Home > HARDWARE > CONSTRUCTION HARDWARE > JOIST HANGERS & CONNECTORS > FOUNDATION ANCHORS
Sort By:
1
Village Ironsmith LS100 Standard Lag Screw Set CAP SCREW BUTTON 75MM M6THREAD LL Buildsite V500 Column Socket
Used to secure railing floor flanges to wood surfaces (1 package required for each flange). Color-coded yellow packaging, labeling, and POS materials for easy selection. M6 RH thread. 316 stainless steel. Use with Ram Tail barrel jaw. Use to mount columns to wood surfaces with LS100 lag screws, or to concrete with MA100 masonry anchors, fasteners NOT INCLUDED. Manufactured heavy-duty steel construction, baked-on powder paint. Fits 1" x 1" Column.
LL Buildsite LT200 Lambs Tongue Deckorators 74834 Railing Connector LL Buildsite ST100 Stub Support
Decorative scroll for posts at railing run ends. Heavy-duty steel with baked-on powder coating. Color-coded yellow packaging, labeling, and POS materials for easy selection as anchoring or ornamental. 2-1/4" Depth. Pre-drilled to ensure accurate attachment of the railing to the post. Connectors can be used on both railing and composite materials. Includes stainless steel screws. Use for attaching actual 1-1/2" x 3-1/2" rails. Intermediate support for rails. Use with 4' or 6' rail sections. 5/8" Depth.
Deckorators 74815 Round Baluster Connector Deckorators 74818 Stair Connector Deckorators 74817 Stair Connector
Comes with stainless steel screws and will install ten classic balusters. Allows classic balusters to be secured to the rail without drilling. Can be used on both wood and composite railings. ACQ and CA compliant. Designed to work with stair angles between 30 to 35 degrees and works with both wood and composite materials. Comes with stainless steel screws and will install ten classic balusters. ACQ and CA compliant. Designed to work with stair angles between 30 to 35 degrees and works with both wood and composite materials. Comes with stainless steel screws and will install ten classic balusters. ACQ and CA compliant.
TENSIONER 75MM CYLINDRICAL    LL Buildsite FF125 Floor Flange Rail CABLE RAILING WASHER FLAT 10PK
Use with Ram Tail threaded jaws or swage stud. Thru-post tensioning end. For use with the 1-1/4" Rail systems (Classic, Metropolitan and Traditional). Ram Tail         Cable Railing Flat Washer, 316 Marine Grade Stainless Steel
CABLE RAILING HEX NUT 10PK    LL Buildsite ND125 Rail Fastener SPANNING TOOL MULTI SIZED
M6 RH thread. No drill connectors for use with rail systems to mount rails to post (1 package required for each rail section). Manufactured heavy-duty steel construction with baked-on powder paint. Engineered for value and ease of installation. Color-coded packaging, labeling, and POS materials for easy selection. Fits all Ram Tail fittings.
LL Buildsite NP125 Newell Post TENSIONER 115MM CYLINDRICAL   EYE PLATE SQUARE 2PACK
Use with rail systems for installation. Manufactured heavy-duty steel construction with baked-on powder paint. Engineered for value and ease of installation. Color-coded packaging, labeling, and POS materials for easy selection. Use for Classic rails. Flat black (plastic) cap included. Fits 1-1/4" Rail. Use with Ram Tail threaded jaws or swage stud. Thru-post tensioning end. Use with turnbuckle or fork jaw. Size: 1.25" wide x 1" long.
EYE JAW CABLE HAND RAILING    CABLE HAND RAILING BARREL JAW FORK JAW CABLE HAND RAILING
For use with 3mm cable. M6 RH Thread. For use with 3mm cable. For use with 3mm cable.
CABLE RAIL LAG JAW            CABLE SCREW LAG EYE           LL Buildsite MP125 Newell Post
For use with 3mm cable. 316 stainless steel. Use with rail systems for installation. Manufactured heavy-duty steel construction with baked-on powder paint. Engineered for value and ease of installation. Color-coded packaging, labeling, and POS materials for easy selection. Use for Metropolitan & Traditional rails. Fits 1-1/4" Rail.
CABLE RAIL JAW 45MM           Marshall FVAW Round Foundation Vent Area Wall LL Buildsite Classic CR425 Ornamental Railing
M6 RH thread. For use with 3mm cable. Rounded bottom corners for extra safety. Stamped from single steel sheet. Bright finish reflects light into basement. Hole in flanges for bolting to wall. Deep corrugation stiffens against back fill. All back filling should be done gradually to prevent excessive pressure against area wall. 19-1/2" Wdth. x 10" Dpth. Traditional railing design featuring a 6" On Center Twisted Spindle; installs using other Village Ironsmith accessories such as Classic Newel post, Floor flange and no-drill connector; 28" rail panel height.
Deckorators Classic Round Baluster Vestal AD459 Ash Dump Vestal ST-88 Cleanout Door
26" balusters are designed to build a 36" high rail. 32" balusters are designed to build a 42" high rail. 2.5 balusters are needed per lineal foot of railing. Install to wood or composite railings. Cooled ashes are swept into ash dump to be cleaned later. USA made. Allows debris to be swept and removed that has collected in the chimney. Domestic.
CABLE RAIL JAW 75MM           CABLE RAILING ACORN NUT 10PK  SWAGE STUD THREADED CABLE 3MM
M6 RH thread. For use with 3mm cable. M6 RH thread. Requires swaging tool. Use with 3mm wire rope M6 RH Thread.
Marshall AWR12/680 Round Standard Area Wall Amerimax 75204 Area Wall LL Buildsite Classic CR625 Ornamental Railing
Stamped from single steel sheet with rolled edges for added safety. Bright finish reflects light into basement. Holes in flanges for bolting to wall. Deep corrugation stiffens against back fill. All back fill should be done gradually to prevent excessive pressure against area wall. 37" Wdth. x 16" Dpth. No sharp edges, won't damage or dent. Predrilled for easy installation and can be bolted together. Units can be combined for added height. Cover not included. 37" Wdth. x 16" Dpth. Traditional railing design featuring a 6" On Center Twisted Spindle; installs using other Village Ironsmith accessories such as Classic Newel post, Floor flange and no-drill connector; 28" rail panel height.
TURNBUCKLE ASSEMBLY           Deckorators Classic Round Baluster Deckorators Classic Round Baluster
For use with 3mm cable. 26" balusters are designed to build a 36" high rail. 32" balusters are designed to build a 42" high rail. 2.5 balusters are needed per lineal foot of railing. Install to wood or composite railings. 26" balusters are designed to build a 36" high rail. 32" balusters are designed to build a 42" high rail. 2.5 balusters are needed per lineal foot of railing. Install to wood or composite railings.
CUTTER WIRE 3MM               POST SLEEVES RAILING          Frost King GS316 Wedge Gutter Scoop
High-quality cable cutters. Cuts up to 4mm cable. Use on mid-posts where cable passes through to prevent chaffing. Removes leaves and dirt easily. Also can be used to scatter salt in the winter, spread fertilizer in the spring, dish out pet food and fill bird feeders with bird food.
Amerimax 75208 Area Wall ANGLE 2X4IN TRIPLE ZINC 12GA  Marshall AWR18/682 Round Standard Area Wall
No sharp edges, won't damage or dent. Predrilled for easy installation and can be bolted together. Units can be combined for added height. Cover not included. 37" Wdth. x 16" Dpth. Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. Stamped from single steel sheet with rolled edges for added safety. Bright finish reflects light into basement. Holes in flanges for bolting to wall. Deep corrugation stiffens against back fill. All back fill should be done gradually to prevent excessive pressure against area wall. 37" Wdth. x 16" Dpth.
USP Lumber PA66R Post Anchor Amerimax 75210 Area Wall GUTTER CLEAN EXT 2-3FT POLES
Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. No sharp edges, won't damage or dent. Predrilled for easy installation and can be bolted together. Units can be combined for added height. Cover not included. 37" Wdth. x 16" Dpth. For GutterSweep systems. Kit includes 2- 3 ft. long poles for reaching higher gutters.
ANGLE 2X6IN TRIPLE ZINC 12GA  Deckorators 74737 Baroque Baluster TVM 75055 Sill Seal
Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. 2.5 balusters needed per lineal foot of railing. All balusters come with color-matched screws. Will install to wood or composite railings. Designed to fill the air gaps between the sill plate and the foundation wall, reducing air infiltration. It's durable, moisture resistant characteristics prevent water and insect intrusion. Made of high grade polyethylene. Yellow color. Prevents rotting of the sill plate and will not deteriorate.
Deckorators 50152 Baroque Baluster TVM 75035 Sill Seal TVM 75075 Sill Seal
2.5 balusters needed per lineal foot of railing. All balusters come with color-matched screws. Will install to wood or composite railings. Designed to fill the air gaps between the sill plate and the foundation wall, reducing air infiltration. It's durable, moisture resistant characteristics prevent water and insect intrusion. Made of high grade polyethylene. Yellow color. Prevents rotting of the sill plate and will not deteriorate. Designed to fill the air gaps between the sill plate and the foundation wall, reducing air infiltration. It's durable, moisture resistant characteristics prevent water and insect intrusion. Made of high grade polyethylene. Yellow color. Prevents rotting of the sill plate and will not deteriorate.
LL Buildsite Traditional TR475 Ornamental Railing LL Buildsite Metropolitan MR450 Ornamental Railing TENSIONING/FIXED END FOR-8017
Classic railing design featuring a 4" On Center Twisted Spindle. Installs using other Village Ironsmith accessories such as Metropolitan/Traditional Newel post, Floor Flange and No-Drill Connector. Installed height 36" full panel. Contemporary railing design featuring a 4" On Center 1/4" x 1/4" Vertical Pickets; installs using other Village Ironsmith accessories such as Metropolitan/Traditional Newel post, Floor flange and no-drill connector; installed height 36" full panel. Use in straight run applications. 316 stainless steel. Includes (1) tensioning end and (1) fixed end.
USP Lumber MP34 Framing Angle USP Lumber RT7A Double Plate Hurricane/Seismic Anchor FORK JAW CABLE HANDRAILING 5PK
Use for joist/header installations. Does not have tabs. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505; ICBO 5736; DSA PA-076; Dade County, FL 01-0417.11; and  L.A. City RR25303 codes. 18 Gauge. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For use with 3mm cable.
Vestal H88 Cleanout Door Marshall AWR24/683 Round Standard Area Wall USP Lumber RT3A Double Plate Hurricane/Seismic Anchor
Allows debris to be swept and removed that has collected in the chimney. USA made. Stamped from single steel sheet with rolled edges for added safety. Bright finish reflects light into basement. Holes in flanges for bolting to wall. Deep corrugation stiffens against back fill. All back fill should be done gradually to prevent excessive pressure against area wall. 37" Wdth. x 16" Dpth. Ties trusses and rafters to top plates either left or right handed. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. G90 galvanizing finish. Requires 8d nails for installation in plate and rafter/truss. Meets ICC-ES ESR-1465 and FL817 codes. 18 Gauge.
USP Lumber NP Truss Mending Plate Vestal 128 Cleanout Door Marshall AWR30 Round Area Wall
Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Allows debris to be swept and removed that has collected in the chimney. USA made. Stamped from single steel sheet with rolled edges for added safety. Bright finish reflects light into basement. Holes in flanges for bolting to wall. Deep corrugation stiffens against back fill. All back fill should be done gradually to prevent excessive pressure against area wall. 37" Wdth. x 16" Dpth.
USP Lumber RT Hurricane/Seismic Anchor USP Lumber PCP Post Cap Marshall AWR36 Round Area Wall
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Seamless, keeps water off post tops to protect wood from moisture damage. Corrosion-proof and paintable. Requires one 8d HDG or 10d HDG nail for installation. 3-5/8"W - For 4 x 4 Post/Column. Stamped from single steel sheet with rolled edges for added safety. Bright finish reflects light into basement. Holes in flanges for bolting to wall. Deep corrugation stiffens against back fill. All back fill should be done gradually to prevent excessive pressure against area wall. 37" Wdth. x 16" Dpth.
USP Lumber RT8A Double Plate Hurricane/Seismic Anchor CABLE RAIL LAG JAW FIXED END  USP Lumber ST1-TZ Mud Sill Anchor
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For use with 3mm cable. For securing mudsills and framing into concrete slabs or poured stemwalls. Not for block installation or securing concrete sections together between cold joints. Features prebent base flange for proper anchoring into concrete. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets  NER 530 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
LL Buildsite Traditional TR675 Ornamental Railing USP Lumber JA1 Joist Angle USP Lumber JA1-TZ Framing Angle
Classic railing design featuring a 4" On Center Twisted Spindle. Installs using other Village Ironsmith accessories such as Metropolitan/Traditional Newel post, Floor Flange and No-Drill Connector. Installed height 36" full panel. Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge. Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge.
U-CLIP 2X-2X TRIPLE ZINC      USP Lumber KHL33 Heavy Joist Angle GUTTER CLEANING ROTARY SYSTEM
A clip connects a 2x wood member to the face of another wood member; 20 gauge; G-185 galvanizing finish; requires (6) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included. Designed for heavy-duty reinforcement of 90 degree framing intersections. USP primer finish. Requires (2) 5/8" bolts for installation. Meets ICBO 2725, L.A. City RR 25104. 7 Gauge. System includes everything you need to clean and maintain your gutters without stepping foot on a ladder; lightweight and easy to use, extension kit available for higher reach, rotary power for faster, more thorough cleaning; connects to your cordless drill.
Billy Penn 8522 Roof Edge USP Lumber CPB Composite Post Base USP Lumber NP35 Truss Mending Plate
Provides a nice finished appearance to the eave line and the face with its kick-out at the bottom that diverts water from the facia board to eliminate rot. 10' length. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge.
USP Lumber BL Corner Brace USP Lumber TPP24 Prong Mending Plate USP Lumber TPP Truss Mending Plate
Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge. Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge. Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge.
WIRE ROPE 3MM 1X19 100FT SS   USP Lumber RT15 Double Plate Hurricane/Seismic Anchor USP Lumber PB66-6TZ 1-Piece Post Cap 18 ga T
316 stainless steel 1 x 19 3MM. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber PB 2-Piece Split Post Cap Billy Penn 8548 Roof Edge USP Lumber MPA1 Framing Angle
For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Provides a nice finished appearance to the eave line and the face with its kick-out at the bottom that diverts water from the facia board to eliminate rot. 10' length. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
ANGLE 2X-2X TRIPLE ZINC 16GA  USP Lumber RT Hurricane/Seismic Anchor USP Lumber MPA1 Framing Angle
An angle connects two 2x wood members at 90? angles; G185 galvanizing finish; requires (8) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
TURNBUCKLE ASSMBLY5PK         USP Lumber SFP30 Fence Post Connector USP Lumber NP37 Truss Mending Plate
For use with 3mm cable. Install wooden posts permanently or temporarily without digging.  For heavy-duty applications such as long runs of fencing, corner and gate posts, larger wooden gym sets, detached patio decking, wooden sidewalks, seasonal docks, and more. Removable Forcefit clamps and 2-piece construction, increases unit strength and eliminates welds which are potential weak spots. Reverse spike blades offer lateral soil resistance, increased stability, and allows driving without rotating for easy post alignment. Welded steel construction with high tech baked-on finish, rust resistant and 100% environmentally safe. Application information and installation instructions labeled on each. Green Commission finish. 13 Gauge - For 4 x 4 Posts. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge.
LL Buildsite Metropolitan MR650 Ornamental Railing USP Lumber CPB Composite Post Base Billy Penn 8552 Eave Drip
Contemporary railing design featuring a 4" On Center 1/4" x 1/4" Vertical Pickets; installs using other Village Ironsmith accessories such as Metropolitan/Traditional Newel post, Floor flange and no-drill connector; installed height 36" full panel. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved. Protects and covers roof edge; acts as a starter strip for a true edge to align shingles. The face with its kick-out at the bottom diverts rain water from the facia board helping to eliminate rot. 10' length.
Billy Penn 52 Eave Drip USP Lumber BL Reinforcement Corner Brace USP Lumber ST2-TZ Mud Sill Anchor
Adds support to shingles when they extend over the roof's edge. The face, with its kickout at the bottom, diverts rain water from the facia board helping to eliminate rot. 26 Gauge. 10' Length. Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge. For securing mudsills and framing into concrete slabs, poured stemwalls, or concrete block. Not for securing concrete sections together between cold joints. Features prebent base flange for proper anchoring into concrete. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets NER 530 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber EPB Elevated Post Base Vestal 42 Poker Control Fireplace Damper 6 in H LATE MNDG 13/16X3-1/2IN
Allows installer to pre-align posts and to preset post height above concrete floors or footings. Eliminates post-to-concrete contact for reduced moisture damage. Nails fasten to posts for carports, decks or porches. EPB is welded and primed. EBG is galvanized for added corrosion resistance. Not recommended for fence posts or unrestrained (not fixed or fastened at top) applications.. Requires (8) 16d nails for EPB4408, (12) 16d nails for EPB6608, (8) 16d HDG nails for EBG44-TZ . Meets SBCCI, BOCA - NER 505, ICBO 5736, L.A. City RR 25303 and DSA PA-076 codes. For additional information including allowable loads, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Complete with cast iron valve plate and 5-position poker control detached and bolted to body. Coated with black corrosion-resistant paint. No. 30 - Throat Dimensions: 30" front, 23" back, 10" depth - Overall Dimensions: 34" front, 26-3/4" back 13-1/2" depth. No. 36 - Throat Dimensions: 36" front, 29" back, 10" depth - Overall Dimensions: 40" front, 32-3/4" back 13-1/2" depth. No. 42 - Throat Dimensions: 42" front, 35" back, 10" depth - Overall Dimensions: 46" front, 38-3/4" back 13-1/2" depth. USA made. Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge.
USP Lumber PA(E) 2-Sided Post Anchor USP Lumber SCA Stair Angle USP Lumber PA(E) 2-Sided Post Anchor
Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Simplifies stair construction and eliminate the need to calculate and notch stair stringers. Stronger and safer than wood blocking, and the angle and fasteners are hidden from view. Use the SCA9 for single 2x10 stair treads and SCA10 for double 2 x 6 stair treads. Requires 1/4" x 1-1/2" lag bolts. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information on installation, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes.
Billy Penn 8554 Eave Drip Billy Penn 8558 Eave Drip USP Lumber FA3-TZ Foundation Anchor
Protects and covers roof edge; acts as a starter strip for a true edge to align shingles. The face with its kick-out at the bottom diverts rain water from the facia board helping to eliminate rot. 10' length. Protects and covers roof edge; acts as a starter strip for a true edge to align shingles. The face with its kick-out at the bottom diverts rain water from the facia board helping to eliminate rot. 10' length. For securing mudsills and framing into concrete slabs. Do not rely-on for securing concrete sections together between cold joints. Features split flange for nailing to both mudsill and stud for greater framing versatility. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets ICC-ES ESR-2787 codes For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber PA44-TZDP Post Anchor USP Lumber RT10 Double Plate Hurricane/Seismic Anchor USP Lumber CSH-TZ Concealed Stringer Hanger
Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Used to tie wood framing members to resist uplift and lateral forces. G90 galvanizing finishing. Requires 8d nails for installation. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. 18 Gauge. Concealed stair stringer hanger provides a method of connecting a stringer with a hidden hanger. The seat of the hanger is adjustable to match the slope of the stair stringer. Triple Zinc finish. Requires (8) 10d x 1-1/2 HDG nails for header and (5) 10d x 1-1/2 HDG nails for joist. 18 Gauge. Pending IAPMO-ES evaluation.
USP Lumber WE44-TZ Wet Post Anchor USP Lumber RT16A Double Plate Hurricane/Seismic Anchor Billy Penn 101 Starter Strip
Secures posts to concrete in light-duty and medium-duty applications such as patio covers, carports or decks. Formed, one-piece design includes embossing for additional lateral strength. Not  for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires (2) 1/2" HDG bolts or (12) HDG nails for fastening to post. Meets SBCCI, BOCA - NER 530 & NER 608, ICBO 5700, ICBO 2039, ICBO 5531, FL821, FL822, L.A. City RR 25337, and DSA PA-076 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Anchor tie trusses and rafters to top plates and may be used to tie wood framing members to resist uplift and lateral forces. Typical Truss/rafter to double plate installation. Requires Meet ICC-ES ESR-1465 and FL817 codes. Used during the installation of vinyl siding. It provided a means of securing the first bottom piece of siding to the wall.
USP Lumber PA46E-TZ Post Anchor USP Lumber D Post Anchor Amerimax 5601400120 Eave Overhanging Standard Drip Edge
Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Secures nominal sized post to wood surfaces offering some lateral and uplift resistance. May be used only for intermediate posts between fully anchored corner/end posts in rail system. Not Recommended for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d HDG fasteners for post and 16d HDG fasteners for base. Meets ICBO 2039 and L.A. City RR23888 codes. For additional information including allowable loads, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Protects and covers roof edge. Directs run-off into gutters. For new construction and reroofs. Used along gutter line of roof edge. Acts as a starter strip for a true edge to align shingles. The face, with its kickout at the bottom, diverts rain water from the facia board helping to eliminate rot. Standard gauge. 5/8" overhang, throw out included in face size. 2-7/16" X 10' - 1" FACE.
Amerimax 5701419120 Eave Overhanging Drip Edge Amerimax 5701400120 Eave Overhanging Standard Drip Edge USP Lumber A3 Framing Angle
Protects and covers roof edge. Directs run-off into gutters. For new construction and reroofs. Used along gutter line of roof edge. Acts as a starter strip for a true edge to align shingles. The face, with its kickout at the bottom, diverts rain water from the facia board helping to eliminate rot. Standard gauge. 5/8" overhang, throw out included in face size. 2-7/16" X 10' - 1" FACE. Protects and covers roof edge. Directs run-off into gutters. For new construction and reroofs. Used along gutter line of roof edge. Acts as a starter strip for a true edge to align shingles. The face, with its kickout at the bottom, diverts rain water from the facia board helping to eliminate rot. Standard gauge. 5/8" overhang, throw out included in face size. 2-7/16" X 10' - 1" FACE. Eliminates toenailing and increases strength. Requires 10d x 1-1/2" nails for installation. 1-7/16"W1 X 1-7/16"W2 X 2-3/4"L - 18 GAUGE. Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes.
USP Lumber SDJT14-TZ Deck Post Tie USP Lumber SCA Stair Angle USP Lumber C66-TZ 1-Piece Post Beam Cap
Secures 2x joist to posts. Requires 16d HDG nails or 5/8" HDG bolts for installation. 14 Gauge. Simplifies stair construction and eliminate the need to calculate and notch stair stringers. Stronger and safer than wood blocking, and the angle and fasteners are hidden from view. Use the SCA9 for single 2x10 stair treads and SCA10 for double 2 x 6 stair treads. Requires 1/4" x 1-1/2" lag bolts. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information on installation, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. One piece, designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened together to act as a unit. Requires 16d HDG nails for installation. Meets ICC-ES ESR-1280, FL11664, L.A. City RR25749 and Dade County, FL 07-0306.06 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 18 GAUGE.
USP Lumber HCPRS Hurricane/Seismic Anchor Amerimax 75447 1-Piece Egress Modular Window Well Billy Penn Economy 356 Angle Flashing
Used to tie trusses and rafters to top plates, and may be used to tie wood framing members to resist uplift and lateral forces. G90 galvanizing finish. 1-9/16"W opening. Meets ICC-ES ESR-1881, FL821 and L.A. City RR25779 codes. 18 Gauge - 5-1/4"W. Single-part modular system with durable structural foam construction. Snap-together connections. Build-in ladder/steps with non-slip surface. Accommodates all Egress windows from 32" to 48" wide. Increases natural light in basement. Easy to assemble, maintenance-free, rust free and UV-stabilized. Back-fill bracing not required. Complies with IRC 2000 Egress Code. Includes 1 piece. 52" Wdth. x 43" Dpth. An easy way to flash the wall to the roof in an end wall application or the chimney to the roof. 10' length.
Amerimax 77103 Fascia Trim USP Lumber NP39 Truss Mending Plate CABLE 3MM 1 X 19 X 250FT
Maintenance free painted aluminum. Use in conjunction with soffit pieces. 30 degree baked on polyester top coat, enamel finish, with .0175" thickness. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Size: 3mm, 1x19.
USP Lumber CPB Composite Post Base Billy Penn 144 Standard Eave Drip USP Lumber MP9-TZ Framing Angle
Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved. Adds support to shingle when they are extended over roof's edge. The face, with its kickout at the bottom, diverts rain water from the facia board helping to eliminate rot. Standard gauge. 5/8" overhang, throw out included in face size. 2-7/16" X 10' - 1" FACE. May be field adjusted by hand from 0 to 135 degrees, giving framers and do-it-yourselfers flexibility in applications. Bend angle only once. G90 galvanized finish. 10d HDG nails required for installation. Meets SBCCI, BOCA - NER 530, ICBO 5700, FL822, L.A. City RR 25337, DSA PA-06 codes.
USP Lumber C 1-Piece Post Cap Amerimax Economy 5509919120 Eave Overhanging Drip Edge Amerimax Economy 5509900120 Eave Overhanging Drip Edge
For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. One piece, designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened together to act as a unit. Requires 16d HDG nails for installation. Meets ICC-ES ESR-1280, FL11664, L.A. City RR25749 and Dade County, FL 07-0306.06 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 18 GAUGE. Protects and covers roof edge. Directs run-off into gutters. For new construction and reroofs. Used along gutter line of roof edge. Acts as a starter strip for a true edge to align shingles. The face, with its kickout at the bottom, diverts rain water from the facia board helping to eliminate rot. Standard gauge. 5/8" overhang, throw out included in face size. 2-7/16" X 10' - 1" FACE. Protects and covers roof edge. Directs run-off into gutters. For new construction and reroofs. Used along gutter line of roof edge. Acts as a starter strip for a true edge to align shingles. The face, with its kickout at the bottom, diverts rain water from the facia board helping to eliminate rot. Standard gauge. 5/8" overhang, throw out included in face size. 2-7/16" X 10' - 1" FACE.
USP Lumber AC9-TZ Framing Angle USP Lumber AC5-TZ Framing Angle USP Lumber JNP24 Joiner Nail Mending Plate
For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Prong plates with angled, hammer-in prongs. Joins flat surfaces of 2 or more wood members. G90 galvanizing finish. Not intended for structural use OR in truss assembly. No load ratings assigned. 18 Gauge.
USP Lumber PA66-TZDP Post Anchor Amerimax 5504519120 Hemmed Drip Edge Amerimax 5504500120 Hemmed Standard Drip Edge
Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Protects and covers roof edge. Directs run-off into gutters. For new construction and reroofs. Used along gutter line of roof edge. Acts as a starter strip for a true edge to align shingles. The face, with its kickout at the bottom, diverts rain water from the facia board helping to eliminate rot. Standard gauge. 5/8" overhang, throw out included in face size. 2-1/3" X 10' - 1-1/2" FACE. Protects and covers roof edge. Directs run-off into gutters. For new construction and reroofs. Used along gutter line of roof edge. Acts as a starter strip for a true edge to align shingles. The face, with its kickout at the bottom, diverts rain water from the facia board helping to eliminate rot. Standard gauge. 5/8" overhang, throw out included in face size. 2-1/3" X 10' - 1-1/2" FACE.
USP Lumber JNP28 Joiner Nail Mending Plate USP Lumber AC Framing Angle CABLE 3MM 1 X 19 X 500FT
Prong plates with angled, hammer-in prongs. Joins flat surfaces of 2 or more wood members. G90 galvanizing finish. Not intended for structural use OR in truss assembly. No load ratings assigned. 18 Gauge. For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Size: 3mm, 1x19.
CABLE 3MM 1 X 19 X 1000FT
Size: 3mm, 1x19.
   
 
1