USP Lumber JL26IF-TZ Standard Invert Flange Joist Hanger Lomanco VPLUG Foam End Plug USP Lumber JDS24 Double Shear Saddle Purlin Hanger
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Tight-fitting, high-density foam end plug. To be used in conjunction with VUR ridge vents. Designed for quick installation of purlins between rafters, joists or trusses in post and beam structures. One-piece construction assures a consistent flush fit between purlin and joist or rafter. A reinforced "double lap" seat boosts the load capacity of this heavy-duty purlin hanger. Requires (4) 10d x 1-1/2" nails for header and (4) 10d" nails for each purlin. Features a 1-9/16" top fold; pending IAPMO-ES evaluation.
USP Lumber JL28IF-TZ Standard Invert Flange Joist Hanger USP Lumber JUS210-2TZ Double Shear Slant Joint Hanger Vestal 226 Brick Lintel
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA.
Vestal 230 Brick Lintel USP Lumber SKH28R-TZ Skewed Left Joist Hanger USP Lumber SKH28L-TZ Skewed Left Joist Hanger
Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments.
Surface Protection MU2450W Regular Wound Protection Film Vestal 236 Brick Lintel Vestal 240 Brick Lintel
Multi Surface Protection Film is a self-adhering protective film for hard surfaces, such as tile, marble, granite, vinyl and VCT, laminates and factory finished hardwood. It can also be used to help prevent damage to tubs and counter tops. Ideal for remodeling, painting, moving, model home tours and parties. Green. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA.
Vestal 246 Brick Lintel Marshall JP16 Adjustable Extend-O-Post Jackpost Surface Protection CS24100 Reverse Wound Carpet Shield
Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. Protective film for all types of carpeting. Uniquely formulated adhesive system adheres to all carpet substrates. Special blend of polyethylene is highly resistant to tears or punctures. Reverse wound for easy application. Provides protection during remodeling, painting, moving, model home tours and parties. 2.5 Mil.
LL Buildsite PT-6 Replacement Thermostat Vestal 250 Brick Lintel Marshall JP36 Adjustable Extend-O-Post Jackpost
Automatic adjustable. Inline with vent. Outside arrow indicator for easy changes. Compatible with all single speed power vents. 4.4 amps, 120 VAC, 60 Hz. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension.
USP Lumber PA66R Post Anchor Vestal 260 Brick Lintel GAF Master Flow H1 Fully Adjustable Humidistat
Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA. Wires parallel to thermostat, allows moisture-laden winter air to be discharged. Thermostat will operate unit during the summer months and in the winter months humistat will takeover. Settings for humidistat are: minimum 80 percent, normal 42 percent and maximum 20 percent. Fits 2000 series.
Surface Protection CS2400L Reverse Wound Carpet Shield Marshall JP55 Adjustable Extend-O-Post Jackpost Vestal 270 Brick Lintel
Protective film for all types of carpeting. Uniquely formulated adhesive system adheres to all carpet substrates. Special blend of polyethylene is highly resistant to tears or punctures. Reverse wound for easy application. Provides protection during remodeling, painting, moving, model home tours and parties. 2.5 Mil. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA.
GAF Master Flow SGM20 Shutter Power Gable Ventilator Acorn NSR3418 Round Nail Stake USP Lumber JL24 Standard Joist Hanger
Use with all attic power gable mount vents; moving air opens the louvers only when the power vent is operating; when vent is off, shutter helps prevent infiltration of rain , snow, insects, etc.; maintenance-free white aluminum construction; can be painted if desired. Used for securing wood and metal forms to the ground in all flatwork applications, for attaching screed bard holder clamps, for securing landscape timbers, surveying stakes, string line guides, etc. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Gaf Master Flow ARSBL Joint Strap Gaf Master Flow ARSBR Joint Strap Vestal CL-2424 Foundation Access Door
Joint straps for AR10 series aluminum ridge vent. Miami Dade County Approved #NOA 99-0422.04. Nos.ARSBLF, ARSBRF, & ARSWHF Florida Building Code (FBC) Approved FL 5027. Joint straps for AR10 series aluminum ridge vent. Miami Dade County Approved #NOA 99-0422.04. Nos.ARSBLF, ARSBRF, & ARSWHF Florida Building Code (FBC) Approved FL 5027. Heavy gauge steel, all welded construction. Built-in lintel attached. Positive latch made to accept padlock. Door size is stenciled on each door. Primed with black corrosion resistant paint. Made in USA.
USP Lumber JL26 Standard Joist Hanger Surface Protection FS24200L Reverse Wound Protection Film Vestal CL-2416 Foundation Access Door
G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Multi Surface Protection Film is a self-adhering protective film for hard surfaces, such as tile, marble, granite, vinyl and VCT, laminates and factory finished hardwood. It can also be used to help prevent damage to tubs and counter tops. Ideal for remodeling, painting, moving, model home tours and parties. Green. Heavy gauge steel, all welded construction. Built-in lintel attached. Positive latch made to accept padlock. Door size is stenciled on each door. Primed with black corrosion resistant paint. Made in USA.
Vestal CL-3216 Foundation Access Door Marshall JP79 Adjustable Extend-O-Post Jackpost Lomanco HUMID Humidistat
Heavy gauge steel, all welded construction. Built-in lintel attached. Positive latch made to accept padlock. Door size is stenciled on each door. Primed with black corrosion resistant paint. Made in USA. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. Allows user to control moisture and humidity levels during colder months. Adjustable to fit individual attic humidity levels. Wires parallel with existing thermostat.
Marshall JP84 Adjustable Extend-O-Post Jackpost Vestal CL-3224 Foundation Access Door Acorn NSR3424 Round Nail Stake
Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. Heavy gauge steel, all welded construction. Built-in lintel attached. Positive latch made to accept padlock. Door size is stenciled on each door. Primed with black corrosion resistant paint. Made in USA. Used for securing wood and metal forms to the ground in all flatwork applications, for attaching screed bard holder clamps, for securing landscape timbers, surveying stakes, string line guides, etc.
USP Lumber JUS28 Double Shear Slant Joist Hanger Quarrix Building Products 58784 Ridge Vent Diversi-Plast 58786 Ridge Vent
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Use under asphalt shingles, metal roofing, cedar shakes or slate; virtually invisible with low-profile design; no baffle to collect debris or clog; HDPE crush-resistant material; adapts to roof pitches 3/12 to 20/12; certified by ICC, BOCA, ICBO, UL CLASS A or C, TDI and Miami Dade county. Use under asphalt shingles, metal roofing, cedar shakes or slate; virtually invisible with low-profile design; no baffle to collect debris or clog; HDPE crush-resistant material; adapts to roof pitches 3/12 to 20/12; certified by ICC, BOCA, ICBO, UL CLASS A or C, TDI and Miami Dade county.
Diversi-Plast 58785 Ridge Vent LL Buildsite PVM105/110 Replacement Motor USP Lumber PCP Post Cap
Use under asphalt shingles, metal roofing, cedar shakes or slate; virtually invisible with low-profile design; no baffle to collect debris or clog; HDPE crush-resistant material; adapts to roof pitches 3/12 to 20/12; certified by ICC, BOCA, ICBO, UL CLASS A or C, TDI and Miami Dade county. Replacement motor for GM30, PG1, PG2, MD105, MD105D, H122D, PR1, PR1D, PR2D, PR2DHT, EGV5, ERV4 & ERV5 series power vents. Seamless, keeps water off post tops to protect wood from moisture damage. Corrosion-proof and paintable. Requires one 8d HDG or 10d HDG nail for installation. 3-5/8"W - For 4 x 4 Post/Column.
STAKE NAIL ROUND 3/4X30IN     Vestal CL-3232 Foundation Access Door USP Lumber JL28 Standard Joist Hanger
STAKE NAIL ROUND 3/4X30IN
Our Price: $65.28
Used for securing wood and metal forms to the ground in all flatwork applications, for attaching screed bard holder clamps, for securing landscape timbers, surveying stakes, string line guides, etc. Heavy gauge steel, all welded construction. Built-in lintel attached. Positive latch made to accept padlock. Door size is stenciled on each door. Primed with black corrosion resistant paint. Made in USA. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Lomanco PVMTR Replacement Motor Cobra 2005 Shingle Over Coil Ridge Vent USP Lumber PL4 Protection Plate
Replacement motor (model FO510B2944) for the LomanCool 2000/1800 power vent.  Replaces  previous motors with the following model numbers: AO416B2059, AO510B2389 and FO510B2497. A universal mounting hardware kit comes in the box with each motor. Motor replacement does not include blade, conduit or thermostat. Motor specifications: 3.4 Amps, 1/10 HP, 1100 RPM and 120 Volts. Use on roof pitches from 3/12 to 20/12. Helps remove excess heat and moisture to protect against premature roof deterioration and helps prevent problems with birds, insects and animals in attic. Prevents roof rot in attic or roof deck. Minimizes peeling and extends the life of exterior and interior paint. Limits mold growth. Easy to install, shingle over design is virtually invisible when installed. Includes "Smart Nails" for hand-nailing, or 1-3/4" coil nails for nail guns. Meets or exceeds all code requirements. 16.9 sq. ins. per linear foot of net free ventilating area when hand-nailed. 14.1 sq. ins. per linear foot of net free ventilating area when using nail gun. Will not crack or dent during installation. Won't corrode, rust, or turn brittle. Works with traditional size ridge cap shingles. Easy-to-install for protecting plumbing and power or communication wiring from screw or nail penetration. Conforms to National Electric Code. 16 Gauge - 1/16" Thickness.
Marshall JP84HD Adjustable Extend-O-Post Jackpost USP Lumber JUS28-TZ Double Shear Slant Joint Hanger USP Lumber CPB Composite Post Base
Use for supporting sagging floors, weak beams and warping stairways. 2-1/2" x 14 gauge prime steel inner tubing. 2-3/4" x 14 gauge prime steel outer tubing. 2-1/2" steel collar. 1-1/4" x 6" steel screw. Two 4" x 6" x 7 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved.
USP Lumber JUS210 Double Shear Slant Joist Hanger Marshall AC363/3637 Adjustable Round Column Lomanco LPLUG End Plug
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Tight-fitting, high-density foam end plug. To be used in conjunction with LPR ridge vents.
USP Lumber JL210 Standard Joist Hanger STAKE NAIL ROUND 3/4X36IN     Marshall AC369/3691 Adjustable Round Column
STAKE NAIL ROUND 3/4X36IN
Our Price: $78.85
G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Used for securing wood and metal forms to the ground in all flatwork applications, for attaching screed bard holder clamps, for securing landscape timbers, surveying stakes, string line guides, etc. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145.
HANGER RIDGE RAFTER 18 GAUGE  Marshall AC386 Adjustable Round Column Marshall AC370/3704 Adjustable Round Column
Supports rafter pitches up to 7:12 (30?). Nesting top flange for installation on 2x support beams. Use all specified fasteners. The rafter end at the ridge must be plumb cut to achieve published loads. Optional diamond nail holes can be used to faster RR to end of rafter before settling rafter into place. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145.
Marshall AC373/3737 Adjustable Round Column USP Lumber JUS24 Double Shear Slant Joist Hanger Marshall AC390 Adjustable Round Column
3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145.
VENT ROOF MOUNT 1000CFM MILL  Marshall AC376/3760 Adjustable Round Column USP Lumber KNS1 Protection Plate
Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Easy to install for protecting plumbing and power or communication wiring from screw or nail penetration. 16 gauge, 1/16" thick. Conforms to National Electric Code.
Marshall AC379/3791 Adjustable Round Column VENT ROOF 1000CFM WEATHER WOOD VENT ROOF MOUNT 1000CFM BLACK
3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation. Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation.
Marshall AC380/3804 Adjustable Round Column Marshall AC383/3837 Adjustable Round Column FAN GABLE MOUNT ATTIC 1450 CFM
3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Energy efficient PSC (permanent-split capacitor) helps to reduce energy costs and helps prolong life of the roof and shingles; rust-resistant metal for durability; mounts in the gable inside the attic; adjustable thermostat included; mounting brackets included for installation and optional humidistat available (H1) - sold separately.
USP Lumber JUS24-TZ Double Shear Slant Joint Hanger USP Lumber PB66-6TZ 1-Piece Post Cap 18 ga T USP Lumber PB 2-Piece Split Post Cap
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Gaf Master Flow ARCP End Plug/Connector Add-A-Vent 1800 Gable Ventilator USP Lumber JUS26 Double Shear Slant Joist Hanger
For all AR10 series ridge vent. All aluminum construction. Balanced blades pitched for smooth operation and high volume air removal. Five blades with 12" diameter. Factory-set adjustable thermostat (switches on at 100 degrees and off at 85 degrees). Thermostat features a "push to test" button. Can be mounted in horizontal or vertical positions on either 16" or 24" center framing members. Designed to mount behind existing gable louver. Motor: 1/10 HP; 1100 RPM; 3.4 Amps; 120 Volts. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber FB24-TZ Fence Bracket USP Lumber JUS26-TZ Double Shear Slant Joint Hanger Lo-OmniRoll LOR-30 Ridge Vent
Provides stronger fence connections and simplifies fence assembly. Can be installed before posts are set to help ensure uniform spacing and alignment. Requires five 6d HDG fasteners for rails and three 8d HDG fasteners for posts. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Can be installed with a pneumatic nail gun or hammer. Two coils of 1-3/4" nails provided. External convolute baffles - incurved design allows flexibility to roll up and out while maintaining its shape. Can be cut at one foot intervals - multiple cut lines eliminates unnecessary scrap. Weather protection and performance with no filter to clog. Molded fanfold end plug. Molded centerline. Nail holes marked every 6" - supported every foot. 11 square inches of net free ventilating area per lineal foot. External venturi baffle. Adjusts from 2/12 to 16/12 roof pitches. Limited lifetime warranty- the engineered material guarantees it will last as long as your shingles. Miami Dade County Approved 13-0701.11. 52 CFM at wind velocity of 3 MPH; 148 CFM at wind velocity of 8 MPH; 283 CFM at wind velocity of 15 MPH.
VENT ROOF 1250CFM WEATHER WOOD VENT ROOF MOUNT 1250CFM BLACK USP Lumber JUS210-TZ Double Shear Slant Joint Hanger
Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation. Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JUS26-2 Double Shear Slant Support Joist Hanger Proshield PS3250 Absorbent Mat USP Lumber SFP30 Fence Post Connector
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ultra-strong surface protection. Keeps your job site floors and counters safe from damage and debris. Pro Shield is the ultimate reusable surface protector for the professional. Protects hardwood, ceramic tile, linoleum, carpet surfaces, marble, granite, other counter surfaces, sinks and tubs during building and remodeling. Slip-resistant and provides a safer work environment; rolls are easy to install and carry from site to site and can be cut to fit any space and works well on either side; vacuum or sweep clean. Great for movers. Install wooden posts permanently or temporarily without digging.  For heavy-duty applications such as long runs of fencing, corner and gate posts, larger wooden gym sets, detached patio decking, wooden sidewalks, seasonal docks, and more. Removable Forcefit clamps and 2-piece construction, increases unit strength and eliminates welds which are potential weak spots. Reverse spike blades offer lateral soil resistance, increased stability, and allows driving without rotating for easy post alignment. Welded steel construction with high tech baked-on finish, rust resistant and 100% environmentally safe. Application information and installation instructions labeled on each. Green Commission finish. 13 Gauge - For 4 x 4 Posts.
Cobra lll CRV3 Shingle Over Ridge Vent FAN GABLE MOUNT ATTIC 1600 CFM Cobra Snow Country 2027000CU Ridge Vent
Shingle-over to blend into ridge line. Allows heat/condensation to escape at most effective location. Watertight, passes 110-MPH wind-driven rain test. External baffles help deflect wind/rain, no end caps needed. Prevents roof rot in attic or roof deck. Minimize peeling and extend the life of exterior and interior paint. Limit mold growth. Specially-designed louver spacing helps keep insects out. Energy-efficient, crush-resistant, with internal structural support for added durability. Extra-flexible hinge design for installation on 3:12 to 16:12 sloped roofs. 3" ring shank nails included to insure proper fastening. Edge overhang for smooth, continuous coverage between sections. Provides 18 sq.in/linear foot net-free ventilating area. 40' replaces 18 conventional or ten 12" turbine roof vents. Hip/ridge compatible with traditional sizes (11-1/2 x 12"). "EasyTear" feature allows product to be hand-torn in 3" increments. Boxed. Energy efficient PSC (permanent-split capacitor) helps to reduce energy costs and helps prolong life of the roof and shingles; rust-resistant metal for durability; mounts in the gable inside the attic; adjustable thermostat included; mounting brackets included for installation and optional humidistat available (H1) - sold separately. Helps resist snow infiltration in harsh winter climates. Prevent roof rot in attic or roof deck. Minimize peeling and extend the life of exterior and interior paint. Limits mold growth. Allows heat/condensation to escape at most effective location. Shingle-over design blends into ridge line. Watertight, passes 110-MPH wind-driven rain test. External baffles help deflect wind/rain, no end caps needed. 1/8" louver spacing helps keep insects out. Energy-efficient, crush-resistant, with internal structural support for added durability. Flexible 3-point hinge for installation on 3:12 to 16:12 sloped roofs. 40' replaces 18 conventional or ten 12" turbine roof vents. Quick alignment, special tabs for easy, reliable connection. No overdrive, reinforced nail holes. "EasyTear" feature allows product to be hand-torn in 3" increments. Edge overhang allows smooth, continuous coverage between sections. Provides 18 sq.in/linear foot net-free ventilating area. Works with traditional size ridge cap shingles. Boxed.
USP Lumber CPB Composite Post Base Lomancool 2000 2000 Standard Roof Mount Power Ventilator Lomancool 2000 2000BR Standard Roof Mount Power Ventilator
Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved. All-aluminum construction. Deep drawn flange and rain shield keep water out. Factory-set adjustable thermostat switches on at 100 degrees and off at 85 degrees Fahrenheit. Thermostat features a "push to test" button. Balanced fan blades for quiet operation. 8" x 8" aluminum screen attached for increased protection. 20" x 23" base plate. Features 12" diameter blade. 3.4 Amp, 120 Volt, 1100 RPM motor. 16-0510.25 Miami Dade County approved. All-aluminum construction. Deep drawn flange and rain shield keep water out. Factory-set adjustable thermostat switches on at 100 degrees and off at 85 degrees Fahrenheit. Thermostat features a "push to test" button. Balanced fan blades for quiet operation. 8" x 8" aluminum screen attached for increased protection. 20" x 23" base plate. Features 12" diameter blade. 3.4 Amp, 120 Volt, 1100 RPM motor. 16-0510.25 Miami Dade County approved.
Lomancool 2000 2000B Standard Roof Mount Power Ventilator USP Lumber TFL2595 Joist Hanger Lomancool 2000 2000WB Standard Roof Mount Power Ventilator
All-aluminum construction. Deep drawn flange and rain shield keep water out. Factory-set adjustable thermostat switches on at 100 degrees and off at 85 degrees Fahrenheit. Thermostat features a "push to test" button. Balanced fan blades for quiet operation. 8" x 8" aluminum screen attached for increased protection. 20" x 23" base plate. Features 12" diameter blade. 3.4 Amp, 120 Volt, 1100 RPM motor. 16-0510.25 Miami Dade County approved. Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1831 codes. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge. All-aluminum construction. Deep drawn flange and rain shield keep water out. Factory-set adjustable thermostat switches on at 100 degrees and off at 85 degrees Fahrenheit. Thermostat features a "push to test" button. Balanced fan blades for quiet operation. 8" x 8" aluminum screen attached for increased protection. 20" x 23" base plate. Features 12" diameter blade. 3.4 Amp, 120 Volt, 1100 RPM motor. 16-0510.25 Miami Dade County approved.
USP Lumber EPB Elevated Post Base USP Lumber JUS26-2TZ Double Shear Slant Joint Hanger USP Lumber JUS210-2 Double Shear Slant Support Joist Hanger
Allows installer to pre-align posts and to preset post height above concrete floors or footings. Eliminates post-to-concrete contact for reduced moisture damage. Nails fasten to posts for carports, decks or porches. EPB is welded and primed. EBG is galvanized for added corrosion resistance. Not recommended for fence posts or unrestrained (not fixed or fastened at top) applications.. Requires (8) 16d nails for EPB4408, (12) 16d nails for EPB6608, (8) 16d HDG nails for EBG44-TZ . Meets SBCCI, BOCA - NER 505, ICBO 5736, L.A. City RR 25303 and DSA PA-076 codes. For additional information including allowable loads, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber PA(E) 2-Sided Post Anchor USP Lumber TFL20118 Joist Hanger USP Lumber JUS28-2 Double Shear Slant Joist Hanger
Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Features 1-1/2" top flange depth that accommodates all header types as well as bact-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1831. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2" nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber PA(E) 2-Sided Post Anchor USP Lumber TFL25118 Joist Hanger USP Lumber PA44-TZDP Post Anchor
Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1831 codes. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge. Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes.
Surface Protection CS24500 Reverse Wound Carpet Shield VENT ROOF 1500CFM WEATHER WOOD Lomanco OR4 Ridge Vent
Protective film for all types of carpeting. Uniquely formulated adhesive system adheres to all carpet substrates. Special blend of polyethylene is highly resistant to tears or punctures. Reverse wound for easy application. Provides protection during remodeling, painting, moving, model home tours and parties. 2.5 Mil. Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation. Internal aerodynamic curved baffles. 18 square inches of net free ventilating area per lineal foot. External perpendicular omni baffles. Weatherproof under-lapping joint. Four drain holes per foot per side. External venturi baffle. Pre-formed to 3/12 pitch. 10 supported nail holes.  Alignment tabs. External water shield. Slot width guide lines. Adjusts from 2/12 to 16/12 roof pitches. Co-polymer materials. Limited lifetime warranty- the engineered material guarantees it will last as long as your shingles. No connectors required. Molded fanfold end plugs - no accessories or alterations needed. Miami Dade County Approved 16-0510.27. 95 CFM at wind velocity of 3 MPH; 235 CFM at wind velocity of 8 MPH; 430 CFM at wind velocity of 15 MPH; OR4 with nails and OR4 with screen available.
USP Lumber PA46E-TZ Post Anchor USP Lumber D Post Anchor Lomancool 2000 2000BTH Standard Roof Mount Power Ventilator
Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Secures nominal sized post to wood surfaces offering some lateral and uplift resistance. May be used only for intermediate posts between fully anchored corner/end posts in rail system. Not Recommended for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d HDG fasteners for post and 16d HDG fasteners for base. Meets ICBO 2039 and L.A. City RR23888 codes. For additional information including allowable loads, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. All-aluminum construction. Deep drawn flange and rain shield keep water out. Factory-set adjustable thermostat switches on at 100 degrees and off at 85 degrees Fahrenheit. Thermostat features a "push to test" button. Humidistat allows moisture and humidity levels to be controlled during colder months. Balanced fan blades for quiet operation. 8" x 8" aluminum screen attached for increased protection. 20" x 23" base plate. Features 12" diameter blade. 3.4 Amp, 120 Volt, 1100 RPM motor.
Lomancool 2000 2000TH Standard Roof Mount Power Ventilator Diversi-Plast 59092 Ridge Vent Lo-OmniRidge LOR9-4 Ridge Vent
All-aluminum construction. Deep drawn flange and rain shield keep water out. Factory-set adjustable thermostat switches on at 100 degrees and off at 85 degrees Fahrenheit. Thermostat features a "push to test" button. Humidistat allows moisture and humidity levels to be controlled during colder months. Balanced fan blades for quiet operation. 8" x 8" aluminum screen attached for increased protection. 20" x 23" base plate. Features 12" diameter blade. 3.4 Amp, 120 Volt, 1100 RPM motor. Use under asphalt shingles, metal roofing, cedar shakes or slate; virtually invisible with low-profile design; no baffle to collect debris or clog; HDPE crush-resistant material; adapts to roof pitches 3/12 to 20/12; certified by ICC, BOCA, ICBO, UL CLASS A or C, TDI and Miami Dade county. Can be installed with a pneumatic nail gun or hammer. Internal aerodynamic curved baffles. External perpendicular omni baffles. Weatherproof underlapping joint. Four drain holes per foot per side. 11 square inches of net free ventilating area per lineal foot. External venturi baffle. Adjusts from 2/12 to 16/12 roof pitches. Limited lifetime warranty- the engineered material guarantees it will last as long as your shingles. Nail holes marked every 6" - supported every foot. Molded nail lines and centerline. Alignment tabs. External water shield. Slot width guide lines. Molded fanfold end plug. Miami Dade County Approved 13-0701.10. 52 CFM at wind velocity of 3 MPH; 148 CFM at wind velocity of 8 MPH; 283 CFM at wind velocity of 15 MPH.
USP Lumber SDJT14-TZ Deck Post Tie USP Lumber JUS26-GC Double Shear Slant Joist Hanger Step N Peel DG30W Floor Mat
Secures 2x joist to posts. Requires 16d HDG nails or 5/8" HDG bolts for installation. 14 Gauge. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Film mat with a tacky surface to remove dust and dirt from footwear. Features a sturdy, re-usable platform constructed of a rigid polystyrene, with a nonskid backing that holds it securely to floor surfaces like carpeting, tile, concrete and more. Each mat contains 30 tabbed layers of film. White on white Frame.
USP Lumber C66-TZ 1-Piece Post Beam Cap Surface Protection CS2130W Carpet Shield USP Lumber JDS24-S Double Shear Single Purlin Hanger
For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. One piece, designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened together to act as a unit. Requires 16d HDG nails for installation. Meets ICC-ES ESR-1280, FL11664, L.A. City RR25749 and Dade County, FL 07-0306.06 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 18 GAUGE. Carpet Shield clear, self adhering film protects all types of carpeting for up to 45 days without leaving any adhesive residue. Highly resistant to tears or punctures. Carpet Shield's non-slip surface is ideal during remodeling, painting and moving; helps minimize clean-up time and damage claims. No tape required. Available in a variety of sizes; the larger rolls are reverse-wound for faster application. Designed for quick installation of purlins between rafters, joists or trusses in post and beam structures. One-piece construction assures a consistent flush fit between purlin and joist or rafter. A reinforced "double lap" seat boosts the load capacity of this heavy-duty purlin hanger. Requires (2) 10d x 1-1/2"nails for header and (2) 10d nails for each purlin. Features a 3/4" top fold; pending IAMPO-ES evaluation.
USP Lumber ICPL58-TZ Protection Plate USP Lumber ICPL516-TZ Protection Plate Surface Protection CS36500 Reverse Wound Carpet Shield
Easy-to-install plates protect plumbing and power/communication wiring from nail or screw penetration. 16 Gauge - 1/16" Thickness. Easy-to-install plates protect plumbing and power/communication wiring from nail or screw penetration. 16 Gauge - 1/16" Thickness. Protective film for all types of carpeting. Uniquely formulated adhesive system adheres to all carpet substrates. Special blend of polyethylene is highly resistant to tears or punctures. Reverse wound for easy application. Provides protection during remodeling, painting, moving, model home tours and parties. 2.5 Mil.
USP Lumber THF25112 Joist Hanger USP Lumber CPB Composite Post Base USP Lumber LSSH15-TZ Slope/Skew Joist Hanger
Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degree angle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved. Connects rafters to ridge beams in vaulted roof structures; field adjustable to meet a variety of skew and slope applications; slopes to any pitch to 45 degrees up or down and skews up to 45 degrees right or left.  For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber JUS28-2TZ Double Shear Slant Joist Hanger USP Lumber SKH28L Skewed Left Joist Hanger USP Lumber SKH28R Skewed Right Joist Hanger
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments.
USP Lumber DTB Deck Tie Bracket USP Lumber C 1-Piece Post Cap GAF Master Flow PRSOLAR Solar Powered Roof Ventilator
Used to reinforce the connection of rail posts to a deck. Also provides lateral strength of deck-to-ledger attachment by securing deck to house framing. Installs with 1/2" anchor bolt (not included) and 8" WS15-GC Wood screws (included). G185 galvanizing finish. Pending IAPMO-ES ER-0200 and FL14500 codes. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. One piece, designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened together to act as a unit. Requires 16d HDG nails for installation. Meets ICC-ES ESR-1280, FL11664, L.A. City RR25749 and Dade County, FL 07-0306.06 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 18 GAUGE. Galvanized steel construction. Works with existing soffit intake vents to help remove damaging heat and moisture from the attic. More effective than roof louvers or turbine style vents. Helps prevent wood rot and extend the life of exterior paint. Eliminates related utility cost.  Passes 110 mph wind-driven rain test. Power source - DC motor w/10 watt Solar panel, tested to withstand hail and foreign object impact for long-lasting operation. Brushless motor lasts up to ten times longer than traditional motors. Airflow (Cubic Ft. Per Min.) 500. Tilt and swivel design for optimal solar exposure. Extra-wide flashing helps prevents leaks. Includes remote solar panel mounting system.
USP Lumber SKH26R-TZ Skewed Right Joist Hanger USP Lumber SKH26L-TZ Skewed Left Joist Hanger USP Lumber PA66-TZDP Post Anchor
Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes.
Gaf Master Flow AR10BLH Ridge Vent Gaf Master Flow AR10BRH Ridge Vent Lomanco LPR10B Ridge Vent
Maintenance-free all aluminum, aerodynamic profile. Built-in weather baffle, extra wide free flow drainage areas, pre-punched nail holes. Design helps prevent insect, rain and snow infiltration. Base adjustable to broad range of roof pitch 3/12 - 8/12. Dade County Approved 02-0524.01. Nos.AR10BLF, AR10BRF, & AR10WHF Florida Building Code (FBC) Approved FL5027. Maintenance-free all aluminum, aerodynamic profile. Built-in weather baffle, extra wide free flow drainage areas, pre-punched nail holes. Design helps prevent insect, rain and snow infiltration. Base adjustable to broad range of roof pitch 3/12 - 8/12. Dade County Approved 02-0524.01. Nos.AR10BLF, AR10BRF, & AR10WHF Florida Building Code (FBC) Approved FL5027. One-piece construction. 3/8" x 1/2" slotted weep holes in wind baffles for water run-off. 1/8" x 1" louvered openings inverted to block weather infiltration. Can be cut to desired length at 2-foot intervals. Pre-notched nail holes. 2" wide nailing flange. Male/female connections - no straps necessary. Adjustable from 3/12 to 12/12 roof pitches. 18 square inches of net free ventilating area per lineal foot. Miami Dade County Approved 16-0510.24. 43 CFM at wind velocity of 3 MPH; 117 CFM at wind velocity of 8 MPH; 221 CFM at wind velocity of 15 MPH.
Lomanco LPR10BR Ridge Vent
One-piece construction. 3/8" x 1/2" slotted weep holes in wind baffles for water run-off. 1/8" x 1" louvered openings inverted to block weather infiltration. Can be cut to desired length at 2-foot intervals. Pre-notched nail holes. 2" wide nailing flange. Male/female connections - no straps necessary. Adjustable from 3/12 to 12/12 roof pitches. 18 square inches of net free ventilating area per lineal foot. Miami Dade County Approved 16-0510.24. 43 CFM at wind velocity of 3 MPH; 117 CFM at wind velocity of 8 MPH; 221 CFM at wind velocity of 15 MPH.
   
 