Home > HARDWARE > CONSTRUCTION HARDWARE > JOIST HANGERS & CONNECTORS
Choose a sub category:
JOIST HANGERS FRAMING ANGLES/ANCHORS MENDING PLATES
NAIL PLATES POST ANCHORS / CAPS FENCE BRACKETS
BRIDGING INSULATION SUPPORTS STRAPS
PLYWOOD CLIPS FOUNDATION ANCHORS BRICK/WALL TIES
MISC CONSTR HARDWARE
Sort By:
1
USP Lumber JL26IF-TZ Standard Invert Flange Joist Hanger USP Lumber JDS24 Double Shear Saddle Purlin Hanger USP Lumber JL28IF-TZ Standard Invert Flange Joist Hanger
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Designed for quick installation of purlins between rafters, joists or trusses in post and beam structures. One-piece construction assures a consistent flush fit between purlin and joist or rafter. A reinforced "double lap" seat boosts the load capacity of this heavy-duty purlin hanger. Requires (4) 10d x 1-1/2" nails for header and (4) 10d" nails for each purlin. Features a 1-9/16" top fold; pending IAPMO-ES evaluation. Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JUS210-2TZ Double Shear Slant Joint Hanger Stanley 316489 Weldable Rebar Quik-Tube 6922-01 Building Form
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Stanley Weldable Rebar, 1/2 in, NO 4 Nominal, 36 in Overall Length, Steel Used by homeowners and residential contractors to create everything from lamp post and mailbox bases to deck supports. Easy-to-use cardboard tube, scaled-down version of rigid fiber forms that heavy-construction contractors use. Pour concrete in form, let it dry, then cut away form. Length can be cut down if needed.
Stanley 346965 Weldable Rebar TAPE SEAM BUILDER 3INX180FT   Quikrete 6922-02 Concrete Quik-Tube Form
Stanley Weldable Rebar, 1/2 in, NO 4 Nominal, 4 ft Overall Length, Steel, Used in Landscaping Has an aggressive, high tack adhesive that can seam Builder Board together for months; strong, flexible and lays flat. Used by homeowners and residential contractors to create everything from lamp post and mailbox bases to deck supports. Easy-to-use cardboard tube, scaled-down version of rigid fiber forms that heavy-construction contractors use. Pour concrete in form, let it dry, then cut away form. Length can be cut down if needed.
RH Tamlyn PC1532 Plywood Clip GAF Master Flow IR61 Slant Back Super Low Profile Roof Louver Duraflo 6050G Square Top Type B Roof Ventilator
With built-in spacer for use when support spacing exceeds the maximum length of an unsupported edge. Boxed. Just 2"H for better appearance. Injection-molded, high-impact resin construction for long life. Colors complement most roofs. Pre-drilled nail holes make installation easier. 11-3/4" x 9-3/4" opening, 18-1/2" x 17-1/2" flashing, 4-1/4"H, 37 sq.in. of net free ventilating area. Low profile style. Molded in screen. Angled screen that prevents birds from nesting. Wide, flexible flange will not crack on installation, even in cold weather. Angled throat to effectively deflect water. Injection molded UV resistant ploypropylene.
Duraflo 6050BL Square Top Type B Roof Ventilator Duraflo 6050BR Square Top Type B Roof Ventilator Stanley 316497 Weldable Rebar
Low profile style. Molded in screen. Angled screen that prevents birds from nesting. Wide, flexible flange will not crack on installation, even in cold weather. Angled throat to effectively deflect water. Injection molded UV resistant ploypropylene. Low profile style. Molded in screen. Angled screen that prevents birds from nesting. Wide, flexible flange will not crack on installation, even in cold weather. Angled throat to effectively deflect water. Injection molded UV resistant ploypropylene. Stanley Weldable Rebar, 1/2 in, NO 4 Nominal, 72 in Overall Length, Steel, Used in Landscaping
RH Tamlyn PCS716 Plywood Clip RH Tamlyn PCS12 Plywood Clip RH Tamlyn PCS1532 Plywood Clip
Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed.
Quik-Tube 6922-03 Building Form USP Lumber SKH28R-TZ Skewed Left Joist Hanger USP Lumber SKH28L-TZ Skewed Left Joist Hanger
Used by homeowners and residential contractors to create everything from lamp post and mailbox bases to deck supports. Easy-to-use cardboard tube, scaled-down version of rigid fiber forms that heavy-construction contractors use. Pour concrete in form, let it dry, then cut away form. Length can be cut down if needed. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments.
Duraflo 6065BL Slant Back Roof Ventilator Duraflo 6065BR Slant Back Roof Ventilator Trimaco 35140 Economy Builder Paper
Polypropylene material. Ideal for steep pitched roofs. Low profile and a stair step screen to provide more airflow in a smaller vent. 17.5" x 18.5" flashing with 4.3" height. 61 square inches of net free area. UV resistant polypropylene. Polypropylene material. Ideal for steep pitched roofs. Low profile and a stair step screen to provide more airflow in a smaller vent. 17.5" x 18.5" flashing with 4.3" height. 61 square inches of net free area. UV resistant polypropylene. Use as a paint dropcloth and runner, floor protection, garden weed control, for arts and crafts projects, or wrapping paper. Brown.
Squeek No More 1011345 Screw Set RH Tamlyn PCS58 Plywood Clip Trimaco 35145/64 Regular Weight Rosin Paper
Specially scored waxed screws. Scored head breaks off at the same place every time. Carded. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Used as a temporary and disposable general purpose work-over paper to protect surfaces from foot traffic, wall and ceiling texture overspray and paint drippings. Also used in many residential and commercial construction applications as separation sheets between other building products. Sized to resist bleeding and offer moisture protection. 501 square feet per roll. Red.
Trimaco L3536144 Rosin Paper Acorn IHW16100 Insulation Support Wire 16 in L Trimaco 36144 Construction Paper
Use as a paint dropcloth and runner, floor protection, garden weed control, for arts and crafts projects, or wrapping paper. 432 square feet per roll. Brown. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. Laminated with high tech fiber coating. Protects floors from paint, equipment, construction materials, and foot traffic. Ideal for protecting carpets, ceramic tile, hardwood, concrete, brick, and vinyl. Has superior moisture hold out and avoids tears. Shields and cushions surfaces. Over 50 percent heavier than regular rosin paper. Use brown on the top and white on the bottom. Brown.
FORM CONCRETE FOOT PLASTC 22IN USP Lumber NA11-5MC Joist Hanger Nail USP Lumber NA9-5MC Joist Hanger Nail
Fastest, easiest way to form concrete footings; patented square footing form decreases cycle time, labor and material cost; can be sized, attached to construction tube, placed in excavated hole and backfilled. Can be used with rebar to reinforce footing or column if needed. Structurally rated. For use with MiTek/USP Lumber Connectors' products. For additional information including withdrawal load and allowable shear per nail, please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Structurally rated. For use with MiTek/USP Lumber Connectors' products. For additional information including withdrawal load and allowable shear per nail, please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Squeek No More 1010543 Floor Squeak Repair Kit Marshall JP16 Adjustable Extend-O-Post Jackpost FORM CONCRETE FOOT PLASTC 28IN
Eliminate squeaks quickly and permanently. Can be applied to 2nd floors, hardwood floors, carpet, and stairs. Each kit contains: 1 - alignment and depth control fixture, 50 - specially scored waxed screws, 1 - special driver bit, 1 - complete instruction kit. Carded. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. Fastest, easiest way to form concrete footings; patented square footing form decreases cycle time, labor and material cost; can be sized, attached to construction tube, placed in excavated hole and backfilled. Can be used with rebar to reinforce footing or column if needed.
Acorn IHW24100 Insulation Support Wire 24 in L Deckmate 90166 Deck Bench Bracket with Bench Bracket USP Lumber RS20-R Coiled Strap
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. You determine the size. Connect with railing brackets with 2x4 and 2x6 lumber to easily add a bench to any size or shape deck. Gain increased seating area while using only 7" of deck space. Assembled unit stands 36"H for deck railing, seat is 17"H. Quick and easy to assemble using basic tools. Includes bench bracket, hardware and instructions. LUMBER NOT INCLUDED. Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
LL Buildsite PT-6 Replacement Thermostat ANGLE 2X4IN TRIPLE ZINC 12GA  Acorn IHW16500 Insulation Support Wire 16 in L
Automatic adjustable. Inline with vent. Outside arrow indicator for easy changes. Compatible with all single speed power vents. 4.4 amps, 120 VAC, 60 Hz. Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge.
GAF Master Flow GT12E External Braced Deluxe Turbine Head Marshall JP36 Adjustable Extend-O-Post Jackpost USP Lumber PA66R Post Anchor
Fits most brands of turbine bases. No.GT12E Dade County Approval 04-0618.01. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes.
RH Tamlyn BT 22SP Corrugated Straight Brick Wall Tie RH Tamlyn BT22ZZSP Corrugated Scalloped Zig Zag Brick Wall Tie GAF Master Flow H1 Fully Adjustable Humidistat
Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Boxed. Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Wires parallel to thermostat, allows moisture-laden winter air to be discharged. Thermostat will operate unit during the summer months and in the winter months humistat will takeover. Settings for humidistat are: minimum 80 percent, normal 42 percent and maximum 20 percent. Fits 2000 series.
Marshall JP55 Adjustable Extend-O-Post Jackpost RH Tamlyn BT28ZZ5SP Corrugated Scalloped Zig Zag Brick Wall Tie RH Tamlyn BT28500SP Corrugated Straight Brick Wall Tie
Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Boxed.
GAF Master Flow AIC12 Internal Braced Rotary Turbine Ventilator ANGLE 2X6IN TRIPLE ZINC 12GA  GAF Master Flow GIC12 Internal Braced Rotary Turbine Ventilator
Permanently lubricated track system, upper and lower stainless steel ball bearings prevents metal-to-metal contact, encased to help prevent dirt, dust, sand, and other foreign materials from damaging bearings for long life, less friction, smoother spin, and wear resistance. Heavy-duty steel spider braces and case-hardened steel shaft for long-lasting strength/durability. Simple, mechanically-locked, 2-piece head/base for faster, easier installation. Pre-punched bottom/crimped collar of 1-piece base fits tighter, makes installation easier, and allows for adjustability up to 12/12 pitch without removing turbine. Extra-large flashing and head with included bottom ring for easier installation and better weather protection. Double ribbed vanes, with convex top, direct even wind-driven rain away from the unit. Dade County/Texas Dept. of Insurance Approved. Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. Permanently lubricated track system, upper and lower stainless steel ball bearings prevents metal-to-metal contact, encased to help prevent dirt, dust, sand, and other foreign materials from damaging bearings for long life, less friction, smoother spin, and wear resistance. Heavy-duty steel spider braces and case-hardened steel shaft for long-lasting strength/durability. Simple, mechanically-locked, 2-piece head/base for faster, easier installation. Pre-punched bottom/crimped collar of 1-piece base fits tighter, makes installation easier, and allows for adjustability up to 12/12 pitch without removing turbine. Extra-large flashing and head with included bottom ring for easier installation and better weather protection. Double ribbed vanes, with convex top, direct even wind-driven rain away from the unit. Dade County/Texas Dept. of Insurance Approved.
GAF Master Flow GIC12BL Internal Braced Rotary Turbine Ventilator GAF Master Flow GIC12WW Internal Braced Rotary Turbine Ventilator USP Lumber JL24 Standard Joist Hanger
Permanently lubricated track system, upper and lower stainless steel ball bearings prevents metal-to-metal contact, encased to help prevent dirt, dust, sand, and other foreign materials from damaging bearings for long life, less friction, smoother spin, and wear resistance. Heavy-duty steel spider braces and case-hardened steel shaft for long-lasting strength/durability. Simple, mechanically-locked, 2-piece head/base for faster, easier installation. Pre-punched bottom/crimped collar of 1-piece base fits tighter, makes installation easier, and allows for adjustability up to 12/12 pitch without removing turbine. Extra-large flashing and head with included bottom ring for easier installation and better weather protection. Double ribbed vanes, with convex top, direct even wind-driven rain away from the unit. Dade County/Texas Dept. of Insurance Approved. Permanently lubricated track system, upper and lower stainless steel ball bearings prevents metal-to-metal contact, encased to help prevent dirt, dust, sand, and other foreign materials from damaging bearings for long life, less friction, smoother spin, and wear resistance. Heavy-duty steel spider braces and case-hardened steel shaft for long-lasting strength/durability. Simple, mechanically-locked, 2-piece head/base for faster, easier installation. Pre-punched bottom/crimped collar of 1-piece base fits tighter, makes installation easier, and allows for adjustability up to 12/12 pitch without removing turbine. Extra-large flashing and head with included bottom ring for easier installation and better weather protection. Double ribbed vanes, with convex top, direct even wind-driven rain away from the unit. Dade County/Texas Dept. of Insurance Approved. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Deckmaster DMP125-10 Hidden Deck Bracket Kit Whirlybird GT12 Rigid Spider Internal Braced Turbine Ventilator USP Lumber MP34 Framing Angle
System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies. For: 3/4" thick boards, composites less than 1-1/8", and any hollowcore composites. Consumer pack includes: 10 brackets, (120) 10 x 1" deck board screws, (110) 8 x 1" joist screws, and a pro bit tip. Permanently lubricated ball bearings that ensures long life and no maintenance; fits roof pitch up to 7/12 pitch; easy installation and reduces winter ice breakup. Turbines are exhaust vents. 0.015" stamped galvanized steel. Features 20" x 20" base and 15-3/4" height. Use for joist/header installations. Does not have tabs. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505; ICBO 5736; DSA PA-076; Dade County, FL 01-0417.11; and  L.A. City RR25303 codes. 18 Gauge.
GAF Master Flow AIC14 Internal Braced Rotary Turbine Ventilator GAF Master Flow GC12E External Braced Rotary Turbine Ventilator GAF Master Flow AIC14WW Internal Braced Rotary Turbine Ventilator
Permanently lubricated track system, upper and lower stainless steel ball bearings prevents metal-to-metal contact, encased to help prevent dirt, dust, sand, and other foreign materials from damaging bearings for long life, less friction, smoother spin, and wear resistance. Heavy-duty steel spider braces and case-hardened steel shaft for long-lasting strength/durability. Simple, mechanically-locked, 2-piece head/base for faster, easier installation. Pre-punched bottom/crimped collar of 1-piece base fits tighter, makes installation easier, and allows for adjustability up to 12/12 pitch without removing turbine. Extra-large flashing and head with included bottom ring for easier installation and better weather protection. Double ribbed vanes, with convex top, direct even wind-driven rain away from the unit. Dade County/Texas Dept. of Insurance Approved. Galvanized construction, externally braced for added strength. Heavy-duty construction ideal for coastal and high wind areas. Simple, 2-piece assembly for faster installation. Permanently lubricated dual bearing system for long lasting performance. Stainless steel ball bearings. 720 CFM air movement. No.GC12E Dade County Approved 02-0524.03. Nos.GC12EF & GC12EWWF Florida Building Code (FBC) Approved FL5027. Permanently lubricated track system, upper and lower stainless steel ball bearings prevents metal-to-metal contact, encased to help prevent dirt, dust, sand, and other foreign materials from damaging bearings for long life, less friction, smoother spin, and wear resistance. Heavy-duty steel spider braces and case-hardened steel shaft for long-lasting strength/durability. Simple, mechanically-locked, 2-piece head/base for faster, easier installation. Pre-punched bottom/crimped collar of 1-piece base fits tighter, makes installation easier, and allows for adjustability up to 12/12 pitch without removing turbine. Extra-large flashing and head with included bottom ring for easier installation and better weather protection. Double ribbed vanes, with convex top, direct even wind-driven rain away from the unit. Dade County/Texas Dept. of Insurance Approved.
Simpson Strong-Tie LSTA Light Duty Strap Tie USP Lumber RT7A Double Plate Hurricane/Seismic Anchor USP Lumber JL26 Standard Joist Hanger
Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
National Nail 1/2X6 Pre-Formed Anchor Bolt FORM CONCRETE FOOT PLASTC 32IN National Nail 3/8X8 Pre-Formed Anchor Bolt
Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Fastest, easiest way to form concrete footings; patented square footing form decreases cycle time, labor and material cost; can be sized, attached to construction tube, placed in excavated hole and backfilled. Can be used with rebar to reinforce footing or column if needed. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete.
Acorn IHW24500 Insulation Support Wire 24 in L USP Lumber RT3A Double Plate Hurricane/Seismic Anchor Marshall JP79 Adjustable Extend-O-Post Jackpost
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. Ties trusses and rafters to top plates either left or right handed. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. G90 galvanizing finish. Requires 8d nails for installation in plate and rafter/truss. Meets ICC-ES ESR-1465 and FL817 codes. 18 Gauge. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension.
Lomanco HUMID Humidistat USP Lumber LSTA12 Light Capacity Strap Tie USP Lumber NP Truss Mending Plate
Allows user to control moisture and humidity levels during colder months. Adjustable to fit individual attic humidity levels. Wires parallel with existing thermostat. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge.
Marshall JP84 Adjustable Extend-O-Post Jackpost GAF Master Flow AIC14BL Internal Braced Rotary Turbine Ventilator USP Lumber JUS28 Double Shear Slant Joist Hanger
Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. Permanently lubricated track system, upper and lower stainless steel ball bearings prevents metal-to-metal contact, encased to help prevent dirt, dust, sand, and other foreign materials from damaging bearings for long life, less friction, smoother spin, and wear resistance. Heavy-duty steel spider braces and case-hardened steel shaft for long-lasting strength/durability. Simple, mechanically-locked, 2-piece head/base for faster, easier installation. Pre-punched bottom/crimped collar of 1-piece base fits tighter, makes installation easier, and allows for adjustability up to 12/12 pitch without removing turbine. Extra-large flashing and head with included bottom ring for easier installation and better weather protection. Double ribbed vanes, with convex top, direct even wind-driven rain away from the unit. Dade County/Texas Dept. of Insurance Approved. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Surface Protection BLDLS38100 Builder Board Hopkins 90110 Comfortable Flip Top Bench Table FLOOR PROTECTOR 38INX100FT HD
Temporary floor protection now repels water, mud, paint, and more. It protects floors from tracked in water and job site spills while allowing moisture and vapors to escape for curing. One roll covers the same area as 10 sheets of masonite. Tough enough to be driven on. 100% recyclable. Make a comfortable, sturdy bench and a table up to 8' long. Just add 2x4 lumber pieces. Flips and locks from a bench to a table in seconds without using tools. Slide lock safely secures and locks in position. Made of maintenance free structural resin. Use only one or slide two Bench Tables together for a full size picnic table. Good for small porches and decks. Assembled unit stands 34"H in the bench position, 31"H in the table position and both with 17.5"H seat. Includes Bench Table legs, hardware and instructions. LUMBER NOT INCLUDED. A contractor strength floor protection roll for your toughest jobs; made from 100 percent recycled newsprint; eco-friendly; breathable to protect new and existing wood, concrete, stone, tile, linoleum, epoxy, vinyl composition tile and most other floor types; new innovative liquid repellent technology protects against paint, mud, water and more; earns up to 2 LEED points on projects seeking USGBC certification; safe for all surfaces; forklift strong; made in the USA.
USP Lumber RT Hurricane/Seismic Anchor Whirlybird B I B-14B Rigid Spider Turbine Ventilator Whirlybird B I B-14 Rigid Spider Turbine Ventilator
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Permanently lubricated upper and lower ball bearing system that ensures long life and no maintenance; all-aluminum rust free construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH. Easy installation and reduces winter ice buildup.  Forever guarantee - residential use. BIB12 Dade County Approved 16-0510.26. BIB14 Miami Dade County Approved 15-0831.08. BIB12  features a 20" x 20" base and 17-1/4" height. BIB14 features a 22" x 22" base and 20" height. Turbines are exhaust vents. Permanently lubricated upper and lower ball bearing system that ensures long life and no maintenance; all-aluminum rust free construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH. Easy installation and reduces winter ice buildup.  Forever guarantee - residential use. BIB12 Dade County Approved 16-0510.26. BIB14 Miami Dade County Approved 15-0831.08. BIB12  features a 20" x 20" base and 17-1/4" height. BIB14 features a 22" x 22" base and 20" height. Turbines are exhaust vents.
USP Lumber PCP Post Cap National Nail 1/2X8 Pre-Formed Anchor Bolt CMC PIN04N018 Non-Graded Rebar Pin
Seamless, keeps water off post tops to protect wood from moisture damage. Corrosion-proof and paintable. Requires one 8d HDG or 10d HDG nail for installation. 3-5/8"W - For 4 x 4 Post/Column. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Reinforced bar, commonly used in concrete and masonry structures.
Whirlybird B I B-12 Rigid Spider Turbine Ventilator National Nail AG5810 Pre-Formed Anchor Bolt National Nail AG5808 Pre-Formed Anchor Bolt
Permanently lubricated upper and lower ball bearing system that ensures long life and no maintenance; all-aluminum rust free construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH. Easy installation and reduces winter ice buildup.  Forever guarantee - residential use. BIB12 Dade County Approved 16-0510.26. BIB14 Miami Dade County Approved 15-0831.08. BIB12  features a 20" x 20" base and 17-1/4" height. BIB14 features a 22" x 22" base and 20" height. Turbines are exhaust vents. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete.
GAF Master Flow R50A Square Top Roof Louver USP Lumber JL28 Standard Joist Hanger USP Lumber RT8A Double Plate Hurricane/Seismic Anchor
Square-top metal utility vent; recommended for kitchen duct outlets and bathroom fan exhausts as well as ventilation; large capacity: full 50 square inches of net free ventilating area (NFA) per vent; versatile, available with square throat in heavy duty aluminum; easy to install, pre-drilled nail holes with extra wide flashing area. CSA listed. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber ST1-TZ Mud Sill Anchor GAF Master Flow IR65G Slant Back Roof Louver USP Lumber JA1 Joist Angle
For securing mudsills and framing into concrete slabs or poured stemwalls. Not for block installation or securing concrete sections together between cold joints. Features prebent base flange for proper anchoring into concrete. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets  NER 530 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. High impact resin. Scratch, crush, and dent resistant, with UV inhibitors to keep consistent color. 12 percent larger flashing with pre-drilled nail holes, and a built-in screen to deter birds and rodents and prevent clogging. Slant back design to prevent weather infiltration especially in deep slope applications. Hood is snapped in place rather than tacked to reduce the chance of blow-off. 11-3/4" x 10-3/4" opening, 20-1/4" x 18" flashing, 5-7/8"H. 65 square inches of net free ventilating area. CSA Listed. Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge.
USP Lumber JA1-TZ Framing Angle U-CLIP 2X-2X TRIPLE ZINC      Whirlybird B I B-12WB Rigid Spider Turbine Ventilator
Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge. A clip connects a 2x wood member to the face of another wood member; 20 gauge; G-185 galvanizing finish; requires (6) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included. Permanently lubricated upper and lower ball bearing system that ensures long life and no maintenance; all-aluminum rust free construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH. Easy installation and reduces winter ice buildup.  Forever guarantee - residential use. BIB12 Dade County Approved 16-0510.26. BIB14 Miami Dade County Approved 15-0831.08. BIB12  features a 20" x 20" base and 17-1/4" height. BIB14 features a 22" x 22" base and 20" height. Turbines are exhaust vents.
Whirlybird B I B-12BR Rigid Spider Turbine Ventilator Whirlybird B I B-12B Rigid Spider Turbine Ventilator Lomanco PVMTR Replacement Motor
Permanently lubricated upper and lower ball bearing system that ensures long life and no maintenance; all-aluminum rust free construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH. Easy installation and reduces winter ice buildup.  Forever guarantee - residential use. BIB12 Dade County Approved 16-0510.26. BIB14 Miami Dade County Approved 15-0831.08. BIB12  features a 20" x 20" base and 17-1/4" height. BIB14 features a 22" x 22" base and 20" height. Turbines are exhaust vents. Permanently lubricated upper and lower ball bearing system that ensures long life and no maintenance; all-aluminum rust free construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH. Easy installation and reduces winter ice buildup.  Forever guarantee - residential use. BIB12 Dade County Approved 16-0510.26. BIB14 Miami Dade County Approved 15-0831.08. BIB12  features a 20" x 20" base and 17-1/4" height. BIB14 features a 22" x 22" base and 20" height. Turbines are exhaust vents. Replacement motor (model FO510B2944) for the LomanCool 2000/1800 power vent.  Replaces  previous motors with the following model numbers: AO416B2059, AO510B2389 and FO510B2497. A universal mounting hardware kit comes in the box with each motor. Motor replacement does not include blade, conduit or thermostat. Motor specifications: 3.4 Amps, 1/10 HP, 1100 RPM and 120 Volts.
USP Lumber KHL33 Heavy Joist Angle USP Lumber PL4 Protection Plate National Nail AG06 Pre-Formed Anchor Bolt
Designed for heavy-duty reinforcement of 90 degree framing intersections. USP primer finish. Requires (2) 5/8" bolts for installation. Meets ICBO 2725, L.A. City RR 25104. 7 Gauge. Easy-to-install for protecting plumbing and power or communication wiring from screw or nail penetration. Conforms to National Electric Code. 16 Gauge - 1/16" Thickness. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete.
National Nail AG08 Pre-Formed Anchor Bolt Whirlybird B I B-14BR Rigid Spider Turbine Ventilator Whirlybird B I B-14WB Rigid Spider Turbine Ventilator
Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Permanently lubricated upper and lower ball bearing system that ensures long life and no maintenance; all-aluminum rust free construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH. Easy installation and reduces winter ice buildup.  Forever guarantee - residential use. BIB12 Dade County Approved 16-0510.26. BIB14 Miami Dade County Approved 15-0831.08. BIB12  features a 20" x 20" base and 17-1/4" height. BIB14 features a 22" x 22" base and 20" height. Turbines are exhaust vents. Permanently lubricated upper and lower ball bearing system that ensures long life and no maintenance; all-aluminum rust free construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH. Easy installation and reduces winter ice buildup.  Forever guarantee - residential use. BIB12 Dade County Approved 16-0510.26. BIB14 Miami Dade County Approved 15-0831.08. BIB12  features a 20" x 20" base and 17-1/4" height. BIB14 features a 22" x 22" base and 20" height. Turbines are exhaust vents.
Whirlybird BEB-12 Rigid Spider External Braced Turbine Ventilator Whirlybird BEB-12B Rigid Spider External Braced Turbine Ventilator Marshall JP84HD Adjustable Extend-O-Post Jackpost
Permanently lubricated ball bearing system; all-aluminum construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH; easy installation and reduces winter ice breakup. Forever guarantee-residential use only.  BEB12 Miami Dade County Approved 16-0510.26. BEB14 Miami Dade County Approved 15-0831.08. BEB12 features a 20" x 20" base and 17-5/8" height. BEB14 features a 22" x 22" base and 20-3/8" height. Permanently lubricated ball bearing system; all-aluminum construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH; easy installation and reduces winter ice breakup. Forever guarantee-residential use only.  BEB12 Miami Dade County Approved 16-0510.26. BEB14 Miami Dade County Approved 15-0831.08. BEB12 features a 20" x 20" base and 17-5/8" height. BEB14 features a 22" x 22" base and 20-3/8" height. Use for supporting sagging floors, weak beams and warping stairways. 2-1/2" x 14 gauge prime steel inner tubing. 2-3/4" x 14 gauge prime steel outer tubing. 2-1/2" steel collar. 1-1/4" x 6" steel screw. Two 4" x 6" x 7 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension.
USP Lumber JUS28-TZ Double Shear Slant Joint Hanger National Nail 1/2X10 Pre-Formed Anchor Bolt USP Lumber CPB Composite Post Base
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved.
National Nail AG5812 Pre-Formed Anchor Bolt Whirlybird BEB-14B Rigid Spider External Braced Turbine Ventilator Lomanco 730 Slant Back Static Roof Ventilator
Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Permanently lubricated ball bearing system; all-aluminum construction; exclusive vari-pitch base adjusts to 12/12 roof pitch; tested to withstand winds of 110 MPH; easy installation and reduces winter ice breakup. Forever guarantee-residential use only.  BEB12 Miami Dade County Approved 16-0510.26. BEB14 Miami Dade County Approved 15-0831.08. BEB12 features a 20" x 20" base and 17-5/8" height. BEB14 features a 22" x 22" base and 20-3/8" height. Three sides louvered for greater air flow. Large nailing flange. All-aluminum, rust-free construction. Fits all pitched roofs. Weather-tight seamed collar. High profile for increased weather protection and circulation. Prevents roof discoloration. Bird-proof.  30 square inches of net free ventilating area. 12-3/16" x 17-3/4" x 4" overall size. Miami Dade County approved.
Hopkins 90158 Workbench Kit National Nail AG10 Pre-Formed Anchor Bolt USP Lumber NP35 Truss Mending Plate
Create a workbench, worktable or power tool stand. Add 2x4's plywood or particleboard to make a workbench, worktable or power tool stand in any length or width up to 8'L x 4'W. Simple assembly in less than an hour with only powered screwdriver and a saw. Only straight, 90-degree cuts required, no miter or angles. Made of structural resin.  Kit includes: 4 legs, hardware and instructions. LUMBER AND SHELF LINKS NOT INCLUDED. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge.
USP Lumber JUS210 Double Shear Slant Joist Hanger USP Lumber LSTA18 Light Capacity Strap Tie Lomanco 550 Pan Style Static Roof Ventilator
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. All aluminum construction. Includes 8" x 8" perma-coated aluminum screen extended to the edges of the cap. Large nailing flange. Rolled flange on vent stack to prevent weather infiltration. A 550S with a taller throat for use on a shake roofs is available.  50 square inches of net free ventilating area. 15-3/8" x 16-1/2" x 4" overall size.
National Nail 1/2X12 Pre-Formed Anchor Bolt Marshall AC363/3637 Adjustable Round Column Lomanco 730B Slant Back Static Roof Ventilator
Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Three sides louvered for greater air flow. Large nailing flange. All-aluminum, rust-free construction. Fits all pitched roofs. Weather-tight seamed collar. High profile for increased weather protection and circulation. Prevents roof discoloration. Bird-proof.  30 square inches of net free ventilating area. 12-3/16" x 17-3/4" x 4" overall size. Miami Dade County approved.
USP Lumber BL Corner Brace National Nail AG12 Pre-Formed Anchor Bolt USP Lumber TPP24 Prong Mending Plate
Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge.
USP Lumber JL210 Standard Joist Hanger Lomanco 550WB Pan Style Static Roof Ventilator Lomanco 550BR Pan Style Static Roof Ventilator
G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. All aluminum construction. Includes 8" x 8" perma-coated aluminum screen extended to the edges of the cap. Large nailing flange. Rolled flange on vent stack to prevent weather infiltration. A 550S with a taller throat for use on a shake roofs is available.  50 square inches of net free ventilating area. 15-3/8" x 16-1/2" x 4" overall size. All aluminum construction. Includes 8" x 8" perma-coated aluminum screen extended to the edges of the cap. Large nailing flange. Rolled flange on vent stack to prevent weather infiltration. A 550S with a taller throat for use on a shake roofs is available.  50 square inches of net free ventilating area. 15-3/8" x 16-1/2" x 4" overall size.
Lomanco 550B Pan Style Static Roof Ventilator Marshall AC369/3691 Adjustable Round Column STRAP TIE 3-1/4X16IN TRI-ZINC
All aluminum construction. Includes 8" x 8" perma-coated aluminum screen extended to the edges of the cap. Large nailing flange. Rolled flange on vent stack to prevent weather infiltration. A 550S with a taller throat for use on a shake roofs is available.  50 square inches of net free ventilating area. 15-3/8" x 16-1/2" x 4" overall size. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Wide strapping; requires (16) WS15-HDG nails for installation. Meets 110 codes.
GAF Master Flow R50ABL Square Top Roof Louver GAF Master Flow R50ABR Square Top Roof Louver STRAP TIE 3 X 7IN TRIPLE ZINC
Square-top metal utility vent; recommended for kitchen duct outlets and bathroom fan exhausts as well as ventilation; large capacity: full 50 square inches of net free ventilating area (NFA) per vent; versatile, available with square throat in heavy duty aluminum; easy to install, pre-drilled nail holes with extra wide flashing area. CSA listed. Square-top metal utility vent; recommended for kitchen duct outlets and bathroom fan exhausts as well as ventilation; large capacity: full 50 square inches of net free ventilating area (NFA) per vent; versatile, available with square throat in heavy duty aluminum; easy to install, pre-drilled nail holes with extra wide flashing area. CSA listed. Medium capacity; requires (20) 10d x 1-1/2" HDG nails for installation. Meets 130 codes.
HANGER RIDGE RAFTER 18 GAUGE  Marshall AC386 Adjustable Round Column Marshall AC370/3704 Adjustable Round Column
Supports rafter pitches up to 7:12 (30?). Nesting top flange for installation on 2x support beams. Use all specified fasteners. The rafter end at the ridge must be plumb cut to achieve published loads. Optional diamond nail holes can be used to faster RR to end of rafter before settling rafter into place. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145.
Marshall AC373/3737 Adjustable Round Column CMC PIN03NO18 Graded Rebar Pin USP Lumber JUS24 Double Shear Slant Joist Hanger
3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Reinforced bar, commonly used in concrete and masonry structures. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Marshall AC390 Adjustable Round Column VENT ROOF MOUNT 1000CFM MILL  Marshall AC376/3760 Adjustable Round Column
3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145.
USP Lumber KNS1 Protection Plate CMC PIN04N024 Non-Graded Rebar Pin Marshall AC379/3791 Adjustable Round Column
Easy to install for protecting plumbing and power or communication wiring from screw or nail penetration. 16 gauge, 1/16" thick. Conforms to National Electric Code. Reinforced bar, commonly used in concrete and masonry structures. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145.
USP Lumber T6 T-Post Strap USP Lumber ST12 Strap Tie USP Lumber TPP Truss Mending Plate
Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation. Connects wood framing to resist tension forces. G90 galvanizing finish. ST Medium-duty series require 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. 16 Gauge. Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge.
GAF Master Flow SSB960ABL Slant Back Roof Louver VENT ROOF 1000CFM WEATHER WOOD VENT ROOF MOUNT 1000CFM BLACK
Aluminum material resists rust. Fully enclosed hood to help prevent rodent/insect infiltration and leaf/pine needle clogging. Embossed finish hides scratches and resists wear. Larger flashing with pre-drilled nail holes makes installation easier, helps prevent leaks. 9-7/8" opening; 16" x 201/2 flashing dimension. 60 sq. in. of net free ventilating area per vent. Dade County Approved. Florida Building Code (FBC) Approved for specified SKUs. CSA listed. Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation. Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation.
Marshall AC380/3804 Adjustable Round Column GAF Master Flow SSB960A Slant Back Roof Louver GAF Master Flow SSB960ABR Slant Back Roof Louver
3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Aluminum material resists rust. Fully enclosed hood to help prevent rodent/insect infiltration and leaf/pine needle clogging. Embossed finish hides scratches and resists wear. Larger flashing with pre-drilled nail holes makes installation easier, helps prevent leaks. 9-7/8" opening; 16" x 201/2 flashing dimension. 60 sq. in. of net free ventilating area per vent. Dade County Approved. Florida Building Code (FBC) Approved for specified SKUs. CSA listed. Aluminum material resists rust. Fully enclosed hood to help prevent rodent/insect infiltration and leaf/pine needle clogging. Embossed finish hides scratches and resists wear. Larger flashing with pre-drilled nail holes makes installation easier, helps prevent leaks. 9-7/8" opening; 16" x 201/2 flashing dimension. 60 sq. in. of net free ventilating area per vent. Dade County Approved. Florida Building Code (FBC) Approved for specified SKUs. CSA listed.
GAF Master Flow SSB960AWW Slant Back Roof Louver GAF Master Flow SSB960AW Slant Back Roof Louver Marshall AC383/3837 Adjustable Round Column
Aluminum material resists rust. Fully enclosed hood to help prevent rodent/insect infiltration and leaf/pine needle clogging. Embossed finish hides scratches and resists wear. Larger flashing with pre-drilled nail holes makes installation easier, helps prevent leaks. 9-7/8" opening; 16" x 201/2 flashing dimension. 60 sq. in. of net free ventilating area per vent. Dade County Approved. Florida Building Code (FBC) Approved for specified SKUs. CSA listed. Aluminum material resists rust. Fully enclosed hood to help prevent rodent/insect infiltration and leaf/pine needle clogging. Embossed finish hides scratches and resists wear. Larger flashing with pre-drilled nail holes makes installation easier, helps prevent leaks. 9-7/8" opening; 16" x 201/2 flashing dimension. 60 sq. in. of net free ventilating area per vent. Dade County Approved. Florida Building Code (FBC) Approved for specified SKUs. CSA listed. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145.
USP Lumber JUS24-TZ Double Shear Slant Joint Hanger USP Lumber RT15 Double Plate Hurricane/Seismic Anchor USP Lumber PB66-6TZ 1-Piece Post Cap 18 ga T
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H. For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber PB 2-Piece Split Post Cap USP Lumber MPA1 Framing Angle GAF Master Flow RT65G Square Top Roof Louver
For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Scratch, dent and crush resistant high impact resin plastic. 10" x 10" opening; 17-5/16" x 16-13/16" flashing. 50 square inches of net free ventilating area. CSA listed.
GAF Master Flow RT65BR Square Top Roof Louver GAF Master Flow RT65BL Square Top Roof Louver GAF Master Flow RT65WW Square Top Roof Louver
Scratch, dent and crush resistant high impact resin plastic. 10" x 10" opening; 17-5/16" x 16-13/16" flashing. 50 square inches of net free ventilating area. CSA listed. Scratch, dent and crush resistant high impact resin plastic. 10" x 10" opening; 17-5/16" x 16-13/16" flashing. 50 square inches of net free ventilating area. CSA listed. Scratch, dent and crush resistant high impact resin plastic. 10" x 10" opening; 17-5/16" x 16-13/16" flashing. 50 square inches of net free ventilating area. CSA listed.
GAF Master Flow IR61 Super Low Profile Slant Back Roof Louver ANGLE 2X-2X TRIPLE ZINC 16GA  USP Lumber RS150 Coiled Strap
Just 2"H for better appearance. Injection-molded, high-impact resin construction for long life. Colors complement most roofs. Pre-drilled nail holes make installation easier. 11-3/4" x 9-3/4" opening, 18-1/2" x 17-1/2" flashing, 4-1/4"H, 37 sq.in. of net free ventilating area. An angle connects two 2x wood members at 90? angles; G185 galvanizing finish; requires (8) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included. Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Lomanco 135B Pan Style Static Roof Ventilator Lomanco 135WB Pan Style Static Roof Ventilator Lomanco 135BR Pan Style Static Roof Ventilator
Weather-shielding rain guard for maximum weather protection. 8" x 8" aluminum screen attached. 144 square inches of net free ventilating area. 11-0602.02 Miami Dade County approved. 20" x 23" x 7-3/4" overall size. Weather-shielding rain guard for maximum weather protection. 8" x 8" aluminum screen attached. 144 square inches of net free ventilating area. 11-0602.02 Miami Dade County approved. 20" x 23" x 7-3/4" overall size. Weather-shielding rain guard for maximum weather protection. 8" x 8" aluminum screen attached. 144 square inches of net free ventilating area. 11-0602.02 Miami Dade County approved. 20" x 23" x 7-3/4" overall size.
Lomanco 135 Pan Style Static Roof Ventilator USP Lumber JUS26 Double Shear Slant Joist Hanger USP Lumber FB24-TZ Fence Bracket
Weather-shielding rain guard for maximum weather protection. 8" x 8" aluminum screen attached. 144 square inches of net free ventilating area. 11-0602.02 Miami Dade County approved. 20" x 23" x 7-3/4" overall size. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Provides stronger fence connections and simplifies fence assembly. Can be installed before posts are set to help ensure uniform spacing and alignment. Requires five 6d HDG fasteners for rails and three 8d HDG fasteners for posts.
USP Lumber JUS26-TZ Double Shear Slant Joint Hanger USP Lumber RT Hurricane/Seismic Anchor USP Lumber LSTA24 Light Capacity Strap Tie
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber MPA1 Framing Angle Lomanco 750WB Slant Back Static Roof Ventilator VENT ROOF 1250CFM WEATHER WOOD
Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Three sides louvered for greater air flow. Large nailing flange. All-aluminum, rust-free construction. Fits all pitched roofs. Weather-tight seamed collar. High profile for increased weather protection and circulation. Prevents roof discoloration. Bird-proof. A Model 700 with a neoprene damper installed for use as a kitchen/bathroom exhaust is available.  50 square inches of net free ventilating area. 16" x 20-5/16" x 5" overall size. Miami Dade County approved. Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation.
VENT ROOF MOUNT 1250CFM BLACK USP Lumber JUS210-TZ Double Shear Slant Joint Hanger Lomanco 750 Slant Back Static Roof Ventilator
Pre-wired roof mount attic vent and thermostat control; helps exhaust large amounts of hot and humid air from your attic; helps protect your roofing system and promotes your home's energy efficiency; energy-efficient PSC (permanent-split capacitor); includes internal heavy-duty screen which helps prevent animal infestation. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Three sides louvered for greater air flow. Large nailing flange. All-aluminum, rust-free construction. Fits all pitched roofs. Weather-tight seamed collar. High profile for increased weather protection and circulation. Prevents roof discoloration. Bird-proof. A Model 700 with a neoprene damper installed for use as a kitchen/bathroom exhaust is available.  50 square inches of net free ventilating area. 16" x 20-5/16" x 5" overall size. Miami Dade County approved.
USP Lumber JUS26-2 Double Shear Slant Support Joist Hanger USP Lumber SFP30 Fence Post Connector CMC PIN03N024 Rebar Pin
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Install wooden posts permanently or temporarily without digging.  For heavy-duty applications such as long runs of fencing, corner and gate posts, larger wooden gym sets, detached patio decking, wooden sidewalks, seasonal docks, and more. Removable Forcefit clamps and 2-piece construction, increases unit strength and eliminates welds which are potential weak spots. Reverse spike blades offer lateral soil resistance, increased stability, and allows driving without rotating for easy post alignment. Welded steel construction with high tech baked-on finish, rust resistant and 100% environmentally safe. Application information and installation instructions labeled on each. Green Commission finish. 13 Gauge - For 4 x 4 Posts. Reinforced bar, commonly used in concrete and masonry structures.
Lomanco 750-SWB Slant Back Static Roof Ventilator USP Lumber NP37 Truss Mending Plate USP Lumber T6-TZ T-Post Strap
Three sides louvered for greater air flow. Large nailing flange. All-aluminum, rust-free construction. Fits all pitched roofs. Weather-tight seamed collar. High profile for increased weather protection and circulation. Prevents roof discoloration. Bird-proof. A Model 700 with a neoprene damper installed for use as a kitchen/bathroom exhaust is available.  50 square inches of net free ventilating area. 16" x 20-5/16" x 5" overall size. Miami Dade County approved. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation.
Lomanco 750B Slant Back Static Roof Ventilator Lomanco 750BR Slant Back Static Roof Ventilator USP Lumber CPB Composite Post Base
Three sides louvered for greater air flow. Large nailing flange. All-aluminum, rust-free construction. Fits all pitched roofs. Weather-tight seamed collar. High profile for increased weather protection and circulation. Prevents roof discoloration. Bird-proof. A Model 700 with a neoprene damper installed for use as a kitchen/bathroom exhaust is available.  50 square inches of net free ventilating area. 16" x 20-5/16" x 5" overall size. Miami Dade County approved. Three sides louvered for greater air flow. Large nailing flange. All-aluminum, rust-free construction. Fits all pitched roofs. Weather-tight seamed collar. High profile for increased weather protection and circulation. Prevents roof discoloration. Bird-proof. A Model 700 with a neoprene damper installed for use as a kitchen/bathroom exhaust is available.  50 square inches of net free ventilating area. 16" x 20-5/16" x 5" overall size. Miami Dade County approved. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved.
Lomanco 750-GSB Slant Back Static Roof Ventilator Lomanco 750-GSBR Slant Back Static Roof Ventilator Lomanco 750-GSWB Slant Back Static Roof Ventilator