periodic self-tests to ensure integrity of GFCI protection. Visual trip indicator light gives quick notification of a tripped or "end of life" condition. Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Line-load miswiring protection. GFCIs will not provide power when wired incorrectly. UL Listed. High impact-resistant nylon face and body. One piece wraparound mounting strap for added strength and durability. Color-coded body to identify amperage. NEMA L10-20. Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed.
RCPT DPLX GFCI TR SLFTST15A WH GFCI TAMPER RESISTANT 15A LA  Osram Sylvania 10886 Xenon Incandescent Lamp
Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Vibration resistant, garage door opener bulb. 120 volts.
RECEPT GFCI TR SLF/TST 15A SG RECEPT GFCI TR SLF/TST 15A ORB RECEPT DPLX SIDE WIRE 15A 125V
Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Triple wipe line contacts provide long-term plug retention. Double wipe ground contacts. 0.050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Side wire terminals accept up to #10 solid or stranded wire. Meets all UL 498 requirements UL Listed.
RCPT DPLX GFCI TR SLFTST20A IV RCPT DPLX GFCI TR SLFTST20A WH GFCI TAMPER RESISTANT 20A LA
Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed. Self-Test GFCI conducts an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available and status indicator light will glow red. Additionally, GFCIs incorporate a safety lock-out function to protect against mis-wired line-load connections and GFCI circuitry damage. Tamper resistant shutters. UL Listed.
RCPT GFCI TR ST 15AMP 2P3W DS RCPT DPLX GFCI TWR ST 20AMP IV RCPT DPLX GFCI TWR ST 20AMP WH
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. UL Listed. Tamper and weather resistant duplex GFCI, specification grade, back and side wiring. Performs periodic self-tests to ensure integrity of GFCI protection. Visual trip indicator light gives quick notification of a tripped or "end of life" condition. Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Line-load miswiring protection. GFCIs will not provide power when wired incorrectly. UL Listed. Tamper and weather resistant duplex GFCI, specification grade, back and side wiring. Performs periodic self-tests to ensure integrity of GFCI protection. Visual trip indicator light gives quick notification of a tripped or "end of life" condition. Meets and exceeds 10 kA short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Line-load miswiring protection. GFCIs will not provide power when wired incorrectly. UL Listed.
RCPT GFCI TR ST 15AMP 2P3W SG RCPT GFCI TR ST 15AMP 2P3W WS RECEPTACLE DUPLEX 2P 3W 15 LA
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. UL Listed. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. UL Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed.
GFCI/NIGHTLIGHT TAMP/RESIS 15A RCPT DPLX AFCI TR 15A/125V WH RCPT DPLX AFCI TR 15A/125V IV
Automatic testing GFCI receptacle with nightlight. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant, contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. Specification grade. 2-pole, 3-wire grounding. UL Listed. Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards. Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards.
RCPT DPLX AFCI TR 15A/125V LA LIGHT NIGHT GFCI IVORY 15A    LIGHT NIGHT GFCI WHITE 15A
Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards. Automatic testing GFCI receptacle with nightlight. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant, contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. Specification grade. 2-pole, 3-wire grounding. UL Listed. Automatic testing GFCI receptacle with nightlight. If no GFCI protection is present, the receptacle will render itself inoperable. Tamper resistant, contains a UL listed safety shutter system that prevents the insertion of foreign objects into receptacles. The safety shutters will open only upon insertion of a 2-prong or 3-prong plug. Specification grade. 2-pole, 3-wire grounding. UL Listed.
RCPT DPLX AFCI TR 20A/125V WH RCPT DPLX AFCI TR 20A/125V IV RCPT DPLX AFCI TR 20A/125V LA
Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards. Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards. Protects against arc faults in wiring resulting from damaged insulation and other causes. Designed to recognize an arc fault and then quickly tripping to stop the flow of electricity to prevent the electrical system from starting a fire. Tamper resistant shutters. Large visual LED indicator light gives quick notification of tripped or end-of-life condition. Heavy duty thermoplastic construction. Tri-combo head terminal and mounting screws. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories UL 1699A and UL 498 safety standards.
RECEPT DUPLX B/S-WIRE 15A 125V RECEPT DUPLEX DECO LA         RCPT DPLX AF/GF TR LA 15A 125V
RECEPT DUPLEX DECO LA
Our Price: $26.88
High impact-resistant thermoplastic face. Triple wipe line contacts for long-term plug retention. Double wipe ground contacts for ground retention. .050" thick steel wrap-around mounting strap zinc-plated for corrosion resistance. Easy access split circuit break-off tab. Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure. Back and side wire terminals accept #14, #12 and #10 solid or stranded wire. Terminal screws backed out. Combination slot/Phillips head mounting and terminal screws. Meets all UL 498 requirements. Federal specifications WC-596. Bulk Pak. UL Listed. Receptacle is tamper resistant with a UL Listed shutter system and impact-resistant thermoplastic face and back body that is virtually unbreakable. The 2008 National Electrical Code (NEC) states that "Effective January 1, 2008, all receptacles installed in new dwelling units must be tamper-resistant." Features a wire stripper for number 14 and number 12 wire, extra long and wide mounting straps and tri-combo screws that accept slotted, Phillips and Robertson-head tools. Terminal screws are backed out and ready to wire. Side-wire terminals accept up to number 10 solid or stranded wire. Push in terminals accept number 14 solid wire. Screw-catch feature speeds wall plate installation. 15 amp, 125 volt. NEMA 5-15R. UL, cULus Listed. Duplex self-test AF/GF with standard-size wallplate, back and side wired. 15A/125V NEMA 5-15R. 2-pole, 3-wire grounding. Wire size number 14 - 10 AWG. Both arc fault protection and ground fault protection.  Provides protection from series arcs, parallel arcs, and ground faults. Self-test GFCI technology. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Ground termination with back wire clamp. Automatic grounding system eliminates the need for bonding jumper in grounded metal enclosure. Tapered back wire openings handle multiple wire sizes and types for applications up to number 10 AWG solid or stranded wire. Lock-out functionality prevents mis-wired line-load connections and GFCI/AFCI circuitry damage. Visual indicator light provides quick visual reference of a tripped or end of life condition. Tamper resistant (TR) shutters comply with 2014 NEC Article 406.12. Terminal screws backed out and ready to wire. Matching standard size thermoplastic wallplate included.
RCPT DPLX AF/GF TR IV 15A 125V RCPT DPLX AF/GF TR WH 15A 125V RCPT/SWTCH GFCI MD WLPLT15A IV
Duplex self-test AF/GF with standard-size wallplate, back and side wired. 15A/125V NEMA 5-15R. 2-pole, 3-wire grounding. Wire size number 14 - 10 AWG. Both arc fault protection and ground fault protection.  Provides protection from series arcs, parallel arcs, and ground faults. Self-test GFCI technology. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Ground termination with back wire clamp. Automatic grounding system eliminates the need for bonding jumper in grounded metal enclosure. Tapered back wire openings handle multiple wire sizes and types for applications up to number 10 AWG solid or stranded wire. Lock-out functionality prevents mis-wired line-load connections and GFCI/AFCI circuitry damage. Visual indicator light provides quick visual reference of a tripped or end of life condition. Tamper resistant (TR) shutters comply with 2014 NEC Article 406.12. Terminal screws backed out and ready to wire. Matching standard size thermoplastic wallplate included. Duplex self-test AF/GF with standard-size wallplate, back and side wired. 15A/125V NEMA 5-15R. 2-pole, 3-wire grounding. Wire size number 14 - 10 AWG. Both arc fault protection and ground fault protection.  Provides protection from series arcs, parallel arcs, and ground faults. Self-test GFCI technology. Meets and exceeds 10ka short circuit testing and Underwriters Laboratories (UL) UL943 safety standards. Ground termination with back wire clamp. Automatic grounding system eliminates the need for bonding jumper in grounded metal enclosure. Tapered back wire openings handle multiple wire sizes and types for applications up to number 10 AWG solid or stranded wire. Lock-out functionality prevents mis-wired line-load connections and GFCI/AFCI circuitry damage. Visual indicator light provides quick visual reference of a tripped or end of life condition. Tamper resistant (TR) shutters comply with 2014 NEC Article 406.12. Terminal screws backed out and ready to wire. Matching standard size thermoplastic wallplate included. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. With toggle switch. Includes mid-size wall plate. Rating 15 amp, 125 volts, NEMA 5-15R. UL Listed.
WALLPLATE SWITCH COMBO GFCI/SP GFCI SWITCH 1POLE LA          Feit 100A/RS/TF-130 Incandescent Lamp
GFCI SWITCH 1POLE LA
Our Price: $28.15
Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. With toggle switch. Includes mid-size wall plate. Rating 15 amp, 125 volts, NEMA 5-15R. UL Listed. Automatic testing GFCI receptacle. If no GFCI protection is present, the receptacle will render itself inoperable. With toggle switch. Includes mid-size wall plate. Rating 15 amp, 125 volts, NEMA 5-15R. UL Listed. Teflon coated glass to reduce breakage and shattering. For open fixtures over food processing and outdoor lighting. Heavy-duty multi-filament resists vibration. Medium brass base resists vibration and corrosion. 130 volt.
SWCH GFCI BLNKFACE 20A/120V IV RCPT GFCI BLNKFACE 20A/120V WH RCPT DPLX GFCI ST15A N/WLPT IV
Specification grade blank face GFCI. Fully compliant with all latest UL 943 (4th edition) Class A GFCI, UL 498 requirements and UL 508 for motor control switch horsepower rating, including the latest self testing requirements. GFCI lock-out function protects from miswired line-load connections and GFCI circuitry damage. Compact design provides maximum wiring room. Device and wallplate mounting screws are capti