Home > HARDWARE > CONSTRUCTION HARDWARE > JOIST HANGERS & CONNECTORS > POST ANCHORS / CAPS
Sort By:
1
GAF Master Flow EAP EAP412W Oval Soffit Ventilator Maurice Franklin RL-100 Round Screen Louver Maurice Franklin PLW-100 Round Screen Louver
High-impact resin construction, all-purpose intake ventilation. Snap-in for easy installation with 5/16" soffit material. 22 sq. in. NFA. Maurice Franklin Screen Louver, Round, Series: RL-100, 3/16 sq-in Net Free Area, 1 in Cutout Width, 13/32 in Cutout Height, 5 Blades, Aluminum, Mill, 0.02 ga Thickness, 1.219 in Overall Width One piece white polyethylene. Recommended for moisture control in sidewalls construction or other restricted areas.
Maurice Franklin RLW-100 Round Screen Louver Stanley 316489 Weldable Rebar Frost King SP1/12 Construction Insulation
Maurice Franklin Screen Louver, Round, Series: RLW-100, 3/16 sq-in Net Free Area, 1 in Cutout Width, 13/32 in Cutout Height, 5 Blades, Aluminum, White, 0.02 ga Thickness, 1.219 in Overall Width Stanley Weldable Rebar, 1/2 in, NO 4 Nominal, 36 in Overall Length, Steel Creates an insulating barrier that retains heat or cold, seals out weather and damps vibration. Can be used around water heaters, oil burners, heating and air conditioner ducts; prevents heat loss and sweating on pipes, auto hoods and trunks.
Maurice Franklin RL-100 Round Screen Louver Bestvents 510BL Open Air Grille Foundation Vent Maurice Franklin RLW-100 Round Screen Louver
Maurice Franklin Screen Louver, Round, Series: RL-100, 1.21 sq-in Net Free Area, 2-1/2 in Cutout Width, 5/8 in Cutout Height, 6 Blades, Aluminum, Mill, 0.02 ga Thickness, 2.907 in Overall Width Grill wiith a flange and (4) screws to hold it in the foundation opening; has NO flap or slide mechanism to open or close it, so the air can constantly move through. Size: 7-3/4" x 15-1/4" so it easily fits the standard 8" x 16" block foundation opening. Maurice Franklin Screen Louver, Round, Series: RLW-100, 1.21 sq-in Net Free Area, 2-1/2 in Cutout Width, 5/8 in Cutout Height, 6 Blades, Aluminum, White, 0.02 ga Thickness, 2.907 in Overall Width
Maurice Franklin RLB-100 Round Screen Louver Maurice Franklin PLW-100 Round Screen Louver Maurice Franklin PLW-100 Round Screen Louver
Maurice Franklin Screen Louver, Round, Series: RLB-100, 1.21 sq-in Net Free Area, 2-1/2 in Cutout Width, 5/8 in Cutout Height, 6 Blades, Aluminum, Brown, 0.02 ga Thickness, 2.907 in Overall Width One piece white polyethylene. Recommended for moisture control in sidewalls construction or other restricted areas. One piece white polyethylene. Recommended for moisture control in sidewalls construction or other restricted areas.
Maurice Franklin PLB-100 Round Screen Louver Maurice Franklin RLW-100 Round Screen Louver Bestvents 327BL Jumbo Foundation Vent
One piece white polyethylene. Recommended for moisture control in sidewalls construction or other restricted areas. Maurice Franklin Screen Louver, Round, Series: RLW-100, 0.399 sq-in Net Free Area, 1-1/2 in Cutout Width, 9/16 in Cutout Height, 5 Blades, Aluminum, White, 0.02 ga Thickness, 1.813 in Overall Width For King and Queen size brick. Fits 9-1/4" x 16" vent openings. 1-3/4" frame depth and 8" x 8" sized mesh. Mesh is made of aluminum perma kote epoxy charcoal. Frame is made of high-density polypropylene resins. 9-1/4" x 16".
Bestvents 500BL Manual Foundation Vent with Damper Maurice Franklin RL-100 Round Screen Louver Stanley 346965 Weldable Rebar
Bestvents Foundation Vent, Manual, Black Oxide, With Damper Maurice Franklin Screen Louver, Round, Series: RL-100, 0.803 sq-in Net Free Area, 2 in Cutout Width, 5/8 in Cutout Height, 6 Blades, Aluminum, Mill, 0.02 ga Thickness, 2.391 in Overall Width Stanley Weldable Rebar, 1/2 in, NO 4 Nominal, 4 ft Overall Length, Steel, Used in Landscaping
Bestvents 500BR Manual Foundation Vent with Damper Bestvents 500GR Manual Foundation Vent with Damper Maurice Franklin RL-100 Round Screen Louver
Bestvents Foundation Vent, Manual, Brown, With Damper Bestvents Foundation Vent, Manual, Gray, With Damper Maurice Franklin Screen Louver, Round, Series: RL-100, 1.735 sq-in Net Free Area, 3 in Cutout Width, 11/16 in Cutout Height, 6 Blades, Aluminum, Mill, 0.02 ga Thickness, 3-17/32 in Overall Width
Maurice Franklin RLB-100 Round Screen Louver Maurice Franklin RLW-100 Round Screen Louver Maurice Franklin RLB-100 Round Screen Louver
Maurice Franklin Screen Louver, Round, Series: RLB-100, 0.803 sq-in Net Free Area, 2 in Cutout Width, 5/8 in Cutout Height, 6 Blades, Aluminum, Brown, 0.02 ga Thickness, 2.391 in Overall Width Maurice Franklin Screen Louver, Round, Series: RLW-100, 0.803 sq-in Net Free Area, 2 in Cutout Width, 5/8 in Cutout Height, 6 Blades, Aluminum, White, 0.02 ga Thickness, 2.391 in Overall Width Maurice Franklin Screen Louver, Round, Series: RLB-100, 1.735 sq-in Net Free Area, 3 in Cutout Width, 11/16 in Cutout Height, 6 Blades, Aluminum, Brown, 0.02 ga Thickness, 3-17/32 in Overall Width
Maurice Franklin RLW-100 Round Screen Louver RH Tamlyn PC1532 Plywood Clip Maurice Franklin PLW-100 Round Screen Louver
Maurice Franklin Screen Louver, Round, Series: RLW-100, 1.735 sq-in Net Free Area, 3 in Cutout Width, 11/16 in Cutout Height, 6 Blades, Aluminum, White, 0.02 ga Thickness, 3-17/32 in Overall Width With built-in spacer for use when support spacing exceeds the maximum length of an unsupported edge. Boxed. One piece white polyethylene. Recommended for moisture control in sidewalls construction or other restricted areas.
RH Tamlyn PCS716 Plywood Clip RH Tamlyn PCS12 Plywood Clip RH Tamlyn PCS1532 Plywood Clip
Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed.
Stanley 316497 Weldable Rebar Maurice Franklin RL-100 Round Screen Louver Gaf BVSII Block Foundation Vent
Stanley Weldable Rebar, 1/2 in, NO 4 Nominal, 72 in Overall Length, Steel, Used in Landscaping Maurice Franklin Screen Louver, Round, Series: RL-100, 3.5 sq-in Net Free Area, 4 in Cutout Width, 3/4 in Cutout Height, 9 Blades, Aluminum, Mill, 0.02 ga Thickness, 4-5/8 in Overall Width Aluminum vanes, lintel not required. For block, brick, or frame construction. Recommended for high-level ventilation. Galvanized steel and aluminum. 8" x 16" x 2-3/4".
Maurice Franklin RLW-100 Round Screen Louver Maurice Franklin RLB-100 Round Screen Louver Ad Tech T3438CK Mixing Nozzle Kit
Maurice Franklin Screen Louver, Round, Series: RLW-100, 3.5 sq-in Net Free Area, 4 in Cutout Width, 3/4 in Cutout Height, 9 Blades, Aluminum, White, 0.02 ga Thickness, 4-5/8 in Overall Width Maurice Franklin Screen Louver, Round, Series: RLB-100, 3.5 sq-in Net Free Area, 4 in Cutout Width, 3/4 in Cutout Height, 9 Blades, Aluminum, Brown, 0.02 ga Thickness, 4-5/8 in Overall Width Nozzle kit for Ultrabond epoxy 22 oz. system.  Hi-Flow nozzles reduce waste while increasing flow. 15 inch length snaps off to 10 inches if required.  3/8 diameter at tip.  Built in mixing nut allows for fast and easy attachment to cartridge.
RH Tamlyn PCS58 Plywood Clip Duraflo 646015 Soffit Exhaust Ventilator Bestvents A-ELBLACK Foundation Vent
Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. No need to penetrate the roof or wall. For venting bathrooms or dryers. Flapper lets out hot moist air while keeping out cold air. Mounts flush to soffit for virtually invisible installation. Meets CSA codes and standards. Connects to either 4" or 5" ducting or flex hose. Overall size 6.75" x 5.75". With 18" lintel for new construction. Fits standard 8" x 16" vent openings. High density thermo-plastic construction. Automatically opens at 70 degrees Fahrenheit, closes at 40 (approximately). Key working mechanism, bi-metal coil, fully enclosed by protective cover. No electrical hook-up required. Stainless steel and corrosion resistant metal parts. 62 square inches net free area. Heavy-duty aluminum mesh screen, front and back. 8" x 16".
Bestvents 304LGR Foundation Vent Bestvents A-ELBROWN Foundation Vent Acorn IHW16100 Insulation Support Wire 16 in L
With 18" lintel for new construction. Fits standard 8" x 16" vent openings. High density thermo-plastic construction. Automatically opens at 70 degrees Fahrenheit, closes at 40 (approximately). Key working mechanism, bi-metal coil, fully enclosed by protective cover. No electrical hook-up required. Stainless steel and corrosion resistant metal parts. 62 square inches net free area. Heavy-duty aluminum mesh screen, front and back. 8" x 16". With 18" lintel for new construction. Fits standard 8" x 16" vent openings. High density thermo-plastic construction. Automatically opens at 70 degrees Fahrenheit, closes at 40 (approximately). Key working mechanism, bi-metal coil, fully enclosed by protective cover. No electrical hook-up required. Stainless steel and corrosion resistant metal parts. 62 square inches net free area. Heavy-duty aluminum mesh screen, front and back. 8" x 16". Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge.
Bestvents B-EBLACK(MB) Foundation Vent Energy Saver 306MWH Foundation Vent With Damper Energy Saver B-E BROWN (MB) Foundation Vent With Damper
Replaces old-style manual vents. Fits standard 8" x 16" vent openings. Automatically opens at 70 degrees Fahrenheit and closes at 40 (approximately). The key mechanism, bi-metal coil, fully enclosed in protective cover. Stainless steel compression spring with 1 adjustable screw for easy installation. 65 square inch net free area. High-density thermo-plastic construction. Stainless steel and corrosion resistant metal parts. Heavy-duty aluminum mesh screen, front and back. No electrical hook-up required. 8" x 16". Replaces old-style manual vents. Fits standard 8" x 16" vent openings. Automatically opens at 70 degrees Fahrenheit and closes at 40 (approximately). The key mechanism, bi-metal coil, fully enclosed in protective cover. Stainless steel compression spring with 1 adjustable screw for easy installation. 65 square inch net free area. High-density thermo-plastic construction. Stainless steel and corrosion resistant metal parts. Heavy-duty aluminum mesh screen, front and back. No electrical hook-up required. 8" x 16". Replaces old-style manual vents. Fits standard 8" x 16" vent openings. Automatically opens at 70 degrees Fahrenheit and closes at 40 (approximately). The key mechanism, bi-metal coil, fully enclosed in protective cover. Stainless steel compression spring with 1 adjustable screw for easy installation. 65 square inch net free area. High-density thermo-plastic construction. Stainless steel and corrosion resistant metal parts. Heavy-duty aluminum mesh screen, front and back. No electrical hook-up required. 8" x 16".
Bestvents 315CBL Replacement Foundation Vent Energy Saver 306MGR Foundation Vent With Damper Bestvents 315CBR Replacement Foundation Vent
With 1"W frame for new construction or to replace old foundation vents. Fits standard 8" x 16" concrete block opening. Operates automatically without electricity; opens at 70 degrees Fahrenheit, closes at 40 (approximately). Simple homeowner/DIYer snap-in installation, with color matched set screws for additional stability. Removable back for maintenance and cleaning. Screened with 1/8" heavy-duty aluminum mesh. High-density thermo-plastic construction. All metal parts are corrosion resistant stainless steel. Aluminum louvers. No mortar required for installation. 62 square inch net free area. 8" x 16". Replaces old-style manual vents. Fits standard 8" x 16" vent openings. Automatically opens at 70 degrees Fahrenheit and closes at 40 (approximately). The key mechanism, bi-metal coil, fully enclosed in protective cover. Stainless steel compression spring with 1 adjustable screw for easy installation. 65 square inch net free area. High-density thermo-plastic construction. Stainless steel and corrosion resistant metal parts. Heavy-duty aluminum mesh screen, front and back. No electrical hook-up required. 8" x 16". With 1"W frame for new construction or to replace old foundation vents. Fits standard 8" x 16" concrete block opening. Operates automatically without electricity; opens at 70 degrees Fahrenheit, closes at 40 (approximately). Simple homeowner/DIYer snap-in installation, with color matched set screws for additional stability. Removable back for maintenance and cleaning. Screened with 1/8" heavy-duty aluminum mesh. High-density thermo-plastic construction. All metal parts are corrosion resistant stainless steel. Aluminum louvers. No mortar required for installation. 62 square inch net free area. 8" x 16".
Bestvents 315CGR Replacement Foundation Vent Gaf FVRABL Foundation Vent Bestvents 201CA Metal Slider Foundation Vent
With 1"W frame for new construction or to replace old foundation vents. Fits standard 8" x 16" concrete block opening. Operates automatically without electricity; opens at 70 degrees Fahrenheit, closes at 40 (approximately). Simple homeowner/DIYer snap-in installation, with color matched set screws for additional stability. Removable back for maintenance and cleaning. Screened with 1/8" heavy-duty aluminum mesh. High-density thermo-plastic construction. All metal parts are corrosion resistant stainless steel. Aluminum louvers. No mortar required for installation. 62 square inch net free area. 8" x 16". Hi-density polyethylene construction. Auto-open at 70 degrees Fahrenheit, closes at 40 degrees to lower risk of frozen pipes and save energy. Replaces manual vent. Snap-in installation. 57 sq. in. NFVA. 16'' x 8''. Bestvents Foundation Vent, Metal Slider, Cast Aluminum
INSUL R11K 15X40FT MINI-ROLL  INSUL R13K 15IN X 32FT ROLL   Ultra Bond 1 A9-1 Anchoring Adhesive
Kraft faced mini rolls - "Greenguard" certified LEED eligible. Kraft faced mini rolls - "Greenguard" certified LEED eligible. Use for anchoring and doweling. Long working time with a quick cure time. Moisture insensitive, can be used in underwater environments, concrete, hollow block, brick, clay and stone. Ideal for vertical, horizontal, and screen applications, seismic anchoring and bracing, surface crack repair. Ultra high-strength epoxy mixes through a static mixing tube and can also be resealed which means that any remaining material can be saved for later use. Cartridge w/nozzle.
Miraclebond 1350 A9-MB1350HN Anchoring Adhesive Reflectix 2222-16-25 7-Layer Reflective Staple Tab Insulation Acorn IHW24100 Insulation Support Wire 24 in L
Two component (1:1 ratio), 100-percent solids, high aspect ceramic blend, solvent-free, non-sag, high strength, high modulus, moisture insensitive epoxy system. Ideal for use as a bonding agent for almost any material, including metal, concrete, brick, wood, stone, block and other substrates. Can also be used for repairing holes, spalls, cracks in concrete, repairing rotted wood, installing and repairing anchor bolts or hand rails. LIMITATIONS: Minimum substrate and ambient temperature 40 degrees F (4.44 degrees C),  Cartridge with two nozzles; medium duty caulking tool required. Easy installation ? scissors and staple gun are all you need.  3/4" staple tab designed for 16" OC Joists. All season performance.  Great for insulating radiant heating systems.  5/16? thick, multi layer, double bubble reflective insulation .  Reflects 94% of radiant heat.  Class 1, Class A fire rating.  Any seams should be sealed with TVM Metalized Tape for maximum effectiveness. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge.
USP Lumber RS20-R Coiled Strap Ultra Bond 1300 A22-1300N Anchoring Adhesive Acorn IHW16500 Insulation Support Wire 16 in L
Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Two  component (1:1 ratio), 100 percent solids, high modulus, structural epoxy gel. It is a solvent free, low odor high strength, moisture insensitive, non-sag epoxy system. The resin and hardener are uniformly dispensed from a dual cartridge system and mixed simultaneously through a mixing nozzle or available in bulk. Long working time with a full cure in 24 hours. Moisture insensitive, may be used in damp environments, concrete, hollow block, brick, clay and stone. Ideal for vertical, horizontal, and screen applications. Structural bonding of concrete to concrete. Meets ASTM C881-14: Type I, II, IV and V, Grade 3, Class B and C. Cartridges with Nozzle. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge.
INSUL R19K 6.25H X 15L X 94W  INSUL R19K 15IN X 39.16FT ROLL USP Lumber PA66R Post Anchor
Kraft Faced Pro Cut Batts - "Greenguard" certified LEED eligible. Kraft faced rolls - "Greenguard" certified LEED eligible. Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes.
INSUL R11K 15IN X 70.5FT ROLL Lomanco C816W Cornice Vent INSUL R13K 15IN X 93IN BATT
Kraft faced rolls - "Greenguard" certified LEED eligible. All aluminum, rust-free construction; overall size of 8" x 16" louver; 8 x 8 perma-coated aluminum screen attached; pre-drilled holes; unique eyebrow designed louvers provides maximum ventilating capacity with weather infiltration; 65 square inches of net free area. Kraft Faced Pro Cut Batts - "Greenguard" certified LEED eligible.
INSUL R19K 23IN X 94IN BATT   Lomanco C416W Cornice Vent Simpson Strong-Tie LSTA Light Duty Strap Tie
Kraft Faced Pro Cut Batts - "Greenguard" certified LEED eligible. All aluminum, rust-free construction; Overall size of 4" x 16" louver; 8 x 8 perma-coated aluminum screen attached; pre-drilled holes; unique eyebrow designed louvers provides maximum ventilating capacity with weather infiltration; 25 square inches of net free area. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
INSUL R19K 23IN X 39.16FT ROLL Acorn IHW24500 Insulation Support Wire 24 in L USP Lumber LSTA12 Light Capacity Strap Tie
Kraft faced rolls - "Greenguard" certified LEED eligible. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
INSUL R11K 23IN X 70.5FT ROLL LL Buildsite EAC16X4 Rectangle Undereave Vent USP Lumber PCP Post Cap
Kraft faced rolls - "Greenguard" certified LEED eligible. All purpose intake ventilation prepunched nail holes. Surface mount. Corrosion resistant. 16" x 4" vents have 26 sq. ins. of net free area. 16" x 8" vents have 65 sq. ins. of net free area. Seamless, keeps water off post tops to protect wood from moisture damage. Corrosion-proof and paintable. Requires one 8d HDG or 10d HDG nail for installation. 3-5/8"W - For 4 x 4 Post/Column.
CMC PIN04N018 Non-Graded Rebar Pin TVM 2220-24-50 Double Bubble Construction Insulation LL Buildsite EAC16X8 Rectangle Undereave Vent
Reinforced bar, commonly used in concrete and masonry structures. Safe to use; non-toxic; easy to install.  Does not require special protective clothing.  Lowers air conditioning/heating costs.  5/16? thick, multi layer, double bubble reflective insulation in rolls of various widths and lengths.  Reflects 94% of radiant heat. Class 1, Class A fire rating.  Seams should be sealed with TVM Metalized Tape for maximum effectiveness. All purpose intake ventilation prepunched nail holes. Surface mount. Corrosion resistant. 16" x 4" vents have 26 sq. ins. of net free area. 16" x 8" vents have 65 sq. ins. of net free area.
INSUL R30K 16IN X 48IN BATT   USP Lumber CPB Composite Post Base Ad Tech TM22HD Dispensing Tool
Kraft faced batts; "Greenguard" certified LEED eligible. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved. Features an in-line rod system, combined with a specifically designed friction plate that results in exceptional force making dispensing faster and reducing worker exertion and fatigue. Double gripping plates and steel trigger for increased durability and performance. For 22 Oz. cartridges, but comes with adaptable parts which allow for 16 Oz. cartridges as well.
LL Buildsite EAC16X4W Rectangle Undereave Vent LL Buildsite EAC16X4BR Undereave Vent USP Lumber LSTA18 Light Capacity Strap Tie
All purpose intake ventilation prepunched nail holes. Surface mount. Corrosion resistant. 16" x 4" vents have 26 sq. ins. of net free area. 16" x 8" vents have 65 sq. ins. of net free area. All purpose intake ventilation prepunched nail holes. Surface mount. Corrosion resistant. 16" x 4" vents have 26 sq. ins. of net free area. 16" x 8" vents have 65 sq. ins. of net free area. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Bestvents PMS-1BLACK Foundation Vent Bestvents PMS-1BROWN Foundation Vent Bestvents PMS-1 Foundation Vent
With 18"L x 1 3/4"W built-in lintel for new block, brick or frame foundation construction. Durable polypropylene construction. 40 square inches net free area. 1/8" aluminum screen. 8" x 16". With 18"L x 1 3/4"W built-in lintel for new block, brick or frame foundation construction. Durable polypropylene construction. 40 square inches net free area. 1/8" aluminum screen. 8" x 16". With 18"L x 1 3/4"W built-in lintel for new block, brick or frame foundation construction. Durable polypropylene construction. 40 square inches net free area. 1/8" aluminum screen. 8" x 16".
LL Buildsite EAC16X8W Rectangle Undereave Vent LL Buildsite EAC16X8BR Undereave Vent STRAP TIE 3-1/4X16IN TRI-ZINC
All purpose intake ventilation prepunched nail holes. Surface mount. Corrosion resistant. 16" x 4" vents have 26 sq. ins. of net free area. 16" x 8" vents have 65 sq. ins. of net free area. All purpose intake ventilation prepunched nail holes. Surface mount. Corrosion resistant. 16" x 4" vents have 26 sq. ins. of net free area. 16" x 8" vents have 65 sq. ins. of net free area. Wide strapping; requires (16) WS15-HDG nails for installation. Meets 110 codes.
STRAP TIE 3 X 7IN TRIPLE ZINC CMC PIN03NO18 Graded Rebar Pin CMC PIN04N024 Non-Graded Rebar Pin
Medium capacity; requires (20) 10d x 1-1/2" HDG nails for installation. Meets 130 codes. Reinforced bar, commonly used in concrete and masonry structures. Reinforced bar, commonly used in concrete and masonry structures.
USP Lumber T6 T-Post Strap USP Lumber ST12 Strap Tie INSUL R30K 24IN X 48IN BATT
Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Connects wood framing to resist tension forces. G90 galvanizing finish. ST Medium-duty series require 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. 16 Gauge. Kraft faced batts; "Greenguard" certified LEED eligible.
USP Lumber PB66-6TZ 1-Piece Post Cap 18 ga T USP Lumber PB 2-Piece Split Post Cap USP Lumber RS150 Coiled Strap
For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber LSTA24 Light Capacity Strap Tie USP Lumber SFP30 Fence Post Connector Gaf PFV1 Power Foundation Vent
Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Install wooden posts permanently or temporarily without digging.  For heavy-duty applications such as long runs of fencing, corner and gate posts, larger wooden gym sets, detached patio decking, wooden sidewalks, seasonal docks, and more. Removable Forcefit clamps and 2-piece construction, increases unit strength and eliminates welds which are potential weak spots. Reverse spike blades offer lateral soil resistance, increased stability, and allows driving without rotating for easy post alignment. Welded steel construction with high tech baked-on finish, rust resistant and 100% environmentally safe. Application information and installation instructions labeled on each. Green Commission finish. 13 Gauge - For 4 x 4 Posts. Polymer construction, enclosure with with steel screen. Easy installation, fits in traditional foundation vent openings with simple plug and go operation.  Effectively removes damaging excess moisture from crawl spaces and basements, while helping to prevent the growth of mold. UL and ETL Listed.
CMC PIN03N024 Rebar Pin USP Lumber T6-TZ T-Post Strap USP Lumber CPB Composite Post Base
Reinforced bar, commonly used in concrete and masonry structures. Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved.
USP Lumber WBT Flat Wall Brace USP Lumber L6TZ L-Post Strap USP Lumber EPB Elevated Post Base
For use on stud walls to resist racking during framing. Can be used to replace code prescribed 1 x 4 wood let-in bracing as a framing aid. Rolled edges and t-style design give strength, rigidity, and eliminate sharp, sheared edges. Framing aid only; Not a substitute for structural shearwall components. G90 galvanizing finish. Requires two 8d nails for each plate, one 8d nail for each stud. 511-pound max for No.WBT12. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Max load is the max load vector applied at top of stud wall section, not to exceed 25'L, resisted by the combination of wall brace straps installed. Load based on lumber with a 0.50 specific gravity and 19% or less moisture content. 22 Gauge. Medium-duty straps connect beams to posts. Requires either 1/2" bolts or 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Allows installer to pre-align posts and to preset post height above concrete floors or footings. Eliminates post-to-concrete contact for reduced moisture damage. Nails fasten to posts for carports, decks or porches. EPB is welded and primed. EBG is galvanized for added corrosion resistance. Not recommended for fence posts or unrestrained (not fixed or fastened at top) applications.. Requires (8) 16d nails for EPB4408, (12) 16d nails for EPB6608, (8) 16d HDG nails for EBG44-TZ . Meets SBCCI, BOCA - NER 505, ICBO 5736, L.A. City RR 25303 and DSA PA-076 codes. For additional information including allowable loads, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Gaf LW1 Grill Foundation Vent with Damper Lomanco PCV1 Powered Crawlspace Vent USP Lumber MSTA18-TZ Medium Capacity Strap Tie
Die-cast aluminum, grill style. Designed for nailing to floor joists or as a foundation block replacement. 8" x 16" . Quiet 110 CFM ball bearing motor. Dries crawlspace gradually. Humidity sensor. Thermostat shuts fan off at low temperatures. U.L. approved. Mounts behind foundation vent for invisible operation. Ventilates 1650 cubic feet. 8" x 16". Requires 10d nails for installation. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes.
USP Lumber PA(E) 2-Sided Post Anchor USP Lumber PA(E) 2-Sided Post Anchor TVM 2220-48-50 Double Bubble Construction Insulation
Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Safe to use; non-toxic; easy to install.  Does not require special protective clothing.  Lowers air conditioning/heating costs.  5/16? thick, multi layer, double bubble reflective insulation in rolls of various widths and lengths.  Reflects 94% of radiant heat. Class 1, Class A fire rating.  Seams should be sealed with TVM Metalized Tape for maximum effectiveness.
USP Lumber PA44-TZDP Post Anchor USP Lumber LTW12 Light Capacity Twist Strap USP Lumber PA46E-TZ Post Anchor
Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Use to tie framing members to resist tension forces as in stud plate-rim joist and truss-to-top-plate installations. Flat transition bend, for easy installation, splits total length into 2 separate, equal lengths (L1 & L2). G90 galvanizing finish. Requires an equal number of 10d or 10d x 1-1/2 fasteners at each end. Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes.
USP Lumber D Post Anchor Gaf LW1L Grill Foundation Vent with 1 3/8 in lintel and Damper USP Lumber SDJT14-TZ Deck Post Tie
Secures nominal sized post to wood surfaces offering some lateral and uplift resistance. May be used only for intermediate posts between fully anchored corner/end posts in rail system. Not Recommended for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d HDG fasteners for post and 16d HDG fasteners for base. Meets ICBO 2039 and L.A. City RR23888 codes. For additional information including allowable loads, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Designed for nailing to floor joists or as a foundation block replacement. With 1-3/8"W lintel. 8" x 16". Secures 2x joist to posts. Requires 16d HDG nails or 5/8" HDG bolts for installation. 14 Gauge.
USP Lumber T12 T-Post Strap USP Lumber MSTA24-TZ Medium Capacity Strap Tie Mutual 14640-4 Rebar Cap
Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Requires 10d nails for installation. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. OSHA rebar caps made of space age high-density polymer to protect against impalement injuries. Bright orange and fits rebar #4 - #8. Meets new OSHA requirement 344.90. Boxed.
USP Lumber C66-TZ 1-Piece Post Beam Cap USP Lumber MSTA36-TZ Medium Capacity Strap Tie USP Lumber CPB Composite Post Base
For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. One piece, designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened together to act as a unit. Requires 16d HDG nails for installation. Meets ICC-ES ESR-1280, FL11664, L.A. City RR25749 and Dade County, FL 07-0306.06 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 18 GAUGE. Requires 10d nails for installation. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved.
Gaf 500 Grate Foundation Vent with Shutter Lomanco 105W Rectangular Air-Flow Soffit Vent LL Buildsite LSV8 Rectangle Louvered Soffit Vent
Die-cast aluminum with lintel for foundation block construction. Positive open/close damper action. Lowers risk of frozen pipes, saves energy, and helps prevent foundation decay. 8" x 16". All aluminum, rust-free construction; 1" x 1/8" louvered openings; mounting flange is recessed 3/8" for soffit board. Intake ventilation for new construction or remodeling. Aluminum louvered construction. Reversible for flush or recessed mounting. Fits openings 2 inches by 8 feet. 68 sq. ins. of net free area.
Mutual 14640-3 Standard Rebar Cap USP Lumber DTB Deck Tie Bracket Billy Penn 00572 Soffit Vent
Mushroom style rebar safety caps protect from protruding rebar at construction sites. Bright colors for excellent visibility. Use where the danger of impalement is not present. Used to reinforce the connection of rail posts to a deck. Also provides lateral strength of deck-to-ledger attachment by securing deck to house framing. Installs with 1/2" anchor bolt (not included) and 8" WS15-GC Wood screws (included). G185 galvanizing finish. Pending IAPMO-ES ER-0200 and FL14500 codes. Eliminates the need for a screen. Easily installed, either flush or recessed.
USP Lumber MTW18 Medium Capacity Twist Strap USP Lumber C 1-Piece Post Cap LL Buildsite LSV8W Rectangle Louvered Soffit Vent
Use to tie framing members to resist tension forces as in stud plate-rim joist and truss-to-top-plate installations. Flat transition bend, for easy installation, splits total length into 2 separate, equal lengths (L1 & L2). G90 galvanizing finish. Requires an equal number of 10d or 10d x 1-1/2 fasteners at each end. Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. One piece, designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened together to act as a unit. Requires 16d HDG nails for installation. Meets ICC-ES ESR-1280, FL11664, L.A. City RR25749 and Dade County, FL 07-0306.06 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 18 GAUGE. Intake ventilation for new construction or remodeling. Aluminum louvered construction. Reversible for flush or recessed mounting. Fits openings 2 inches by 8 feet. 68 sq. ins. of net free area.
USP Lumber PA66-TZDP Post Anchor Lomanco 179 Foundation Vent with 3-Slide Shutter Drop-In V300 Soffit Ventilator
Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Heavy die-cast rust-free aluminum. 8" x 8" perma-coated aluminum screen attached. 3-slide shutter provides maximum ventilation. 56 square inches of net free area. 8" x 16". Designed for soffit board in miscellaneous air circulatory and moisture dispensation requirements recommended in EIFS and DEFS applications; may be combined with Starter Strip/Casing Beads or DEFS Casing Beads; vent clips are provided to connect soffit vent and assist in alignment.
Greenfiber INS541LD Low Dust Loose Fill Construction Insulation
Blow-in fiber insulation designed for loose-fill attic applications covers 40 sq. ft. at  R-19. Made of 85 percent recycled paper fibers treated for fire resistance. SCS certified and meets ASTM C-739 and ASTM E-84. For use in attics, floors, and walls of residential new construction and re-insulation applications. Provides thermal performance and sound control. Provides a barrier against air infiltration by filling gaps and voids. Dry installation only - do not add water.
   
 
1