Home > HARDWARE > CONSTRUCTION HARDWARE > VENTILATION PRODUCTS > UTILILTY VENTS / EXHAUST VENTS
Choose a sub category:
ROOF VENTILATORS ROOF VENTILATORS POWER ROOF VENTILATORS
POWER ROOF VENTILATORS RIDGE VENTS RIDGE VENTS
GABLE VENTS GABLE VENTS POWER GABLE VENTS
POWER GABLE VENTS EAVE VENTS EAVE VENTS
SIDING VENTS SIDING VENTS UTILILTY VENTS / EXHAUST VENTS
UTILILTY VENTS / EXHAUST VENTS FOUNDATION VENTS FOUNDATION VENTS
Sort By:
1
USP Lumber JL26IF-TZ Standard Invert Flange Joist Hanger USP Lumber JDS24 Double Shear Saddle Purlin Hanger USP Lumber JL28IF-TZ Standard Invert Flange Joist Hanger
Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Designed for quick installation of purlins between rafters, joists or trusses in post and beam structures. One-piece construction assures a consistent flush fit between purlin and joist or rafter. A reinforced "double lap" seat boosts the load capacity of this heavy-duty purlin hanger. Requires (4) 10d x 1-1/2" nails for header and (4) 10d" nails for each purlin. Features a 1-9/16" top fold; pending IAPMO-ES evaluation. Speed prongs designed to temporarily position hangers on headers for more convenient nail fastening. G-185 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JUS210-2TZ Double Shear Slant Joint Hanger Vestal 226 Brick Lintel Vestal 230 Brick Lintel
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA.
USP Lumber SKH28R-TZ Skewed Left Joist Hanger USP Lumber SKH28L-TZ Skewed Left Joist Hanger Vestal 236 Brick Lintel
Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA.
Builders Edge 140037079001 Scallop Exhaust Ventilator Vestal 240 Brick Lintel Vestal 246 Brick Lintel
For side walls with patented exhaust flaps which stay closed when not in use; durable, maintenance free, U.V. stabilized and constructed with color molded-through so they won't scratch, flake or fade; comes complete with 8" aluminum tube (4" diameter); optional: small animal guard sold separately; net free area 12 sq. inches; Limited Lifetime warranty. Made in USA. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA.
Builders Edge 140016774001 Hooded Ventilator Marshall JP16 Adjustable Extend-O-Post Jackpost ROD CHAIR REBAR NO2 MTL
ROD CHAIR REBAR NO2 MTL
Our Price: $24.84
Classic design and function for venting air through side walls; durable, maintenance-free, U.V. stabilized and constructed with color molded-through so they won't scratch, flake or fade; built-in concealed exhaust flap stays closed when not in use; net free area 12 sq. inches; locking positions: .75", 1" and 1.25"; fitted with 4" exhaust pipe and pipe length 8"; animal guards and wire screen sold separately; Limited Lifetime warranty. Made in USA. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. Used to support rebar rods when pouring concrete foundation or slab.
Builders Edge 140057575001 Intake/Exhaust Vent Billy Penn 8201 Triple Rod Chair Vestal 250 Brick Lintel
Use for venting bathroom and kitchen exhaust fans; not for use as dryer or furnace vent;  durable, maintenance free, U.V. stabilized and constructed with color molded-through so they won't scratch, flake or fade; full fiberglass screening for complete insect protection; net free area 12 sq. inch; Limited Lifetime warranty. Made in USA. Used to hold rebar off grade and centered in the foundation trench. Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA.
ANGLE 2X4IN TRIPLE ZINC 12GA  Easy Heat ADKS Fixed Resistance Roof and Gutter De-Icing Kit Marshall JP36 Adjustable Extend-O-Post Jackpost
Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong. Roof and Gutter Deicing Cable prevents costly damage to roofs caused by ice formation and snow accumulation in gutters, downspouts, and roof valleys. Can be applied anywhere melting snow and ice can refreeze and penetrate roof surface causing leaks and related damage. Versatile design and rugged waterproof construction adapts to most roof and gutter configurations. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension.
Vestal 260 Brick Lintel Easy Heat ADKS Fixed Resistance Roof and Gutter De-Icing Kit Marshall JP55 Adjustable Extend-O-Post Jackpost
Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA. Roof and Gutter Deicing Cable prevents costly damage to roofs caused by ice formation and snow accumulation in gutters, downspouts, and roof valleys. Can be applied anywhere melting snow and ice can refreeze and penetrate roof surface causing leaks and related damage. Versatile design and rugged waterproof construction adapts to most roof and gutter configurations. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension.
Builders Edge 140056774001 Hooded Ventilator Acorn BC214 Rod Chair ANGLE 2X6IN TRIPLE ZINC 12GA
Classic design and function for venting air through side walls; durable, maintenance-free, U.V. stabilized and constructed with color molded-through so they won't scratch, flake or fade; built-in concealed exhaust flap stays closed when not in use; net free area 25 sq. inches; locking positions: .75", 1" and 1.25"; fitted with 6" exhaust pipe and pipe length 8-1/10"; wire screen included; Limited Lifetime warranty. Made in USA. Support rebar in concrete slabs and foundations. Designed to fit both 3/8" and 1/2" rebar. Flat base design adds to stability of reinforcing while pouring concrete. Bag of 500. Provides a 90? connection for medium/heavy duty applications; stronger than angled nailing or screw fastening; help ensure joints are consistently straight and strong.
Vestal 270 Brick Lintel USP Lumber JL24 Standard Joist Hanger DE-ICING CABLE 150W 30FT KIT
Unique forming process develops high cross strength. Ample load-bearing capacity. Stiff in service. Free from sagging or buckling. All lintels should be shored until mortar has cured. Coated with black corrosion-resistant paint. Made in USA. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. De-icing cable kit prevents winter damage to roof, gutters, and downspouts.
USP Lumber MP34 Framing Angle USP Lumber RT7A Double Plate Hurricane/Seismic Anchor USP Lumber JL26 Standard Joist Hanger
Use for joist/header installations. Does not have tabs. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505; ICBO 5736; DSA PA-076; Dade County, FL 01-0417.11; and  L.A. City RR25303 codes. 18 Gauge. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
National Nail 1/2X6 Pre-Formed Anchor Bolt National Nail 3/8X8 Pre-Formed Anchor Bolt Frost King RC Roof De-Icing Cable With Shingle Clips
Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Pre-assembled ready to install, keeps gutters and downspouts flowing, 120v, 7 watts per ft.
USP Lumber RT3A Double Plate Hurricane/Seismic Anchor Marshall JP79 Adjustable Extend-O-Post Jackpost DE-ICING CABLE 300W 60FT KIT
Ties trusses and rafters to top plates either left or right handed. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. G90 galvanizing finish. Requires 8d nails for installation in plate and rafter/truss. Meets ICC-ES ESR-1465 and FL817 codes. 18 Gauge. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension. De-icing cable kit prevents winter damage to roof, gutters, and downspouts.
USP Lumber NP Truss Mending Plate Easy Heat ADKS Fixed Resistance Roof and Gutter De-Icing Kit Marshall JP84 Adjustable Extend-O-Post Jackpost
Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Roof and Gutter Deicing Cable prevents costly damage to roofs caused by ice formation and snow accumulation in gutters, downspouts, and roof valleys. Can be applied anywhere melting snow and ice can refreeze and penetrate roof surface causing leaks and related damage. Versatile design and rugged waterproof construction adapts to most roof and gutter configurations. Use for supporting sagging floors, weak beams and warping stairways. 2-1/4" x 15 gauge prime steel inner tubing. 2-1/2" x 15 gauge prime steel outer tubing. 2-1/4" steel collar. 1" x 6" steel screw. Two 4" x 4" x 10 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension.
Billy Penn 8200 Double Rod Chair USP Lumber JUS28 Double Shear Slant Joist Hanger Acorn BC314 Rod Chair
Used to hold rebar off grade and centered in the foundation trench. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Support rebar in concrete slabs and foundations. Designed to fit both 3/8" and 1/2" rebar. Flat base design adds to stability of reinforcing while pouring concrete. Bag of 500.
USP Lumber RT Hurricane/Seismic Anchor National Nail 1/2X8 Pre-Formed Anchor Bolt National Nail AG5810 Pre-Formed Anchor Bolt
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete.
National Nail AG5808 Pre-Formed Anchor Bolt USP Lumber JL28 Standard Joist Hanger USP Lumber RT8A Double Plate Hurricane/Seismic Anchor
Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber ST1-TZ Mud Sill Anchor USP Lumber JA1 Joist Angle USP Lumber JA1-TZ Framing Angle
For securing mudsills and framing into concrete slabs or poured stemwalls. Not for block installation or securing concrete sections together between cold joints. Features prebent base flange for proper anchoring into concrete. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets  NER 530 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge. Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge.
U-CLIP 2X-2X TRIPLE ZINC      Easy Heat ADKS Fixed Resistance Roof and Gutter De-Icing Kit USP Lumber KHL33 Heavy Joist Angle
A clip connects a 2x wood member to the face of another wood member; 20 gauge; G-185 galvanizing finish; requires (6) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included. Roof and Gutter Deicing Cable prevents costly damage to roofs caused by ice formation and snow accumulation in gutters, downspouts, and roof valleys. Can be applied anywhere melting snow and ice can refreeze and penetrate roof surface causing leaks and related damage. Versatile design and rugged waterproof construction adapts to most roof and gutter configurations. Designed for heavy-duty reinforcement of 90 degree framing intersections. USP primer finish. Requires (2) 5/8" bolts for installation. Meets ICBO 2725, L.A. City RR 25104. 7 Gauge.
National Nail AG06 Pre-Formed Anchor Bolt National Nail AG08 Pre-Formed Anchor Bolt Marshall JP84HD Adjustable Extend-O-Post Jackpost
Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Use for supporting sagging floors, weak beams and warping stairways. 2-1/2" x 14 gauge prime steel inner tubing. 2-3/4" x 14 gauge prime steel outer tubing. 2-1/2" steel collar. 1-1/4" x 6" steel screw. Two 4" x 6" x 7 gauge steel plates. 7" turning handle. Grooved pin and plain pin. Flow coated with red corrosion-resistant paint. Packed with instructions. UPC symbol on carton. Maximum load capacity obtained at lowest extension.
USP Lumber JUS28-TZ Double Shear Slant Joint Hanger Frost King RC Roof De-Icing Cable With Shingle Clips National Nail 1/2X10 Pre-Formed Anchor Bolt
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Pre-assembled ready to install, keeps gutters and downspouts flowing, 120v, 7 watts per ft. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete.
Easy Heat ADKS Fixed Resistance Roof and Gutter De-Icing Kit National Nail AG5812 Pre-Formed Anchor Bolt National Nail AG10 Pre-Formed Anchor Bolt
Roof and Gutter Deicing Cable prevents costly damage to roofs caused by ice formation and snow accumulation in gutters, downspouts, and roof valleys. Can be applied anywhere melting snow and ice can refreeze and penetrate roof surface causing leaks and related damage. Versatile design and rugged waterproof construction adapts to most roof and gutter configurations. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete.
USP Lumber NP35 Truss Mending Plate USP Lumber JUS210 Double Shear Slant Joist Hanger National Nail 1/2X12 Pre-Formed Anchor Bolt
Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete.
Marshall AC363/3637 Adjustable Round Column USP Lumber BL Corner Brace National Nail AG12 Pre-Formed Anchor Bolt
3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge. Pre-formed bolt designed for anchoring to concrete in all construction work. Hold securely and permanently because of the angle design. Designed for all types of anchoring to poured concrete.
DE-ICING CABLE 500W 100FT KIT USP Lumber TPP24 Prong Mending Plate USP Lumber JL210 Standard Joist Hanger
De-icing cable kit prevents winter damage to roof, gutters, and downspouts. Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Marshall AC369/3691 Adjustable Round Column HANGER RIDGE RAFTER 18 GAUGE  Marshall AC386 Adjustable Round Column
3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Supports rafter pitches up to 7:12 (30?). Nesting top flange for installation on 2x support beams. Use all specified fasteners. The rafter end at the ridge must be plumb cut to achieve published loads. Optional diamond nail holes can be used to faster RR to end of rafter before settling rafter into place. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145.
Marshall AC370/3704 Adjustable Round Column Marshall AC373/3737 Adjustable Round Column USP Lumber JUS24 Double Shear Slant Joist Hanger
3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Marshall AC390 Adjustable Round Column Marshall AC376/3760 Adjustable Round Column Marshall AC379/3791 Adjustable Round Column
3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145.
USP Lumber TPP Truss Mending Plate Marshall AC380/3804 Adjustable Round Column Marshall AC383/3837 Adjustable Round Column
Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145. 3"OD 11 gauge (0.120 wall). 4" adjustment. Cold rolled steel screw. Turning bar provided with each post. Flow-coated inside and out with red corrosion-resistant paint. Heavy-duty cap and base plates slotted; holes to fit steel or wood beams. Embossed lugs grip posts firmly to avoid slipping. All parts are welded or wired together. Meets IRC and IBC Specifications Report No. CCRR-0145.
USP Lumber JUS24-TZ Double Shear Slant Joint Hanger USP Lumber RT15 Double Plate Hurricane/Seismic Anchor USP Lumber MPA1 Framing Angle
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Easy Heat ADKS Fixed Resistance Roof and Gutter De-Icing Kit DE-ICING CABLE 600W 120FT KIT ANGLE 2X-2X TRIPLE ZINC 16GA
Roof and Gutter Deicing Cable prevents costly damage to roofs caused by ice formation and snow accumulation in gutters, downspouts, and roof valleys. Can be applied anywhere melting snow and ice can refreeze and penetrate roof surface causing leaks and related damage. Versatile design and rugged waterproof construction adapts to most roof and gutter configurations. De-icing cable kit prevents winter damage to roof, gutters, and downspouts. An angle connects two 2x wood members at 90? angles; G185 galvanizing finish; requires (8) USP LumberLok LL915 (#9 x 1-3/8" long) wood screws not included.
USP Lumber JUS26 Double Shear Slant Joist Hanger USP Lumber JUS26-TZ Double Shear Slant Joint Hanger USP Lumber RT Hurricane/Seismic Anchor
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc finish requires 8d HDGnails for installation in plate and rafter/truss and Gold Coat anchor requires N8-GC nails. 1-9/16"W x 2-5/8"H opening. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Contractors charts in the Orgill paper catalog R7 for reference pages. 18 GAUGE - 5-1/4"H.
USP Lumber MPA1 Framing Angle USP Lumber JUS210-TZ Double Shear Slant Joint Hanger Easy Heat RS2 Roof Sentry De-Icing Control
Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Controller for the roof and gutter de-icer cable. Controller requires two conditions to be present before it will energize the roof de-icing cable. It requires cold temperatures and the presence of run-off water from the roof in contact with the sensor wire. If only one of the conditions exists, the control will not turn on the cable. A switch inside the house can control the box.
USP Lumber JUS26-2 Double Shear Slant Support Joist Hanger USP Lumber NP37 Truss Mending Plate USP Lumber TFL2595 Joist Hanger
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1831 codes. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber BL Reinforcement Corner Brace USP Lumber ST2-TZ Mud Sill Anchor LATE MNDG 13/16X3-1/2IN
Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge. For securing mudsills and framing into concrete slabs, poured stemwalls, or concrete block. Not for securing concrete sections together between cold joints. Features prebent base flange for proper anchoring into concrete. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets NER 530 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not for structural use OR use in truss assembly; no load ratings assigned. G90 galvanizing finish. 22 Gauge.
USP Lumber JUS26-2TZ Double Shear Slant Joint Hanger USP Lumber JUS210-2 Double Shear Slant Support Joist Hanger USP Lumber TFL20118 Joist Hanger
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Features 1-1/2" top flange depth that accommodates all header types as well as bact-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1831. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2" nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber JUS28-2 Double Shear Slant Joist Hanger USP Lumber SCA Stair Angle USP Lumber TFL25118 Joist Hanger
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Simplifies stair construction and eliminate the need to calculate and notch stair stringers. Stronger and safer than wood blocking, and the angle and fasteners are hidden from view. Use the SCA9 for single 2x10 stair treads and SCA10 for double 2 x 6 stair treads. Requires 1/4" x 1-1/2" lag bolts. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information on installation, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Features 1-1/2" top flange depth that accommodates all header types as well as back-to-back installations. Features "Seat Cleat" for quick, positive seating. G90 galvanizing finish. Meets ICC-ES ESR-1831 codes. Header requires (6) 10d nails and joist requires (2) 10d x 1-1/2 nails for installation. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber RT10 Double Plate Hurricane/Seismic Anchor USP Lumber CSH-TZ Concealed Stringer Hanger USP Lumber WE44-TZ Wet Post Anchor
Used to tie wood framing members to resist uplift and lateral forces. G90 galvanizing finishing. Requires 8d nails for installation. Meets ICC-ES ESR-1465, FL817 and Dade County, FL 07-0306.10 codes. 18 Gauge. Concealed stair stringer hanger provides a method of connecting a stringer with a hidden hanger. The seat of the hanger is adjustable to match the slope of the stair stringer. Triple Zinc finish. Requires (8) 10d x 1-1/2 HDG nails for header and (5) 10d x 1-1/2 HDG nails for joist. 18 Gauge. Pending IAPMO-ES evaluation. Secures posts to concrete in light-duty and medium-duty applications such as patio covers, carports or decks. Formed, one-piece design includes embossing for additional lateral strength. Not  for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires (2) 1/2" HDG bolts or (12) HDG nails for fastening to post. Meets SBCCI, BOCA - NER 530 & NER 608, ICBO 5700, ICBO 2039, ICBO 5531, FL821, FL822, L.A. City RR 25337, and DSA PA-076 codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber RT16A Double Plate Hurricane/Seismic Anchor USP Lumber A3 Framing Angle USP Lumber SCA Stair Angle
Anchor tie trusses and rafters to top plates and may be used to tie wood framing members to resist uplift and lateral forces. Typical Truss/rafter to double plate installation. Requires Meet ICC-ES ESR-1465 and FL817 codes. Eliminates toenailing and increases strength. Requires 10d x 1-1/2" nails for installation. 1-7/16"W1 X 1-7/16"W2 X 2-3/4"L - 18 GAUGE. Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. Simplifies stair construction and eliminate the need to calculate and notch stair stringers. Stronger and safer than wood blocking, and the angle and fasteners are hidden from view. Use the SCA9 for single 2x10 stair treads and SCA10 for double 2 x 6 stair treads. Requires 1/4" x 1-1/2" lag bolts. Meets ICC-ES ESR-1280, FL11664 and L.A. City RR25749 codes. For additional information on installation, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
USP Lumber JUS26-GC Double Shear Slant Joist Hanger USP Lumber HCPRS Hurricane/Seismic Anchor USP Lumber JDS24-S Double Shear Single Purlin Hanger
Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Used to tie trusses and rafters to top plates, and may be used to tie wood framing members to resist uplift and lateral forces. G90 galvanizing finish. 1-9/16"W opening. Meets ICC-ES ESR-1881, FL821 and L.A. City RR25779 codes. 18 Gauge - 5-1/4"W. Designed for quick installation of purlins between rafters, joists or trusses in post and beam structures. One-piece construction assures a consistent flush fit between purlin and joist or rafter. A reinforced "double lap" seat boosts the load capacity of this heavy-duty purlin hanger. Requires (2) 10d x 1-1/2"nails for header and (2) 10d nails for each purlin. Features a 3/4" top fold; pending IAMPO-ES evaluation.
USP Lumber NP39 Truss Mending Plate USP Lumber THF25112 Joist Hanger USP Lumber LSSH15-TZ Slope/Skew Joist Hanger
Joins flat surfaces of 2 or more wood members. Not for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge. Designed to provide lateral support for the top chords of I-Joists in depths up to 16". G90 galvanizing finish. Meets ICC-ES ESR-1781, FL13285 and L.A. City RR25843 codes. Install 10d x 1-1/2" nails into joist through raised dimple at 45 degree angle. For THF Min, fill all round nail holes. For THF Max, fill all round and diamond holes. For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. Connects rafters to ridge beams in vaulted roof structures; field adjustable to meet a variety of skew and slope applications; slopes to any pitch to 45 degrees up or down and skews up to 45 degrees right or left.  For information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For additional sizing information, visit www.uspconnectors.com. 18 Gauge.
USP Lumber JUS28-2TZ Double Shear Slant Joist Hanger USP Lumber SKH28L Skewed Left Joist Hanger USP Lumber SKH28R Skewed Right Joist Hanger
Double shear nailing for fewer nails and faster installation. Dimples allow for 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade county, FL 11-0510.01 and 07-0419.01 codes. For additional information including allowable loads and fasteners. Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments.
USP Lumber MP9-TZ Framing Angle USP Lumber SKH26R-TZ Skewed Right Joist Hanger USP Lumber SKH26L-TZ Skewed Left Joist Hanger
May be field adjusted by hand from 0 to 135 degrees, giving framers and do-it-yourselfers flexibility in applications. Bend angle only once. G90 galvanized finish. 10d HDG nails required for installation. Meets SBCCI, BOCA - NER 530, ICBO 5700, FL822, L.A. City RR 25337, DSA PA-06 codes. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments.
USP Lumber AC9-TZ Framing Angle USP Lumber AC5-TZ Framing Angle USP Lumber JNP24 Joiner Nail Mending Plate
For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Prong plates with angled, hammer-in prongs. Joins flat surfaces of 2 or more wood members. G90 galvanizing finish. Not intended for structural use OR in truss assembly. No load ratings assigned. 18 Gauge.
USP Lumber JNP28 Joiner Nail Mending Plate USP Lumber AC Framing Angle
Prong plates with angled, hammer-in prongs. Joins flat surfaces of 2 or more wood members. G90 galvanizing finish. Not intended for structural use OR in truss assembly. No load ratings assigned. 18 Gauge. For general-purpose reinforcements of many framing connections. G185 galvanized finish. Can be used in both new construction and retrofit applications. Staggered nail patterns reduce wood splitting and allows installation on both sides of the supported member. Triple Zinc clips require 10d HDG or 16d HDG nails.  Meets ICC-ES ESR-2104, FL820 and L.A. City RR25745 codes. For additional information including allowable loads and number of fasteners, please see USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages.
   
 
1